545 research outputs found
Recommended from our members
In situ surface acoustic wave field probing in microfluidic structures using optical transmission interferometry
The generation of mechanical driving forces in fluids at the microscale can be efficiently realized using acoustic actuators. For this purpose, bulk or surface acoustic waves (SAWs) are typically excited by an electroacoustic transducer, and the acoustic energy is subsequently coupled to the fluid. The resultant acoustic pressure field in the fluid allows for precise manipulation of immersed objects and also for the agitation of the fluid itself. In general, the fluidic actuation capability is mainly determined by the mechanical displacement amplitude at the interface between the fluid and the acoustically active surface. In the case of SAW-based actuators, the fluid most often is directly attached to the substrate surface along which the surface waves propagate. Hence, the lateral distribution of surface displacement amplitude, i.e., the surface acoustic wave field, at the fluid–substrate interface is of particular interest in order to achieve full control of the fluidic actuation. Here, we present a reliable experimental method for the in situ determination of the SAW field on fluid loaded substrate surfaces based on laser interferometry. The optical accessibility of the fluid–substrate interface is realized via transmission through the anisotropic, piezoelectric substrate material requiring only an additional calibration procedure in order to compensate the parasitic influence of effects based on different indices of refraction as well as on complex acousto-optic effects. Finally, the proposed method is demonstrated to yield reliable results of displacement amplitude on the fluid loaded surface and thus, to provide a valuable insight into acoustofluidic coupling that was not available so far
Recommended from our members
Polarization manipulation of surface acoustic waves by metallization patterns on a piezoelectric substrate
Surface acoustic waves (SAWs) with large normal (vertical) surface displacement at the surface are commonly utilized in microfluidic actuators in order to provide the desired momentum transfer to the fluid. We present an alternative concept using a SAW with comparatively small vertical displacement. Such a SAW passes underneath the microfluidic vessel walls with minimum losses but it needs to be converted inside the vessel into surface vibrations with large vertical displacements. The principal operability of the above idea is illustrated by experimental and numerical studies of the polarization conversion of a leaky SAW on 64° rotated Y-cut of lithium niobate owing to the partial metallization of the substrate surface. In particular, it is found that vertical displacements on the metallized surface can be up to 3.5 times higher as compared to their values on the free surface. Results of computations agree reasonably well with measurements carried out with a laser Doppler vibrometer and allow the clarification of some specific features of this polarization conversion by means of spatial frequency analysis. © 2020 Author(s)
Multisensory integration induces body ownership of a handtool, but not any handtool
Bodily boundaries are computed by integrating multisensory bodily signals and can be experimentally manipulated using bodily illusions. Research on tool use demonstrates that tools alter body representations motorically to account for changes in a user's action repertoire. The present experiment sought to unify perceptual and motoric accounts of tool embodiment using a modified Rubber Hand Illusion (RHI) that also addressed the skill and practice aspects of the tool use literature. In Experiment 1, synchronous multisensory stimulation induced perceptual embodiment of a tool, chopsticks. The embodiment of chopsticks was stronger for more skilled participants, and if the illusion was preceded by tool use. In Experiment 2, the illusion was not elicited with a different type of tool, a teacup, showing that not all objects can be incorporated. This experiment helps to clarify the role of perceptual and motoric embodiment and suggests future avenues for research into tools embodiment using this method
Recommended from our members
The complexity of surface acoustic wave fields used for microfluidic applications
Using surface acoustic waves (SAW) for the agitation and manipulation of fluids and immersed particles or cells in lab-on-a-chip systems has been state of the art for several years. Basic tasks comprise fluid mixing, atomization of liquids as well as sorting and separation (or trapping) of particles and cells, e.g. in so-called acoustic tweezers. Even though the fundamental principles governing SAW excitation and propagation on anisotropic, piezoelectric substrates are well-investigated, the complexity of wave field effects including SAW diffraction, refraction and interference cannot be comprehensively simulated at this point of time with sufficient accuracy. However, the design of microfluidic actuators relies on a profound knowledge of SAW propagation, including superposition of multiple SAWs, to achieve the predestined functionality of the devices. Here, we present extensive experimental results of high-resolution analysis of the lateral distribution of the complex displacement amplitude, i.e. the wave field, alongside with the electrical S-parameters of the generating transducers. These measurements were carried out and are compared in setups utilizing travelling SAW (tSAW) excited by single interdigital transducer (IDT), standing SAW generated between two IDTs (1DsSAW, 1D acoustic tweezers) and between two pairs of IDTs (2DsSAW, 2D acoustic tweezers) with different angular alignment in respect to pure Rayleigh mode propagation directions and other practically relevant orientations. For these basic configurations, typically used to drive SAW-based microfluidics, the influence of common SAW phenomena including beam steering, coupling coefficient dispersion and diffraction on the resultant wave field is investigated. The results show how tailoring of the acoustic conditions, based on profound knowledge of the physical effects, can be achieved to finally realize a desired behavior of a SAW-based microacoustic-fluidic system. © 2020 Elsevier B.V
Tool Embodiment: The Tool’s Output Must Match the User’s Input
