1,590 research outputs found
The frequency of total use of manual and automatic low-consumption fixtures in the Langford Architecture Building at Texas A&M University
The Energy Policy Act of 1992 mandated that bathroom plumbing fixtures manufactured in the United States after January 1, 1994 meet standards for maximum water consumption. Manufacturers have developed low-consumption valves to meet these standards. The performance of low-consumption fixtures has become an important issue for facilities managers because the water saving by retrofitting low-consumption fixtures is significant. The fixtures in the Langford Architecture Building A, Texas A&M University were used to conduct this study. An acoustic information retrieval system was utilized to collect the sound signals of each fixture and a speech recognition system was utilized to identify which fixture was in use. The data from this study were analyzed to determine whether location of fixture and type of fixtureâÂÂmanual or automaticâÂÂcaused a significant difference in frequency of use
Pseudotumor of the Omentum Associated with Migration of the Ingested Crab-Leg
Foreign body ingestion is not uncommon in clinical practice, and it may occasionally lead to penetration injuries. Emergency physicians and radiologists sometimes fail to obtain complete histories including ingestion and may overlook the possibility of foreign body-induced complications. Herein, we report a case of stomach antrum perforation due to foreign body migration. We were unaware of the patient's history of eating the Korean delicacy "Kanjang-gaejang," which is raw crab seasoned with soy sauce. Several imaging diagnostic modalities had suggested the possibility of a malignant mass in the gastrocolic ligament area. During the operation, a crab leg was discovered as the cause of an intra-abdominal abscess. The patient underwent an antrectomy, a vagotomay, and a transverse colon wedge resection. We present this unusual case of a pseudotumorous lesion caused by ingestion of Kanjang-gaejang
Implementation of batchwise bioscouring of cotton knits
The examination of critical factors determining the performance of bioscouring showed that a short treatment of the fabric at greater than 80°C after pectinase treatment at 60°C was essential for removal of waxes from the fabric as demonstrated by diminished intensities of methylene peaks in FT-IR measurements. Batch-wise bioscouring of cotton knits was carried out several times with post-treatment at 80°C using a rapid dyeing machine. The dye-ability of bioscoured knits was as good as the company's alkaline scoured ones with slightly higher K/S values. Water pollution caused by effluents of bioscouring and alkaline processes were estimated, as well as that due to the input of chemicals and enzymes. Higher BOD:CODCr ratios for enzymes indicated their biodegradable character. After calculation of energy consumption using a simulation program, an economic evaluation of the two processes was done on the basis of one ton production by considering the costs of chemicals and enzyme, water usage, energy consumption and waste water treatment charge
Intra- and inter-hemispheric effective connectivity in the human somatosensory cortex during pressure stimulation
Background: Slow-adapting type I (SA-I) afferents deliver sensory signals to the somatosensory cortex during low-frequency (or static) mechanical stimulation. It has been reported that the somatosensory projection from SA-I afferents is effective and reliable for object grasping and manipulation. Despite a large number of neuroimaging studies on cortical activation responding to tactile stimuli mediated by SA-I afferents, how sensory information of such tactile stimuli flows over the somatosensory cortex remains poorly understood. In this study, we investigated tactile information processing of pressure stimuli between the primary (SI) and secondary (SII) somatosensory cortices by measuring effective connectivity using dynamic causal modeling (DCM). We applied pressure stimuli for 3 s to the right index fingertip of healthy participants and acquired functional magnetic resonance imaging (fMRI) data using a 3T MRI system. Results: DCM analysis revealed intra-hemispheric effective connectivity between the contralateral SI (cSI) and SII (cSII) characterized by both parallel (signal inputs to both cSI and cSII) and serial (signal transmission from cSI to cSII) pathways during pressure stimulation. DCM analysis also revealed inter-hemispheric effective connectivity among cSI, cSII, and the ipsilateral SII (iSII) characterized by serial (from cSI to cSII) and SII-level (from cSII to iSII) pathways during pressure stimulation. Conclusions: Our results support a hierarchical somatosensory network that underlies processing of low-frequency tactile information. The network consists of parallel inputs to both cSI and cSII (intra-hemispheric), followed by serial pathways from cSI to cSII (intra-hemispheric) and from cSII to iSII (inter-hemispheric). Importantly, our results suggest that both serial and parallel processing take place in tactile information processing of static mechanical stimuli as well as highlighting the contribution of callosal transfer to bilateral neuronal interactions in SII.open1
Could Fractional Exhaled Nitric Oxide Test be Useful in Predicting Inhaled Corticosteroid Responsiveness in Chronic Cough? A Systematic Review
© 2016 Background Fractional exhaled nitric oxide (FENO) is a safe and convenient test for assessing T H 2 airway inflammation, which is potentially useful in the management of patients with chronic cough. Objective To summarize the current evidence on the diagnostic usefulness of FENO for predicting inhaled corticosteroid (ICS) responsiveness in patients with chronic cough. Methods A systematic literature review was conducted to identify articles published in peer-reviewed journals up to February 2015, without language restriction. We included studies that reported the usefulness of FENO (index test) for predicting ICS responsiveness (reference standard) in patients with chronic cough (target condition). The data were extracted to construct a 2 × 2 accuracy table. Study quality was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Results We identified 5 original studies (2 prospective and 3 retrospective studies). We identified considerable heterogeneities in study design and outcome definitions, and thus were unable to perform a meta-analysis. The proportion of ICS responders ranged from 44% to 59%. Sensitivity and specificity ranged from 53% to 90%, and from 63% to 97%, respectively. The reported area under the curve ranged from abou t 0.60 to 0.87; however, studies with a prospective design and a lower prevalence of asthma had lower area under the curve values. None measured placebo effects or objective cough frequency. Conclusions We did not find strong evidence to support the use of FENO tests for predicting ICS responsiveness in chronic cough. Further studies need to have a randomized, placebo-controlled design, and should use validated measurement tools for cough. Standardization would facilitate the development of clinical evidence
Cough persistence in adults with chronic cough: a 4-year retrospective cohort study
BackgroundThere is very limited evidence regarding long-term prognosis of chronic cough. We examined longitudinal outcomes among patients with chronic cough, and explored predictors of cough persistence.MethodsA retrospective cohort was constructed of adults who had newly visited a specialist cough clinic in 2012–2013. All had undergone systematic investigation for chronic cough. The Hull Airway Reflux Questionnaire (HARQ) was administered to assess reflux cough symptoms. A follow-up survey was conducted in 2016–2017 to assess cough persistence.ResultsFrom 418 candidates, 323 participated in the follow-up study; main analyses focused on patients with chronic persistent cough (n=64; 19.8%) and remitted cough (n=193; 59.8%). Compared with remitted cough, chronic persistent cough group had more family history of chronic cough (17.2% vs. 4.7%, p=0.001) and cold air-sensitive cough (62.5% vs. 44.6%, p=0.013). The total HARQ score did not differ; however, two items (cough with eating and cough with certain foods) scored significantly higher in chronic persistent cough. In multivariate analyses, a family history of chronic cough (adjusted odds ratio 4.27 [95% confidence interval 1.35-9.89]), cold air-sensitive cough (2.01 [1.09-3.73]), and cough with eating (1.22 [1.02–1.45]) were associated with chronic persistent cough at 4 years.Conclusions Cough persists in about 20% of patients after 4 years following systematic assessment and treatments. Several cough characteristics, such as family history, cold air-sensitivity, or reflux cough, may be associated with cough persistence. Larger cohort studies are warranted to further understand long-term prognosis and confirm predictors of persistence in patients with chronic cough
- …