122 research outputs found

    Comment: Applications of robotics in the clinical laboratory

    Get PDF
    The implementation of a robotic workstation in the clinical laboratory involves considerations and compromises common to any instrument design and development activity. The trade-off between speed and flexibility not only affects the way the instrument interacts with human operators and other devices (the ‘real-world interface’), but also places limitations on the adaptation of chemistries to the given instrument. Mechanical optimization for speed and reproducibility places restrictions on the imprecision of consumables. Attempts to adapt a robot to a constrained system may entail compromises that either degrades the theoretically-attainable quality of results, or requires human interaction to compensate for physical or mechanical limitations. The general considerations of function and workflow, programming and support, and reliability place practical limits on the implementation of robotic workstations in the clinical laboratory

    Use of uteroglobin for the engineering of polyvalent, polyspecific fusion proteins

    Get PDF
    We report a novel strategy to engineer and express stable and soluble human recombinant polyvalent/polyspecific fusion proteins. The procedure is based on the use of a central skeleton of uteroglobin, a small and very soluble covalently linked homodimeric protein that is very resistant to proteolytic enzymes and to pH variations. Using a human recombinant antibody (scFv) specific for the angiogenesis marker domain B of fibronectin, interleukin 2, and an scFv able to neutralize tumor necrosis factor-α, we expressed various biologically active uteroglobin fusion proteins. The results demonstrate the possibility to generate monospecific divalent and tetravalent antibodies, immunocytokines, and dual specificity tetravalent antibodies. Furthermore, compared with similar fusion proteins in which uteroglobin was not used, the use of uteroglobin improved properties of solubility and stability. Indeed, in the reported cases it was possible to vacuum dry and reconstitute the proteins without any aggregation or loss in protein and biological activity

    Synthesis, Characterization, and Molecular Structure of Bis(tetraphenylcyclopentdienyl)rhodium(II)⊗

    Get PDF
    A 5 day diglyme reflux of Rh(acac)3 and K(C5HPh4), followed by treatment with aqueous HPF6, produces orange-yellow [(C5HPh4)2Rh]PF66 in 40 - 50% yield. Reduction of [(C5HPh4)2Rh]PF6 with sodium amalgam in THF yields olive green (C5HPh4)2Rh in 70% yield. (C5HPh4)2Rh crystallizes in the triclinic [Error : unloaded OLE object or mail attachment]space group with unit-cell parameters of a = 8.622 (3) Å, b = 10.778 (4) Å, c = 12.894 (5) Å, a = 65.58 (3)°, b = 72.66 (3)°, g = 83.52 (3)°, and Z = 1. The least squares data refined to RF = 7.63% and RwF = 10.12% for the 2479 independent observed reflections with Fo \u3e 5s(Fo ). The metal-centroid distance is 1.904 Å and all other bond lengths and angles are similar to known octaphenylmetallocenes. ESR spectra of (C5HPh4)2Rh in low-temperature glasses display a rhombic g-tensor with resolution of Rh hyperfine splitting on one-g-component. Analysis of the spectral parameters is consistent with a d7 configuration derived from a nearly degenerate dxz, dyz ground state. Voltammetry and coulometry establish the electron-transfer series (C5HPh4)2Rh1+/0/1- with E° values of -1.44 V and -2.13 V vs ferrocene. The heterogeneous charge transfer rate of the second reduction is about three orders of magnitude lower than that of the first

    Health and performance challenges during sports training and competition in cold weather

    Get PDF
    ABSTRACT Olympic athletes compete and train in diverse coldweather environments, generally without adverse effects. However, the nature of some sports may increase the risk of cold injuries. This paper provides guidance to enable competition organisers and officials, coaches and athletes to avoid cold-weather injuries. This paper will (1) define potential cold-weather injuries during training and competition and (2) provide risk management guidance to mitigate susceptibility to cold-weather injuries

    Synthesis, Characterization, and Crystal Structure of the (η5-C5Ph5)Cr(CO)3 Radical