The embodiment of tools and rubber hands is believed to involve the modification of two separate body representations: the body schema and the body image, respectively. It is thought that tools extend the capabilities of the body’s action schema, whereas prosthetics like rubber hands are incorporated into the body image itself. Contrary to this dichotomy, recent research demonstrated that chopsticks can be embodied perceptually during a modified version of the rubber hand illusion (RHI) in which tools are held by the rubber hand and by the participant. In the present research, two experiments examined tool morpho-functional (tool output affordance, e.g., precision grasping) and sensorimotor (tool input, e.g., precision grip) match as a mechanism for this tool-use dependent change to the body image. Proprioceptive drift in the RHI occurred when the tool’s output and the user’s input matched, but not when this match was absent. This suggests that this factor may be necessary for tools to interact with the body image in the RHI
Partial purification, characterization and translation in vitro of rat liver metallothionein messenger ribonucleic acid
Recommended from our members
Converse Magnetoelectric Composite Resonator for Sensing Small Magnetic Fields
Magnetoelectric (ME) thin film composites consisting of sputtered piezoelectric (PE) and magnetostrictive (MS) layers enable for measurements of magnetic fields passively, i.e. an AC magnetic field directly generates an ME voltage by mechanical coupling of the MS deformation to the PE phase. In order to achieve high field sensitivities a magnetic bias field is necessary to operate at the maximum piezomagnetic coefficient of the MS phase, harnessing mechanical resonances further enhances this direct ME effect size. Despite being able to detect very small AC field amplitudes, exploiting mechanical resonances directly, implies a limitation to available signal bandwidth along with the inherent inability to detect DC or very low frequency magnetic fields. The presented work demonstrates converse ME modulation of thin film Si cantilever composites of mesoscopic dimensions (25 mm × 2.45 mm × 0.35 mm), employing piezoelectric AlN and magnetostrictive FeCoSiB films of 2 µm thickness each. A high frequency mechanical resonance at about 515 kHz leads to strong induced voltages in a surrounding pickup coil with matched self-resonance, leading to field sensitivities up to 64 kV/T. A DC limit of detection of 210 pT/Hz1/2 as well as about 70 pT/Hz1/2 at 10 Hz, without the need for a magnetic bias field, pave the way towards biomagnetic applications
Evidence and Ideology in Macroeconomics: The Case of Investment Cycles
The paper reports the principal findings of a long term research project on the description and explanation of business cycles. The research strongly confirmed the older view that business cycles have large systematic components that take the form of investment cycles. These quasi-periodic movements can be represented as low order, stochastic, dynamic processes with complex eigenvalues. Specifically, there is a fixed investment cycle of about 8 years and an inventory cycle of about 4 years. Maximum entropy spectral analysis was employed for the description of the cycles and continuous time econometrics for the explanatory models. The central explanatory mechanism is the second order accelerator, which incorporates adjustment costs both in relation to the capital stock and the rate of investment. By means of parametric resonance it was possible to show, both theoretically and empirically how cycles aggregate from the micro to the macro level. The same mathematical tool was also used to explain the international convergence of cycles. I argue that the theory of investment cycles was abandoned for ideological, not for evidential reasons. Methodological issues are also discussed
A multipurpose experimental facility for advanced X-ray Spectrometry applications
Ponencia presentada en la European Conference on X-Ray Spectrometry (EXRS). 2014Motivation, Ultra High Vacuum Chamber (UHVC) project: To support/enhance the training of scientists/engineers from developing countries in the operation of synchrotron radiation instrumentation; To provide beam time access for R&D projects and hands-on training in SR-XRS based techniques; To promote networking and knowledge sharing; To increase the quality and the competitiveness of the developing countries to apply beam time proposals at SR facilities; To contribute in the further development of XRS techniques in applications with socioeconomicalrelevance (characterization of energy storage/conversion materials, environmental, biological and biomedical applications)Fil: Leani, Juan José. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física; Argentina.Fil: Leani, Juan José. Nuclear Science and Instrumentation Laboratory, IAEA Laboratories; Austria.Física Atómica, Molecular y Química (física de átomos y moléculas incluyendo colisión, interacción con radiación, resonancia magnética, Moessbauer Efecto.
Antimicrobial Peptides and Skin: A Paradigm of Translational Medicine
Antimicrobial peptides (AMPs) are small, cationic, amphiphilic peptides with broad-spectrum microbicidal activity against both bacteria and fungi. In mammals, AMPs form the first line of host defense against infections and generally play an important role as effector agents of the innate immune system. The AMP era was born more than 6 decades ago when the first cationic cyclic peptide antibiotics, namely polymyxins and tyrothricin, found their way into clinical use. Due to the good clinical experience in the treatment of, for example, infections of mucus membranes as well as the subsequent understanding of mode of action, AMPs are now considered for treatment of inflammatory skin diseases and for improving healing of infected wounds. Based on the preclinical findings, including pathobiochemistry and molecular medicine, targeted therapy strategies are developed and first results indicate that AMPs influence processes of diseased skin. Importantly, in contrast to other antibiotics, AMPs do not seem to propagate the development of antibiotic-resistant micro-organisms. Therefore, AMPs should be tested in clinical trials for their efficacy and tolerability in inflammatory skin diseases and chronic wounds. Apart from possible fields of application, these peptides appear suited as an example of the paradigm of translational medicine for skin diseases which is today seen as a `two-way road' - from bench to bedside and backwards from bedside to bench. Copyright (c) 2012 S. Karger AG, Base
- …