225 research outputs found
1Design of the Primary Prevention Parameters Evaluation (PREPARE) trial of implantablecardioverter defibrillators to reduce patient morbidity [NCT00279279]
BACKGROUND: Implantable Cardioverter Defibrillator (ICD) therapy has been proven to be beneficial and efficacious for the treatment of serious ventricular tachyarrhythmias in primary prevention patients. However, primary prevention patients appear to have a lower incidence of ventricular arrhythmias in comparison to secondary prevention patients and consequently likely experience a higher proportion of detections due to supraventricular arrhythmias. Recent trials have demonstrated that strategic and specific programming choices reduce the number of inappropriate shocks and that anti-tachycardia pacing (ATP) is an effective alternative to shock therapy for many sustained ventricular arrhythmias. METHODS: The Primary Prevention Parameters Evaluation (PREPARE) study is a multi-center cohort study, evaluating the efficacy of a pre-specified strategic profile of VT/VF detection and therapy settings in 700 primary prevention patients in an effort to safely reduce the number of shock therapies delivered. The patients, both with and without cardiac resynchronization therapy, are compared to a well-qualified set (n = 691) of historical controls derived from the MIRACLE ICD and EMPIRIC trials. This manuscript describes the design of the PREPARE study. The study results, to be presented separately, will characterize the efficacy of this programming set (PREPARE) compared with physician-tailored programming (MIRACLE ICD and EMPIRIC)
Acute left ventricular dysfunction secondary to right ventricular septal pacing in a woman with initial preserved contractility: a case report
<p>Abstract</p> <p>Introduction</p> <p>Right ventricular apical pacing-related heart failure is reported in some patients after long-term pacing. The exact mechanism is not yet clear but may be related to left ventricular dyssynchrony induced by right ventricular apical pacing. Right ventricular septal pacing is thought to deteriorate left ventricular function less frequently because of a more normal left ventricular activation pattern.</p> <p>Case presentation</p> <p>We report the case of a 55-year-old Tunisian woman with preserved ventricular function, implanted with a dual-chamber pacemaker for complete atrioventricular block. Right ventricular septal pacing induced a major ventricular dyssynchrony, severe left ventricular ejection fraction deterioration and symptoms of congestive heart failure. Upgrading to a biventricular device was associated with a decrease in the symptoms and the ventricular dyssynchrony, and an increase of left ventricular ejection fraction.</p> <p>Conclusion</p> <p>Right ventricular septal pacing can induce reversible left ventricular dysfunction and heart failure secondary to left ventricular dyssynchrony. This complication remains an unpredictable complication of right ventricular septal pacing.</p
Mid-term echocardiographic follow up of left ventricular function with permanent right ventricular pacing in pediatric patients with and without structural heart disease
BACKGROUND: Chronic right ventricular apical pacing may have detrimental effect on left ventricular function and may promote to heart failure in adult patients with left ventricular dysfunction. METHODS: A group of 99 pediatric patients with previously implanted pacemaker was studied retrospectively. Forty-three patients (21 males) had isolated congenital complete or advanced atrioventricular block. The remaining 56 patients (34 males) had pacing indication in the presence of structural heart disease. Thirty-two of them (21 males) had isolated structural heart disease and the remaining 24 (13 males) had complex congenital heart disease. Patients were followed up for an average of 53 ± 41.4 months with 12-lead electrocardiogram and transthoracic echocardiography. Left ventricular shortening fraction was used as a marker of ventricular function. QRS duration was assessed using leads V(5 )or II on standard 12-lead electrocardiogram. RESULTS: Left ventricular shortening fraction did not change significantly after pacemaker implantation compared to preimplant values overall and in subgroups. In patients with complex congenital heart malformations shortening fraction decreased significantly during the follow up period. (0.45 ± 0.07 vs 0.35 ± 0.06, p = 0.015). The correlation between the change in left ventricular shortening fraction and the mean increase of paced QRS duration was not significant. Six patients developed dilated cardiomyopathy, which was diagnosed 2 months to 9 years after pacemaker implantation. CONCLUSION: Chronic right ventricular pacing in pediatric patients with or without structural heart disease does not necessarily result in decline of left ventricular function. In patients with complex congenital heart malformations left ventricular shortening fraction shows significant decrease
Initial experience with magnetic resonance imaging-safe pacemakers: A review
Due of its superior soft tissue imaging capabilities, magnetic resonance imaging (MRI) has become the imaging modality of choice in many clinical situations, as illustrated by the tremendous growth in the number of MRIs performed over the past 2 decades. In parallel, the number of patients who require pacemakers or implantable cardiac defibrillators is increasing as indications for these devices broaden and the population ages. Taken together, these phenomena present an important clinical issue, as MR scans are generally contraindicated—except in urgent situations—in patients who have implanted cardiovascular devices. Potentially deleterious interactions between the magnetic fields and radio frequency (RF) energy produced by MR equipment and implantable devices have been identified, including inhibition of pacing, asynchronous/high-rate pacing, lead tip heating, and loss of capture. New devices that incorporate technologies to improve MR safety in patients with pacemakers have recently received approval in Europe and are under evaluation in the United States. Initial data from these devices suggest that these devices are safe in the MRI environment
Microvolt T-wave alternans as a predictor of mortality and severe arrhythmias in patients with left-ventricular dysfunction: a systematic review and meta-analysis
<p>Abstract</p> <p>Background</p> <p>Studies have demonstrated that the use of implantable cardioverter defibrillators (ICDs) is effective for the primary prevention of arrhythmic events but due to imposing costs, there remains a need to identify which patients will derive the greatest benefit. Microvolt T-wave alternans (MTWA) has been proposed to assist in this stratification.</p> <p>Methods</p> <p>We systematically searched the literature using MEDLINE, EMBASE, Current Contents, the Cochrane Library, INAHTA, and the Web of Science to identify all primary prevention randomized controlled trials and prospective cohort studies with at least 12 months of follow-up examining MTWA as a predictor of mortality and severe arrhythmic events in patients with severe left-ventricular dysfunction. The search was limited to full-text English publications between January 1990 and May 2007. The primary outcome was a composite of mortality and severe arrhythmias. Data were synthesized using Bayesian hierarchical models.</p> <p>Results</p> <p>We identified no trials and 8 published cohort studies involving a total of 1,946 patients, including 332 positive, 656 negative, 84 indeterminate, and 874 non-negative (which includes both positive and indeterminate tests) MTWA test results. The risk of mortality or severe arrhythmic events was higher in patients with a positive MTWA compared to a negative test (RR = 2.7, 95% credible interval (CrI) = 1.4, 6.1). Similar results were obtained when comparing non-negative MTWA to a negative test.</p> <p>Conclusion</p> <p>A positive MTWA test predicts mortality or severe arrhythmic events in a population of individuals with severe left ventricular dysfunction. However, the wide credible interval suggests the clinical utility of this test remains incompletely defined, ranging from very modest to substantial. Additional high quality studies are required to better refine the role of MTWA in the decision making process for ICD implantation.</p
Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands: An expert consensus report of the Netherlands Society of Cardiology
Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession
- …