    Get PDF
    The reaction between Cr(CO)6 and Na(C5Ph5 ) in refluxing diglyme yields [Na(diglyme)3/2][(C5Ph5)Cr(CO)3], 1. Metathesis of 1 with [Ph3P=N=PPh3 ]Cl in CH2Cl2 yields [Ph3P=N=PPh3][(C5Ph5)Cr(CO)3], 2. Oxidation of 1 by AgBF4 in cold THF under an argon atmosphere produces (C5Ph5)Cr(CO)3, 3. Complexes 2 and 3 form a redox pair connected by a quasireversible one-electron process, E0 = -0.69 V vs ferrocene in CH2Cl2, E0 = -0.50 V in CH3CN, ks = 0.12 cm/s. ESR spectra of (C5Ph5)Cr(CO)3 in toluene at 90 K gave a rhombic g-tensor with components 2.1366, 2.0224, and 1.9953, consistent with the expected low-spin d5 electronic configuration. The largest g-tensor component was significantly temperature dependent, suggesting an equilibrium between conformations with 2A´ and 2A˝ ground states. Crystal structures of [Ph3P=N=PPh3][(C5Ph5)Cr(CO)3] and (C5Ph5)Cr(CO)3 were obtained

    RIRS with disposable or reusable scopes : does it make a difference? Results from the multicenter FLEXOR study

    Get PDF
    With several single-use ureteroscopes now available, our aim was to analyze and compare data obtained globally from high-volume centers using both disposable and reusable flexible ureteroscopes and see if indeed in real-world practice either scope has a distinct advantage. Retrospective analysis was performed on the FLEXOR registry, which was created as a TOWER group (Team of Worldwide Endourological Researchers, research wing of the Endourological Society) endeavor. Patients who underwent retrograde intrarenal surgery (RIRS) for renal stones from January 2018 to August 2021 were enrolled from 20 centers globally. A total of 6663 patients whose data were available for analysis were divided into Group 1 (Reusable scopes, 4808 patients) versus Group 2 (Disposable scopes, 1855 patients). The age and gender distribution were similar in both groups. The mean stone size was 11.8 mm and 9.6 mm in Groups 2 and 1, respectively (p 2 cm stones, lower pole stones and of higher Hounsfield unit. Thulium fiber laser (TFL) was used more in Group 2 (p < 0.001). Patients in Group 2 had a slightly higher stone-free rate (SFR) (78.22%) and a lower number of residual fragments (RFs) compared with Group 1 (p < 0.001). The need for further treatments for RF and overall complications was comparable between groups. On multivariate analysis, overall complications were more likely to occur in elderly patients, larger stone size, lower pole stones, and were also more when using disposable scopes with longer operative time. RFs were significantly higher (p < 0.001) for lower pole, larger, harder, multiple stones and in elderly. Our real-world practice observations suggest that urologists choose disposable scopes for bigger, lower pole, and harder stones, and it does indeed help in improving the single-stage SFR if used correctly, with the appropriate lasers and lasing techniques in expert hands

    Prozone effect of serum IgE levels in a case of plasma cell leukemia

    Get PDF
    We describe a case of multiple myeloma (MM) and secondary plasma cell leukemia (PCL) secreting IgE-kappa immunoglobulin. To our knowledge, only 2 cases of IgE-producing secondary PCL have been reported in the medical literature. In our patient, the only tumor marker available for monitoring the therapeutic response to chemotherapy and allogeneic stem cell transplantation was the quantitative M component at serum protein electrophoresis (SPEP), because serum free light chains were in the normal range, Bence-Jones proteinuria was absent, and quantitative serum IgE levels provided inaccurate and erratic results, due to the prozone effect. This is a laboratory phenomenon that occurs when antigen excess interferes with antibody-based methods requiring immune complex formation for detection. It is important to recognize the presence of a prozone effect, because it can produce falsely normal results, and therefore it could lead clinicians to incorrect assessment of the response to therapy

    Consensus statement on concussion in sport—the 5 th international conference on concussion in sport held in Berlin, October 2016

    Get PDF
    The 2017 Concussion in Sport Group (CISG) consensus statement is designed to build on the principles outlined in the previous statements1–4 and to develop further conceptual understanding of sport-related concussion (SRC) using an expert consensus-based approach. This document is developed for physicians and healthcare providers who are involved in athlete care, whether at a recreational, elite or professional level. While agreement exists on the principal messages conveyed by this document, the authors acknowledge that the science of SRC is evolving and therefore individual management and return-to-play decisions remain in the realm of clinical judgement. This consensus document reflects the current state of knowledge and will need to be modified as new knowledge develops. It provides an overview of issues that may be of importance to healthcare providers involved in the management of SRC. This paper should be read in conjunction with the systematic reviews and methodology paper that accompany it. First and foremost, this document is intended to guide clinical practice; however, the authors feel that it can also help form the agenda for future research relevant to SRC by identifying knowledge gaps
    corecore