4 research outputs found

    Effectiveness, safety and acceptability of Sino-implant (II) during the first year of use: Results from Kenya and Pakistan

    Get PDF
    Background: Sino-implant (II) is a two-rod subcutaneous contraceptive implant used up to 4 years, containing 150 mg of levonorgestrel. We conducted two observational studies of Sino-implant (II) to evaluate its performance in routine service delivery settings.Methods: We enrolled 1326 women age 18-44 who had Sino-implant (II) inserted at clinics in Pakistan and Kenya. Women were followed-up using either an active or passive follow-up scheme in each study. Study outcomes were: one-year cumulative pregnancy and discontinuation rates; rates of insertion and removal complications; adverse event and side effect rates; reasons for discontinuation; and implant acceptability and satisfaction with clinic services.Results: A total of 754 women returned for at least one follow-up visit. The overall Pearl pregnancy rate was 0.4 per 100 woman-years [95% confidence interval (CI) 0.1, 0.9] resulting from 1 confirmed post-insertion pregnancy in Kenya and 4 in Pakistan. Country-specific Pearl rates were 0.2 (95% CI 0.0, 0.9) in Kenya and 0.6 (95% CI 0.2, 1.6) in Pakistan. The total cumulative 12-month probability of removal was 7.6% (95% CI 6.1, 9.1), with country-specific removal probabilities of 3.7% in Kenya (95% CI 2.1, 5.3) and 10.8% in Pakistan (95% CI 8.5, 13.2). Four serious adverse events occurred in Kenya and none occurred in Pakistan; one SAE (an ectopic pregnancy) was possibly related to Sino-implant (II). Most women in both countries said they would recommend the implant to others.Conclusion: The results from these studies reveal high effectiveness and favorable safety and acceptability during the first year of use of Sino-implant.Implication: The favorable Sino-implant (II) findings from Kenya and Pakistan provide further evidence from disparate regions that Sino-implant (II) is safe, effective and acceptable during routine service delivery

    A randomized crossover study to evaluate local tolerability following subcutaneous administration of a new depot medroxyprogesterone acetate contraceptive formulation

    No full text
    Objectives: This study aimed to evaluate and compare local tolerability of investigational drug TV-46046 and reference drug Depo-subQ Provera 104, both containing medroxyprogesterone acetate (MPA) as an active ingredient. Study design: We conducted a randomized, crossover, single-center study. Twenty-seven healthy women aged 25 to 47 years at low risk of pregnancy received a subcutaneous injection of each of the four study drugs (120 mg/0.3 mL of TV-46046, 60 mg/0.3 mL of diluted TV-46046, 0.3 mL of TV-46046 placebo, and 104 mg/0.65 mL of Depo-subQ 104) in different quadrants of the abdomen. We assessed local tolerability by occurrence of injection site reactions (ISRs), as well as injection site pain and overall safety for at least 9 months postinjections. Results: Of a total of 108 study injections, three injections were partial due to needle blockage. We observed a total of 30 ISRs following 105 full-dose injections, including hypopigmentation (n = 24), bruising (n = 4), and atrophy/dimple (n = 2). Eleven cases of hypopigmentation occurred following 25 full-dose injections of undiluted TV-46046 (44.0%), six following 27 full-dose injections of diluted TV-46046 (22.2%), and seven following 26 full-dose injections of Depo-subQ 104 (26.9%). Hypopigmentations occurred on average 8 months postinjection. Injection pain was minimal and dissipated quickly after all four injections. Conclusions: Subcutaneous administration of MPA in a suspension formulation is associated with the delayed onset of hypopigmentation at the site of injection. Although not statistically significant, the rate of ISRs was over 60% higher for undiluted TV-46046 compared to Depo-subQ 104. This difference bears careful monitoring in future studies of TV-46046. Implications: From a safety standpoint, investigational drug TV-46046 is appropriate for further clinical testing as a 6-month contraceptive injectable. The previously underreported hypopigmentation associated with subcutaneous administration of MPA warrants further investigation and acceptability assessment among users of existing Depo-subQ 104 as well as careful monitoring of local tolerability of TV-46046 in future clinical trials. Trial registration: Registered at clinicaltrials.gov no: NCT0281746

    Assessment of the vaginal residence time of biomarkers of semen exposure.

    No full text
    OBJECTIVE: The primary objective of this pilot study is to determine and compare the residence time in the vagina of biomarkers of semen exposure for up to 15 days post exposure. The biomarkers are prostate-specific antigen (PSA), Y chromosome DNA, the sex determining region of the Y chromosome (SRY) and testis-specific protein Y-encoded 4 (TSPY4). The secondary objectives are to determine if biomarker concentrations differed between intercourse and inoculation groups, to establish whether the sampling frequency post exposure affected biomarker concentrations and decay profile and to determine if biomarker concentrations in vaginal swabs obtained by the participant at home were similar to swabs obtained by the nurse in the clinic. STUDY DESIGN: We randomized healthy women to unprotected intercourse (n=17) versus vaginal inoculation with the male partner’s semen in the clinic (n=16). Women were then further randomized to have vaginal swabs obtained at either 7 or 4 time points after semen exposure, up to 15 days post exposure, either obtained at home by the participant or in the clinic by the research nurse. RESULTS: PSA and SRY were markers of recent semen exposure. TSPY4 was detectable in approximately 50% of participants at 15 days post exposure. Unprotected intercourse resulted in significantly higher concentrations of select biomarkers. Sampling frequency and home versus clinic sampling had no significant effect on biomarker concentrations. CONCLUSIONS: Objective biomarkers of recent or distant semen exposure may have great utility for verifying protocol compliance in a variety of clinical trials
    corecore