172 research outputs found

    Axillary Surgery in DCIS: Is Less More?

    Full text link

    Quantum dots in axillary lymph node mapping: Biodistribution study in healthy mice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast cancer is the first cause of cancer death among women and its incidence doubled in the last two decades. Several approaches for the treatment of these cancers have been developed. The axillary lymph node dissection (ALND) leads to numerous morbidity complications and is now advantageously replaced by the dissection and the biopsy of the sentinel lymph node. Although this approach has strong advantages, it has its own limitations which are manipulation of radioactive products and possible anaphylactic reactions to the dye. As recently proposed, these limitations could in principle be by-passed if semiconductor nanoparticles (quantum dots or QDs) were used as fluorescent contrast agents for the <it>in vivo </it>imaging of SLN. QDs are fluorescent nanoparticles with unique optical properties like strong resistance to photobleaching, size dependent emission wavelength, large molar extinction coefficient, and good quantum yield.</p> <p>Methods</p> <p>CdSe/ZnS core/shell QDs emitting around 655 nm were used in our studies. 20 μL of 1 μM (20 pmol) QDs solution were injected subcutaneously in the anterior paw of healthy nude mice and the axillary lymph node (ALN) was identified visually after injection of a blue dye. <it>In vivo </it>fluorescence spectroscopy was performed on ALN before the mice were sacrificed at 5, 15, 30, 60 min and 24 h after QDs injection. ALN and all other organs were removed, cryosectioned and observed in fluorescence microscopy. The organs were then chemically made soluble to extract QDs. Plasmatic, urinary and fecal fluorescence levels were measured.</p> <p>Results</p> <p>QDs were detected in ALN as soon as 5 min and up to 24 h after the injection. The maximum amount of QDs in the ALN was detected 60 min after the injection and corresponds to 2.42% of the injected dose. Most of the injected QDs remained at the injection site. No QDs were detected in other tissues, plasma, urine and feces.</p> <p>Conclusion</p> <p>Effective and rapid (few minutes) detection of sentinel lymph node using fluorescent imaging of quantum dots was demonstrated. This work was done using very low doses of injected QDs and the detection was done using a minimally invasive method.</p

    A Longitudinal Comparison of Arm Morbidity in Stage I–II Breast Cancer Patients Treated with Sentinel Lymph Node Biopsy, Sentinel Lymph Node Biopsy Followed by Completion Lymph Node Dissection, or Axillary Lymph Node Dissection

    Get PDF
    Background:\ud Long-term shoulder and arm function following sentinel lymph node biopsy (SLNB) may surpass that following complete axillary lymph node dissection (CLND) or axillary lymph node dissection (ALND). We objectively examined the morbidity and compared outcomes after SLNB, SLNB + CLND, and ALND in stage I/II breast cancer patients.\ud \ud Materials and Methods:\ud Breast cancer patients who had SLNB (n = 51), SLNB + CLND (n = 55), and ALND (n = 65) were physically examined 1 day before surgery (T0), and after 6 (T1), 26 (T2), 52 (T3), and 104 (T4) weeks. Differences in 8 parameters between the affected and unaffected arms were calculated. General linear models were computed to examine time, group, and interaction effects.\ud \ud Results:\ud All outcomes changed significantly, mostly nonlinearly, over time (T0–T4). Between T1 and T4, limitations decreased in abduction (all groups); anteflexion, abduction-exorotation, abduction strength (SLNB + CLND, ALND); flexion strength (SLNB + CLND); and arm volume (SLNB, SLNB + CLND). At T4, limitations in anteflexion (SLNB, ALND), abduction (SLNB + CLND, ALND), exorotation (ALND), abduction-exorotation (all groups), and volume (SLNB + CLND, ALND) increased significantly compared with T0. The SLNB group showed an advantage in anteflexion, abduction, abduction-exorotation, and volume. Groups changed significantly but differently over time in anteflexion, abduction, abduction/exorotation, abduction strength, flexion strength, and volume. Effect sizes varied from 0.19 to 0.00.\ud \ud Conclusion:\ud Initial declines in range of motion and strength were followed by recovery, although not always to presurgery levels. Range of motion and volume outcomes were better for SLNB than ALND, but not strength. SLNB surpassed SLNB + CLND in 2 of the range of motion variables. The clinical relevance of these results is negligible
    corecore