2 research outputs found

    Safety and efficacy of midline catheters versus peripheral intravenous catheters: A pilot randomized controlled trial

    Get PDF
    Background: Despite pervasive need for peripheral intravenous catheters, insertion is often difficult, and approximately two thirds fail prematurely. Midline catheters are an alternative long peripheral catheter, inserted in the upper arm, ideal for patients with difficult access. Aim: The aim of this study is to test feasibility of the protocol and compare the efficacy and safety of midline catheters to peripheral intravenous catheters. Design: A parallel-group, pilot randomized controlled trial of adult medical/surgical hospitalized patients, from a single Australian referral hospital. Methods: Participants with difficult vascular access (≤2 palpable veins) and/or anticipated ≥5 days of peripherally compatible intravenous therapy were recruited between May 2019 and March 2020. Participants were randomized to (1) peripheral intravenous catheter or (2) midline catheter. Primary feasibility outcome measured eligibility, recruitment, protocol adherence, retention and attrition. Primary clinical outcomes measured device insertion failure and post-insertion failure. Results: In total, n = 143 participants (71 peripheral intravenous catheters and 72 midline catheters) were recruited; n = 139 were analysed. Most feasibility criteria were met. Peripheral intravenous catheters had shorter functional dwell time, with higher incidence of post-insertion failure compared to midline catheters. Conclusion: Midline catheters appear to be superior for patients with difficult vascular access or receiving prolonged intravenous therapy; a large, multi-centre trial to confirm findings is feasible

    Innovation in clinical learning for the acute hospital environment: Nursing grand rounds

    Get PDF
    The literature reports that workload factors affect nurses' ability to fully engage in continuing professional development. Hence the work environment in acute care calls for innovative approaches to achieve continuous development of nursing practice and work satisfaction. This study employs a one group pre-test post-test design to test the effectiveness of nursing grand rounds on nursing worklife satisfaction and work environment in an acute surgical ward. The effect of nursing grand rounds was measured using the Nursing Worklife Satisfaction Scale and the Practice Environment Scale. There was no change between pre- and post-test on these measures but trends were evident in some component scores. Statistical results were inconclusive but observational data indicated that nursing grand rounds was found to be feasible, well attended with tested processes for implementation in an acute care environment
    corecore