44 research outputs found

    Case report: Fatal traumatic coronary artery dissection—an overlooked complication of chest fracture

    Get PDF
    Coronary artery dissection caused by trauma is a rare occurrence that can be life-threatening. Accordingly, its rapid identification and treatment are essential to improve patient outcomes. Here, we present a case of a patient who suffered multiple rib and femur fractures after falling from a height of eighteen meters and subsequently experienced persistent chest pain. After the initial diagnostic workup, the medical team diagnosed the patient's chest pain as rib fractures and failed to consider the potential of a cardiac injury as the underlying cause. No emphasis was placed on monitoring changes in myocardial enzymes and ECG, which could have indicated coronary artery dissection. The dissection was confirmed and treated with a stent only after the subsequent coronary angiography (CAG) and optical coherence tomography (OCT) examinations, gradually relieving the patient's chest pain. In this case report, we discuss the management of fractures complicated by traumatic coronary artery dissection and highlight the benefits of OCT in diagnosing and treating this condition. The case also emphasizes the importance of considering coronary artery injury in patients with chest pain due to trauma

    Preoperative diagnosis of solitary pulmonary nodules with a novel hematological index model based on circulating tumor cells

    Get PDF
    ObjectivePreoperative noninvasive diagnosis of the benign or malignant solitary pulmonary nodule (SPN) is still important and difficult for clinical decisions and treatment. This study aimed to assist in the preoperative diagnosis of benign or malignant SPN using blood biomarkers.MethodsA total of 286 patients were recruited for this study. The serum FR+CTC, TK1, TP, TPS, ALB, Pre-ALB, ProGRP, CYFRA21-1, NSE, CA50, CA199, and CA242 were detected and analyzed.ResultsIn the univariate analysis, age, FR+CTC, TK1, CA50, CA19.9, CA242, ProGRP, NSE, CYFRA21-1, and TPS showed the statistical significance of a correlation with malignant SPNs (P <0.05). The highest performing biomarker is FR+CTC (odd ratio [OR], 4.47; 95% CI: 2.57–7.89; P <0.001). The multivariate analysis identified that age (OR, 2.69; 95% CI: 1.34–5.59, P = 0.006), FR+CTC (OR, 6.26; 95% CI: 3.09–13.37, P <0.001), TK1 (OR, 4.82; 95% CI: 2.4–10.27, P <0.001), and NSE (OR, 2.06; 95% CI: 1.07–4.06, P = 0.033) are independent predictors. A prediction model based on age, FR+CTC, TK1, CA50, CA242, ProGRP, NSE, and TPS was developed and presented as a nomogram, with a sensitivity of 71.1% and a specificity of 81.3%, and the AUC was 0.826 (95% CI: 0.768–0.884).ConclusionsThe novel prediction model based on FR+CTC showed much stronger performance than any single biomarker, and it can assist in predicting benign or malignant SPNs

    Exploring the Potential of Integrated Optical Sensing and Communication (IOSAC) Systems with Si Waveguides for Future Networks

    Full text link
    Advanced silicon photonic technologies enable integrated optical sensing and communication (IOSAC) in real time for the emerging application requirements of simultaneous sensing and communication for next-generation networks. Here, we propose and demonstrate the IOSAC system on the silicon nitride (SiN) photonics platform. The IOSAC devices based on microring resonators are capable of monitoring the variation of analytes, transmitting the information to the terminal along with the modulated optical signal in real-time, and replacing bulk optics in high-precision and high-speed applications. By directly integrating SiN ring resonators with optical communication networks, simultaneous sensing and optical communication are demonstrated by an optical signal transmission experimental system using especially filtering amplified spontaneous emission spectra. The refractive index (RI) sensing ring with a sensitivity of 172 nm/RIU, a figure of merit (FOM) of 1220, and a detection limit (DL) of 8.2*10-6 RIU is demonstrated. Simultaneously, the 1.25 Gbps optical on-off-keying (OOK) signal is transmitted at the concentration of different NaCl solutions, which indicates the bit-error-ratio (BER) decreases with the increase in concentration. The novel IOSAC technology shows the potential to realize high-performance simultaneous biosensing and communication in real time and further accelerate the development of IoT and 6G networks.Comment: 11pages, 5 figutre

