47 research outputs found
Reirradiation for Recurrent Meningioma
Purpose/Objective(s): Management options for meningioma include observation, surgical resection, and radiation therapy (RT). In cases of progressive or recurrent disease after RT, similar options exist. The control rate following a second course of RT is unknown.
American Society for Therapeutic Radiation Oncology (ASTRO) 52nd Annual Meeting October 31 - November 4, San Diego, C
Dosimetric validation of a magnetic resonance image gated radiotherapy system using a motion phantom and radiochromic film.
PurposeMagnetic resonance image (MRI) guided radiotherapy enables gating directly on the target position. We present an evaluation of an MRI-guided radiotherapy system's gating performance using an MRI-compatible respiratory motion phantom and radiochromic film. Our evaluation is geared toward validation of our institution's clinical gating protocol which involves planning to a target volume formed by expanding 5 mm about the gross tumor volume (GTV) and gating based on a 3 mm window about the GTV.MethodsThe motion phantom consisted of a target rod containing high-contrast target inserts which moved in the superior-inferior direction inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical planning target volume, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal trajectories and tumor trajectories measured during MRI-guided treatments were used. Similarity of the gated dose distribution to the planned, motion-frozen, distribution was quantified using the gamma technique.ResultsWithout gating, gamma pass rates using 4%/3 mm criteria were 22-59% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% target allowed outside the gating boundary, the gamma pass rate was 97.8% with 3%/3 mm gamma criteria. Using a 3 mm window and 10% allowed excursion, all of the patient tumor motion trajectories at actual speed resulting in at least 95% gamma pass rate at 4%/3 mm.ConclusionsOur results suggest that the device can be used to compensate respiratory motion using a 3 mm gating margin and 10% allowed excursion results in conjunction with repeated breath holds. Full clinical validation requires a comprehensive evaluation of tracking performance in actual patient images, outside the scope of this study
RUBinform
In dieser Ausgabe:
â–ª Schwachstelle Mensch
â–ª E-Mail Spoofing
â–ª Informationssicherheit an der RUB
â–ª Server sicher verorten
â–ª Postkarte oder Einschreiben
RUBinform
In dieser Ausgabe:
▪ Netzwerkdrucker - die unterschätzte Gefahr
â–ª Stromausfall - und jetzt?
â–ª Countdown
â–ª USB Attacken
▪ Informatives für Administratoren
▪ BITS: Urheberrechtsgesetz § 52
RUBinform
In dieser Ausgabe:
â–ª European Cyber Security Month
▪ Das Märchen vom Datacenter
â–ª "Diese Seite verwendet Cookies..."
▪ Interim für die IT
â–ª Die RUB und die DS-GV
RUBinform
In dieser Ausgabe:
▪ Alles Emotet? - Untergründiges
▪ Zeit aufzuräumen
â–ª Die clevere Alternative: Etherpad
â–ª Das neue RUB-Datacenter
â–ª Virus trifft Viru
RUBinform
In dieser Ausgabe:
▪ Gesetz über das Urheberrecht
▪ Neue Regelungen für Bibliotheken
â–ª Rechtliche Aspekte im Forschungsdatenmanagement
â–ª Umgang mit Fotos in Frage gestellt?
▪ Schranken für Forschung, Lehre und Private
RUBinform
In dieser Ausgabe:
â–ª Wie kann ich da sicher sein?
▪ Märchen werden manchmal wahr
â–ª Das smarte Zuhause
â–ª Die clevere Alternative: Sciebo
â–ª Firefox-Addon