9,382 research outputs found

    Evaluation of a posture tracking system

    Get PDF

    Time-dependent response of scoliotic curvature to orthotic intervention: when should a radiograph be obtained after putting on or taking off a spinal orthosis?

    Get PDF
    STUDY DESIGN: A prospective study; 2-group design. OBJECTIVE: This study aims to assess the time response of scoliotic spines to orthotic intervention using clinical ultrasound. SUMMARY OF BACKGROUND DATA: Patients with moderate adolescent idiopathic scoliosis are generally advised orthotic treatment. However, the time to reach maximum correction after donning spinal orthosis or the time to return to pretreatment curvature after doffing spinal orthosis is not fully understood. METHOD: Subjects were divided into 2 groups, the don-orthosis group and the doff-orthosis group where the time reaching maximum correction and the time returning to pretreatment curvature were investigated accordingly. To avoid excessive radiation exposure via obtaining repeated radiographs, a validated method of estimating Cobb angle using radiation-free clinical ultrasound was applied at an interval of every 30 minutes up to 180 minutes. The spinal flexibility (estimated from supine radiographs) and body mass index were collected from the subjects for analyses. RESULT: Nine female patients with adolescent idiopathic scoliosis were recruited. There was no immediate change in the Cobb angles. A change of more than 5° could be observed in both groups only after 30 minutes and maximum change was found at/after 120 minutes. In the doff-orthosis group, the subject with the lowest body mass index took the longest time to increase more than 5° after doffing spinal orthosis. In the don-orthosis group, the subject with the highest body mass index took the longest time to achieve curve correction more than 5°. CONCLUSION: This investigation demonstrated that there is a time lag between application of spinal orthosis and its effect on scoliotic curvature. This is likely due to the low-stiff and viscoelastic properties of the spine. The clinical relevance of this study is that for patients with scoliosis undergoing orthotic treatment, radiograph should not be obtained within 2 hours of putting on or taking off spinal orthosis because it may not show the maximum effect. LEVEL OF EVIDENCE: 4.postprin

    Non-invasive molecular imaging of inflammatory macrophages in allograft rejection.

    Get PDF
    BackgroundMacrophages represent a critical cell type in host defense, development and homeostasis. The ability to image non-invasively pro-inflammatory macrophage infiltrate into a transplanted organ may provide an additional tool for the monitoring of the immune response of the recipient against the donor graft. We therefore decided to image in vivo sialoadhesin (Sn, Siglec 1 or CD169) using anti-Sn mAb (SER-4) directly radiolabelled with (99m)Tc pertechnetate.MethodsWe used a heterotopic heart transplantation model where allogeneic or syngeneic heart grafts were transplanted into the abdomen of recipients. In vivo nanosingle-photon emission computed tomography (SPECT/CT) imaging was performed 7 days post transplantation followed by biodistribution and histology.ResultsIn wild-type mice, the majority of (99m)Tc-SER-4 monoclonal antibody cleared from the blood with a half-life of 167 min and was located predominantly on Sn(+) tissues in the spleen, liver and bone marrow. The biodistribution in the transplantation experiments confirmed data derived from the non-invasive SPECT/CT images, with significantly higher levels of (99m)Tc-SER-4 observed in allogeneic grafts (9.4 (±2.7) %ID/g) compared to syngeneic grafts (4.3 (±10.3) %ID/g) (p = 0.0022) or in mice which received allogeneic grafts injected with (99m)Tc-IgG isotype control (5.9 (±0.6) %ID/g) (p = 0.0185). The transplanted heart to blood ratio was also significantly higher in recipients with allogeneic grafts receiving (99m)Tc-SER-4 as compared to recipients with syngeneic grafts (p = 0.000004) or recipients with allogeneic grafts receiving (99m)Tc-IgG isotype (p = 0.000002).ConclusionsHere, we demonstrate that imaging of Sn(+) macrophages in inflammation may provide an important additional and non-invasive tool for the monitoring of the pathophysiology of cellular immunity in a transplant model

    Pointing-and-Acquisition for Optical Wireless in 6G: From Algorithms to Performance Evaluation

    Get PDF
    The increasing demand for wireless communication services has led to the development of non-terrestrial networks, which enables various air and space applications. Free-space optical (FSO) communication is considered one of the essential technologies capable of connecting terrestrial and non-terrestrial layers. In this article, we analyze considerations and challenges for FSO communications between gateways and aircraft from a pointing-and-acquisition perspective. Based on the analysis, we first develop a baseline method that utilizes conventional devices and mechanisms. Furthermore, we propose an algorithm that combines angle of arrival (AoA) estimation through supplementary radio frequency (RF) links and beam tracking using retroreflectors. Through extensive simulations, we demonstrate that the proposed method offers superior performance in terms of link acquisition and maintenance

    Systematic review recommends the European Organization for Research and Treatment of Cancer colorectal cancer–specific module for measuring quality of life in colorectal cancer patients

    Get PDF
    Objectives: To critically appraise the measurement properties of standardized health-related quality of life (HRQOL) instruments for colorectal cancer (CRC) patients and to provide recommendations on the choice of HRQOL instruments. Study Design and Setting: Systematic review of English language literature published between January 1985 and May 2014 identified through a database search of PubMed, Web of Science, Embase, and Ovid MEDLINE. HRQOL instruments were rated on methodological quality and overall levels of evidence using a Consensus-based Standards for the selection of health Measurement Instrument checklist. Results: Internal consistency and hypothesis testing were evaluated most frequently in 63 studies identified. The Functional Assessment of Cancer Therapy-Colorectal (FACT-C) was the most extensively evaluated. The highest number of positive ratings in the overall level of evidence was found in the CRC-specific quality of life questionnaire module (QLQ-CR38) in European Organization for Research and Treatment of Cancer (EORTC) module, followed by the Memorial Sloan Kettering Cancer Center Bowel instrument, FACT-C, and Quick-FLIC. The EORTC QLQ-CR38 had the most positive ratings on measurement property and was recommended. Conclusion: The EORTC QLQ-CR38 was recommended to assess HRQOL in patients with CRC, regardless of disease stage and primary tumor site.postprin

    Oxygen-Vacancy Engineering of Cerium-Oxide Nanoparticles for Antioxidant Activity

    Full text link
    © 2019 American Chemical Society. To address an important challenge in the engineering of antioxidant nanoparticles, the present work devised a surface-to-bulk migration of oxygen vacancies in the oxygen radical-scavenging cerium-oxide nanoparticles. The study highlights the significance of surface oxygen vacancies in the intended cellular internalization and, subsequently, the radical scavenging activity of the nanoparticles inside the cells. The findings advise future development of therapeutic antioxidant nanomaterials to also include engineering of the particles for enhanced surface defects not only for the accessibility of their oxygen vacancies but also, equally important, rendering them bioavailable for cellular uptake

    High resolution remote sensing of densely urbanised regions : a case study of Hong Kong

    Get PDF
    2008-2009 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe

    Research progress of bone matrix non-collagen protein containing RGD peptides in osteoporosis

    Get PDF
    2008-2009 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
    corecore