238 research outputs found

    Comparison of resource discovery methods

    Get PDF

    New DoBeS web site: Contents & functions

    No full text

    Fiber optic radiation sensing systems for TESLA

    Get PDF

    Simulation studies and background measurements for a laser based beam size monitor for the future linear collider

    Get PDF
    At several locations of the beam delivery system (BDS) of a future linear collider (FLC), beam spot sizes ranging from several hundreds to a few micrometers have to be measured. It is anticipated that laser wires will be used for this task in any FLC design. In order to optimize a laser wire system, simulations and background measurements have been carried out. Results are presented from simulations of the Compton scattering for the PETRA scenario. Furthermore results from measurements of backgrounds like synchrotron radiation and gas scattering have been measured at the positron storage ring PETRA at DESY and will be discussed

    Beam Profile Measurements and Simulations of the PETRA Laser-Wire

    Get PDF
    The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded electrons) downstream of where the laser beam intersects the electron beam. Such a system has been installed at the PETRA storage ring at DESY, which uses a piezo-driven mirror to scan the laser-light across the electron beam. Lat- est results of experimental data taking are presented and compared to detailed simulations using the Geant4 based program BDSIM.Comment: 3 pagesm 4 figures. Submitted as a conference paper for the Particle Accelerator Conference 2005 (PAC05

    Laser Wire Scanner Compton Scattering Techniques for the Measurement of the Transverse Beam Size of Particle Beams at Future Linear Colliders

    Full text link
    This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).Comment: 61 page

    Neurological presentation of Whipple's disease after long-term antibiotic treatment: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Whipple's disease is a rare systemic infectious disorder caused by <it>Tropheryma whipplei</it>.</p> <p>Case presentation</p> <p>We report a 68-year-old male with Whipple's disease of the central nervous system following long-term antibiotic therapy and many years after the initial clinical onset.</p> <p>Conclusion</p> <p>The combination of trimethoprim and sulphamethoxazole does not prevent or cure involvement of the central nervous system in all patients with Whipple's disease. If relapse of the central nervous system occurs treatment with meropenem might be a useful alternative.</p
    • …
    corecore