1,012 research outputs found

    A Methodology for Three-Dimensional Quantification of Anterior Tooth Width

    Get PDF
    The use of cone-beam computed tomography (CBCT) technology has been shown to be more accurate in measuring individual incisor tooth widths than the use of wax exemplars. There were fewer differences by investigators using CBCT than others using an F-test in a mixed model of the measurement differences of investigators, wax type, and which tooth was measured. In addition, the frequency of outliers was less in the CBCT method (a total of 5) as compared to the two-dimensional measurements in ether Aluwax (a total of 8) or Coprwax (a total of 12). Both results indicate that CBCT measurements accounted more precisely for tooth width and level of eruption

    Wide-band-gap InAlAs solar cell for an alternative multijunction approach

    Get PDF
    We have fabricated an In_(0.52)Al_(0.48)As solar cell lattice-matched to InP with efficiency higher than 14% and maximum external quantum efficiency equal to 81%. High quality, dislocation-free In_xAl_(1−x)As alloyed layers were used to fabricate the single junction solar cell. Photoluminescence of In_xAl_(1−x)As showed good material quality and lifetime of over 200 ps. A high band gap In_(0.35)Al_(0.65)As window was used to increase light absorption within the p-n absorber layer and improve cell efficiency, despite strain. The InAlAs top cell reported here is a key building block for an InP-based three junction high efficiency solar cell consisting of InAlAs/InGaAsP/InGaAs lattice-matched to the substrate

    Towards an optimized all lattice-matched InAlAs/InGaAsP/InGaAs multijunction solar cell with efficiency >50%

    Get PDF
    An approach for an all lattice-matched multijunction solar cell optimized design is presented with 5.807 Å lattice constant, together with a detailed analysis of its performance by means of full device modeling. The simulations show that a (1.93 eV)In_(0.37)Al_(0.63)As/(1.39 eV)In_(0.38)Ga_(0.62)As_(0.57)P_(0.43)/(0.94 eV)In_(0.38)Ga_(0.62)As 3-junction solar cell can achieve efficiencies >51% under 100-suns illumination (with V_(oc) = 3.34 V). As a key proof of concept, an equivalent 3-junction solar cell lattice-matched to InP was fabricated and tested. The independently connected single junction solar cells were also tested in a spectrum splitting configuration, showing similar performance to a monolithic tandem device, with V_(oc) = 1.8 V

    Large Fluctuations in the Horizon Area and what they can tell us about Entropy and Quantum Gravity

    Get PDF
    We evoke situations where large fluctuations in the entropy are induced, our main example being a spacetime containing a potential black hole whose formation depends on the outcome of a quantum mechanical event. We argue that the teleological character of the event horizon implies that the consequent entropy fluctuations must be taken seriously in any interpretation of the quantal formalism. We then indicate how the entropy can be well defined despite the teleological character of the horizon, and we argue that this is possible only in the context of a spacetime or ``histories'' formulation of quantum gravity, as opposed to a canonical one, concluding that only a spacetime formulation has the potential to compute --- from first principles and in the general case --- the entropy of a black hole. From the entropy fluctuations in a related example, we also derive a condition governing the form taken by the entropy, when it is expressed as a function of the quantal density-operator.Comment: 35 pages, plain Tex, needs mathmacros.tex and msmacros.te

    Screening for brain aneurysm in the Familial Intracranial Aneurysm study: frequency and predictors of lesion detection

    Get PDF
    Object Approximately 20% of patients with an intracranial saccular aneurysm report a family history of intracranial aneurysm (IA) or subarachnoid hemorrhage. A better understanding of predictors of aneurysm detection in familial IA may allow more targeted aneurysm screening strategies. Methods The Familial Intracranial Aneurysm (FIA) study is a multicenter study, in which the primary objective is to define the susceptibility genes related to the formation of IA. First-degree relatives (FDRs) of those affected with IA are offered screening with magnetic resonance (MR) angiography if they were previously unaffected, are ≥ 30 years of age, and have a history of smoking and/or hypertension. Independent predictors of aneurysm detection on MR angiography were determined using the generalized estimating equation version of logistic regression. Results Among the first 303 patients screened with MR angiography, 58 (19.1%) had at least 1 IA, including 24% of women and 11.7% of men. Ten (17.2%) of 58 affected patients had multiple aneurysms. Independent predictors of aneurysm detection included female sex (odds ratio [OR] 2.46, p = 0.001), pack-years of cigarette smoking (OR 3.24 for 20 pack-years of cigarette smoking compared with never having smoked, p < 0.001), and duration of hypertension (OR 1.26 comparing those with 10 years of hypertension to those with no hypertension, p = 0.006). Conclusions In the FIA study, among the affected patients’ FDRs who are > 30 years of age, those who are women or who have a history of smoking or hypertension are at increased risk of suffering an IA and should be strongly considered for screening
    • …
    corecore