47 research outputs found

    Neutrophils kill antibody-opsonized cancer cells by trogoptosis

    Get PDF
    Destruction of cancer cells by therapeutic antibodies occurs, at least in part, through antibody-dependent cellular cytotoxicity (ADCC), and this can be mediated by various Fc-receptor-expressing immune cells, including neutrophils. However, the mechanism(s) by which neutrophils kill antibody-opsonized cancer cells has not been established. Here, we demonstrate that neutrophils can exert a mode of destruction of cancer cells, which involves antibody-mediated trogocytosis by neutrophils. Intimately associated with this is an active mechanical disruption of the cancer cell plasma membrane, leading to a lytic (i.e., necrotic) type of cancer cell death. Furthermore, this mode of destruction of antibody-opsonized cancer cells by neutrophils is potentiated by CD47-SIRPa checkpoint blockade. Collectively, these findings show that neutrophil ADCC toward cancer cells occurs by a mechanism of cytotoxicity called trogoptosis, which can be further improved by targeting CD47-SIRPa interactions

    Comparison of two protective lung ventilatory regimes on oxygenation during one-lung ventilation: a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The efficacy of protective ventilation in acute lung injury has validated its use in the operating room for patients undergoing thoracic surgery with one-lung ventilation (OLV). The purpose of this study was to investigate the effects of two different modes of ventilation using low tidal volumes: pressure controlled ventilation (PCV) vs. volume controlled ventilation (VCV) on oxygenation and airway pressures during OLV.</p> <p>Methods</p> <p>We studied 41 patients scheduled for thoracoscopy surgery. After initial two-lung ventilation with VCV patients were randomly assigned to one of two groups. In one group OLV was started with VCV (tidal volume 6 mL/kg, PEEP 5) and after 30 minutes ventilation was switched to PCV (inspiratory pressure to provide a tidal volume of 6 mL/kg, PEEP 5) for the same time period. In the second group, ventilation modes were performed in reverse order. Airway pressures and blood gases were obtained at the end of each ventilatory mode.</p> <p>Results</p> <p>PaO<sub>2</sub>, PaCO<sub>2 </sub>and alveolar-arterial oxygen difference did not differ between PCV and VCV. Peak airway pressure was significantly lower in PCV compared with VCV (19.9 ± 3.8 cmH<sub>2</sub>O vs 23.1 ± 4.3 cmH<sub>2</sub>O; p < 0.001) without any significant differences in mean and plateau pressures.</p> <p>Conclusions</p> <p>In patients with good preoperative pulmonary function undergoing thoracoscopy surgery, the use of a protective lung ventilation strategy with VCV or PCV does not affect the oxygenation. PCV was associated with lower peak airway pressures.</p
    corecore