    Space advanced technology demonstration satellite

    Get PDF
    The Space Advanced Technology demonstration satellite (SATech-01), a mission for low-cost space science and new technology experiments, organized by Chinese Academy of Sciences (CAS), was successfully launched into a Sun-synchronous orbit at an altitude of similar to 500 km on July 27, 2022, from the Jiuquan Satellite Launch Centre. Serving as an experimental platform for space science exploration and the demonstration of advanced common technologies in orbit, SATech-01 is equipped with 16 experimental payloads, including the solar upper transition region imager (SUTRI), the lobster eye imager for astronomy (LEIA), the high energy burst searcher (HEBS), and a High Precision Magnetic Field Measurement System based on a CPT Magnetometer (CPT). It also incorporates an imager with freeform optics, an integrated thermal imaging sensor, and a multi-functional integrated imager, etc. This paper provides an overview of SATech-01, including a technical description of the satellite and its scientific payloads, along with their on-orbit performance

    Application of Contrast-Enhanced Ultrasound (CEUS) in Lymphomatous Lymph Nodes: A Comparison between PET/CT and Contrast-Enhanced CT

    No full text
    Purpose. We described imaging characteristics of different types of lymphomas using contrast-enhanced ultrasound (CEUS) and summarized some simple criteria to distinguish between normal lymph nodes and lymphomatous lymph nodes for clinical diagnosis. Materials and methods. Sixty-one lymphoma patients from 2014 to 2015 with 140 suspicious lymph nodes, who had been confirmed by histology and underwent chemotherapy, were enrolled in our study. The responses to chemotherapy were recorded by PET/CT, contrast-enhanced CT, or CEUS. Results. We summarized the CEUS enhancement patterns as two types when detecting lymphomatous lymph nodes, which could be the specific diagnostic criteria: (1) rapid well-distributed hyperenhancement, with 83.1% lesions exhibiting a fast-in hyperenhancement pattern in the arterial phase, and (2) rapid heterogeneous hyperenhancement, with 16.9% lesions exhibiting heterogeneous in the arterial phase. Particularly, we found that all the suspicious lesions of indolent lymphomas were rapid well-distributed hyperenhancement. CEUS successfully identified 117 lymphomatous lymph nodes, while PET/CT and contrast-enhanced CT detected 124 and 113 lymphomatous lymph nodes, respectively. CEUS had an accuracy of 83.57%, and the accuracy of PET/CT and contrast-enhanced CT was 88.57% and 80.71%, respectively (p=0.188). The false-negative rate was 16.43%, 11.43%, and 19.29%, respectively (p=0.188). Conclusion. CEUS could be a useful tool in detecting lymphomatous nodes. A rapid well-distributed hyperenhancement pattern in CEUS could be a useful diagnostic criterion in both aggressive lymphoma and indolent lymphoma. These results can help us distinguish between lymphomatous and benign lymph nodes and make better diagnostic and therapeutic decisions

    Data_Sheet_1_International curriculum for undergraduate sonographer education in China during the COVID-19 era: International remote teaching mode vs. domestic on-site teaching mode.docx

    No full text
    BackgroundSichuan University West China Medical School was the first institution in China to develop an undergraduate sonographer education program in 2016. This program was certificated by American Registry for Diagnostic Medical Sonography (ARDMS) and students are qualified for the ARDMS credential verification test. In this 4-year program, the international curriculum of ultrasound physics and hemodynamics was set for students in the third year since 2018. This study is aimed to compare the teaching effect of international remote teaching mode and domestic on-site teaching mode of this international curriculum before and during the COVID-19 pandemic.MethodsAll undergraduate sonographer students after completing ultrasound physics and hemodynamics in the academic years 2018–2019 (30 students; before the COVID-19 pandemic) and 2020–2021 (47 students; during the COVID-19 pandemic) were included in the study. The scores of 77 students were analyzed for their curriculum. Independent samples t-test or Mann–Whitney test was employed to compare students' scores before and during the COVID-19 pandemic. The Chi-square test was used to compare students' feedback about this curriculum through an online self-administered questionnaire. A p ResultsTotal scores were comprised of four parts: in-class tests, homework, mid-term, and final exam scores. The mean in-class test score for domestic on-site teaching mode during the COVID-19 pandemic was significantly higher than that for international remote teaching mode before the COVID-19 pandemic. However, there was no observed a statistically significant difference in homework, mid-term, final exam, and total scores between the two types of teaching modes. For questionnaire feedback, no significant difference was observed between the two groups regarding the satisfaction toward teachers, class atmosphere, teaching mode, curriculum content, exam difficulty, scores, and knowledge students gained. For the overall evaluation of the curriculum, 73.3% (22/30) of students were very satisfied before the COVID-19 pandemic, while 44.7% (21/47) of students felt very satisfied during the COVID-19 pandemic (p = 0.02).ConclusionThe general teaching effect of domestic on-site teaching mode during the COVID-19 pandemic was comparable to that of international remote teaching mode before the COVID-19 pandemic, and domestic on-site teaching mode may provide a better in-class teaching effect.</p
    corecore