4 research outputs found

    The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities

    No full text
    Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich

    Occurrence of radon 222 Rn in curative waters

    No full text
    Radon jest dobrze udokumentowanym czynnikiem ryzyka indukcji nowotworów. Źródłem obecności radonu 222Rn w wodzie jest jego prekursor w promieniotwórczym szeregu uranowo-radowym izotop radu 226Ra. Celem pracy było określenie poziomu występowania radonu 222Rn w wodach leczniczych w Polsce. Przeprowadzono pomiary ponad 220 próbek wód leczniczych. Radon oznaczano metodą ciekłej scyntylacji cząstek alfa i beta. Zakres zmierzonych stężeń zawierał się od 0,90 do 193,10 Bq/dm3. Średnia arytmetyczna ze wszystkich uzyskanych wyników wyniosła 14,51 Bq/dm3. Wartość średnia stężenia radonu w próbkach pobranych z terenu województw śląskiego i dolnośląskiego była o rząd wielkości wyższa od obserwowanych stężeń w próbkach pobranych z pozostałych obszarów objętych badaniami. Tylko dwie ze zbadanych próbek wód leczniczych, pochodzące z terenu województwa dolnośląskiego tj. woda z ujęcia J-300 z Jedliny Zdrój (116,1 Bq/dm3) oraz woda z ujęcia „Marta” w Szczawnie Zdroju (193,1 Bq/dm3) wykazały aktywność promieniotwórczą powyżej 74 Bq/dm3 i mogą być z tego powodu zaklasyfikowane jako wody radonowe. Wartości te są powyżej zalecanego przez Unię Europejską (Recommendation 2001/928/Euratom) limitu dla wody do picia, wynoszącego 100 Bq/dm3. Dotychczas zarówno w ustawodawstwie krajowym jak i UE nie określono maksymalnego dopuszczalnego stężenia radonu w wodach leczniczych.Radon is one of the best known human carcinogens. Natural radon (222Rn) is formed by decay of uranium (238U), directly of radium (226Ra). The aim of this study was to determine the activity concentration of radon in curative waters in Poland. The measurements were performed using alpha and beta liquid scintillation method. Over 220 water samples from Polish spas have been analyzed. Arithmetic mean of radon concentration for curative waters was found to be 14.51 Bq/m3 within the range between 0.90 Bq/m3 to 193.10 Bq/m3. The average concentrations of radon-222 were ten times higher in water from śląskie and dolnośląskie voivodeship than other voivodeships. In two sampls: water from intake J-300 in Jedlina Zdrój (116.1 Bq/dm3) and intake Marta in Szczawno Zdrój (193.1 Bq/dm3) the level of radon 74 Bq/dm3 has been reached and those samples could be classified as radon water. There are no limits for the radon concentration levels in curative waters. There are only recommendation of the Commission of the European Communities 2001/928/Euratom on the protection of the public against exposure to radon in drinking water supplies (100 Bq/l)

    Natural radioactivity of potassium 40K in curative and natural mineral waters and dose estimation

    No full text
    Wody lecznicze i naturalne wody mineralne często charakteryzują się podwyższoną mineralizacją. Ze wzrostem mineralizacji rosną także stężenia naturalnych izotopów promieniotwórczych stanowiących jedno ze źródeł narażenia ludności na promieniowanie jonizujące. Głównymi celami pracy było: (1) określenie stężenia izotopu potasu 40K w próbkach wody, (2) obliczenie obciążających dawek skutecznych (efektywnych) spowodowanych spożyciem wód zawierających potas 40K,(3) zbadanie korelacji pomiędzy stężeniem potasu 40K a zawartością rozpuszczonych substancji stałych (TDS). Stężenia radioizotopu potasu 40K w badanych próbkach oznaczono metodą spektrometrii gamma. Otrzymane stężenia miały wartości z przedziału od 0,65 do 28,42 Bq/dm3. Pomierzone wartości porównano z wartościami obliczonymi na podstawie analiz składu fizykochemicznego wody, które wyniosły od 0,07 do 22,87 Bq/dm3. Obliczona dawka skuteczna (efektywna) wynikająca ze spożycia wody zawierającej radionuklid potasu 40K o stężeniu 2,26 Bq/dm3 była równa 294 nSv/kurację, zaś dawka spowodowana wchłonięciem drogą inhalacyjną wody zawierającej 40K o stężeniu 1,45 Bq/dm3 osiągnęła wartość 9 nSv/kurację.Natural mineral and curative waters often characterize elevated level of mineral components. If the mineralization grows, the concentration natural radionuclides, which are one population’s exposure sources on ionizing radiation, also grows. The main purposes work were: (1) determine the concentration isotope potassium 40K in samples of water, (2) calculate effective doses caused by intake of water with potassium 40K, (3)- explore correlation between potassium 40K concentration and total dissolved solids (TDS). The concentration radioisotope 40K in analysed samples determined by means of gamma spectrometry. Received concentrations have values from the interval 0.65 to 28.42 Bq/dm3. Measured values compared to values calculated from physico-chemical analyses composition of water, which amounted from 0.07 to 22.87 Bq/dm3. The calculated effective dose resulting from intake water with potassium 40K, concentration 2.26 Bq/dm3 equaled 294 nSv by treatment and caused by inhalation water with concentration 40K 1.45 Bq/dm3 reached value 9 nSv by treatment

    Radon 222Rn in drinking water of West Pomeranian Voivodeship and Kuyavian-Pomeranian Voivodeship, Poland

    No full text
    Radon Rn-222 is a commonly occurring natural radionuclide found in the environment from uranium- -radium radioactive series, which is the decay product of radium Ra-226. The presence of radon carries negative health effects. It is, in fact, classifi ed as a carcinogen, and therefore, it is necessary to continuously monitor its concentration. The aim of this study was to determine the level of radon-222 concentration in water intended for human consumption in the two voivodeships of Poland: West Pomeranian and Kuyavian-Pomeranian. Measurements were performed for more than 60 intakes. The level of radon was measured by using the liquid scintillation counting method. The range of measured radon concentration in the water from the West Pomeranian Voivodeship was from 0.90 to 11.41 Bq/dm3 with an average of 5.01 Bq/dm3, while that from the Kuyavian-Pomeranian Voivodeship was from 1.22 to 24.20 Bq/dm3 with an average of 4.67 Bq/dm3. Only in three water intakes, the concentration of radon-222 exceeded the value of 10 Bq/dm3. The obtained results allowed to conclude that population exposure associated with radon-222 in water is negligible and there is no need to take further action. In the case of three intakes where a higher concentration of radon was found, the potential exposure was low
    corecore