2,661 research outputs found
Extraction Methods and an Investigation of Drosophila Lipids
In earlier work (8) we extracted lipids from dried, macerated Drosophila melanogaster with ether, but later, working with larger quantities of undried flies, we found that most of the phospholipids were autolyzed. Kates' studies (2) led him to suggest n-propanol or isopropanol for lipid extraction (isopropanol was his later choice (6, 7)). Attempting to meet the requirements discussed above, we developed a new and relatively simple method of extraction employing n-propanol (9), or chloroformmethanol (2:1). The latter proved to be a more useful solvent. The method will be described in detail below, with results of an examination of Drosophila lipids
Phospholipides containing amino acids other than serine. I. Detection
In view of the widespread occurrence of the amino acid-containing lipides and the unique course of their metabolism during development of Drosophila, we have carried out extensive investigations concerned with their isolation and chemical nature. The present report is concerned primarily with techniques and procedures developed to insure removal of non-lipide contaminants from preparations of these lipides
Recommended from our members
Fluorescent optical fibre chemosensor for the detection of mercury
This work aims to develop a stable, compact and portable fibre optic sensing system which is capable of real time detection of the mercury ion (II), Hg2+. A novel fluorescent polymeric material for Hg2+ detection, based on a coumarin derivative (acting as the fluorophore) and an azathia crown ether moiety (acting as the mercury ion receptor), has been designed and synthesized. The material was covalently attached to the distal end of an optical fibre and exhibited a significant increase in fluorescence intensity in response to Hg2+ in the μM concentration range via a photoinduced electron transfer (PET) mechanism. The sensor has also demonstrated a high selectivity for Hg2+ over other metal ions. A washing protocol was identified for sensor regeneration, allowing the probe to be re-used. The approach developed in this work can also be used for the preparation of sensors for other heavy metals
SkyDOT (Sky Database for Objects in the Time Domain): A Virtual Observatory for Variability Studies at LANL
The mining of Virtual Observatories (VOs) is becoming a powerful new method
for discovery in astronomy. Here we report on the development of SkyDOT (Sky
Database for Objects in the Time domain), a new Virtual Observatory, which is
dedicated to the study of sky variability. The site will confederate a number
of massive variability surveys and enable exploration of the time domain in
astronomy. We discuss the architecture of the database and the functionality of
the user interface. An important aspect of SkyDOT is that it is continuously
updated in near real time so that users can access new observations in a timely
manner. The site will also utilize high level machine learning tools that will
allow sophisticated mining of the archive. Another key feature is the real time
data stream provided by RAPTOR (RAPid Telescopes for Optical Response), a new
sky monitoring experiment under construction at Los Alamos National Laboratory
(LANL).Comment: to appear in SPIE proceedings vol. 4846, 11 pages, 5 figure
Recommended from our members
A Fluorescent Optical Fibre Chemosensor for Mercury Detection
A proof-of-concept mercury probe was developed based on covalent attachment of a chemical coating to optical fibre. The sensing element comprised a dansyl derivative and crown ether moiety, acting as fluorophore and metal ion chelator respectively. An ON-OFF type fluorescence (quench) occurred upon binding of mercury ions, via an intramolecular charge transfer mechanism, in aqueous solution in the 909nM-90.9μM (247 ppb -24.7 ppm) concentration range. A washing protocol was identified for sensor regeneration allowing the probe to be re-used
Lessons learned from a peri-urban needle exchange
<p>Abstract</p> <p>Background</p> <p>Injection drug users continue to be at high risk of HIV and HCV. Research has shown that needle exchange programs (NEP) decrease injection frequency, reduce syringe reuse, and reduce needle sharing, though some results have been mixed.</p> <p>Methods</p> <p>This evaluation of a small, peri-urban, legal NEP near Ypsilanti, Michigan describes the operation of the NEP and its clients. It uses interviews conducted with NEP participants between 2003 and 2006, describing the population served by the program, and draws on limited comparisons between matched baseline and follow-up measures as well as aggregate baseline and follow-up comparisons.</p> <p>Results</p> <p>The HIV/AIDS Resource Center (HARC) Harm Reduction NEP serves a diverse population from a wide geographical area. NEP participants at follow-up reused their syringes significantly fewer times before getting new ones, were significantly less likely to report giving another IDU a previously used syringe, and were more likely to clean their skin with alcohol either before or after injecting than the baseline comparison group.</p> <p>Conclusions</p> <p>The limited data presented here suggest that a NEP can be an effective method of harm reduction even in low-volume, non-urban settings and are an important venue for intervention in peri-urban areas.</p
RAPTOR observations of delayed explosive activity in the high-redshift gamma-ray burst GRB 060206
The RAPid Telescopes for Optical Response (RAPTOR) system at Los Alamos
National Laboratory observed GRB 060206 starting 48.1 minutes after gamma-ray
emission triggered the Burst Alert Telescope (BAT) on-board the Swift
satellite. The afterglow light curve measured by RAPTOR shows a spectacular
re-brightening by ~1 mag about 1 h after the trigger and peaks at R ~ 16.4 mag.
Shortly after the onset of the explosive re-brightening the OT doubled its flux
on a time-scale of about 4 minutes. The total R-band fluence received from GRB
060206 during this episode is 2.3e-9 erg/cm2. In the rest frame of the burst (z
= 4.045) this yields an isotropic equivalent energy release of ~0.7e50 erg in
just a narrow UV band 130 +/- 22 nm. We discuss the implications of RAPTOR
observations for untriggered searches for fast optical transients and studies
of GRB environments at high redshift.Comment: Submitted to ApJ Letter
Recommended from our members
A suite of optical fibre-based chemical sensors for environmental monitoring
This paper is to review the research activities at City University London in the development of a suite of optical fibre-based chemical sensors, including pH, humidity and heavy metal sensors, for environmental monitoring
- …