914 research outputs found

    Using system dynamics in business simulation training games

    Get PDF
    Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1997.Includes bibliographical references (leaves 57-58).by Jennifer Ching-Wen Han.M.Eng

    Hydrothermally Grown ZnO Nanoflowers on a Template-Assisted Ordered Seed Array

    Get PDF
    1-D nanostructure arrays recently attract much attention because of their unique optical, structural, and electronic properties in the field of materials science, microelectronics, and optoelectronic engineering. Zinc Oxide (ZnO) nanoflowers were synthesized by a facile hydrothermal method on a template-assisted deposited ZnO seed array. The ZnO thin film was prepared via a sol-gel spin-coating process on a concave sapphire substrate first. Then an Al layer and an optically clear resin film were individually deposited on the ZnO thin film. After a lift-off process, a convex ZnO seed array film was formed. Finally, ZnO nanoflowers were synthesized by the hydrothermal method at 90oC for 10 to 60 min. The structural, morphological and optical properties of the ZnO nanoflowers were investigated. The XRD results indicate that the ZnO nanoflowers were polycrystalline with a hexagonal wurtzite-type structure with a (002) preferential orientation. The FE-SEM micrographs exhibited the diameter and length of ZnO nanorods increased with the increasing growth time from 10 to 60 min. The 105-nm diameter and 1150-nm length nanorods were obtained with 60-min growth time. Photoluminescence spectra showed a sharp emission peak (IUV) at approximately 380 nm and its intensity increased with the growth time. A weak emission band (IVIS) at 450–550 nm was also observed and the IUV/IVIS increased with the growth time. This result indicates that the defects were reduced and the crystal quality was enhanced with the growth time. The prepared ZnO nanoflowers can be applied to various optoelectronic and sensing devices

    Power Spectral Analyses of Index Finger Skin Blood Perfusion in Carpal Tunnel Syndrome and Diabetic Polyneuropathy

    Get PDF
    The main purpose of this study was to investigate the applicability of frequency domain analysis on laser Doppler flowmetry (LDF) data recorded from the index fingers of patients with carpal tunnel syndrome (CTS) and diabetic polyneuropathy (DPN). Patients with numbness of the palm were recruited and grouped according to the results of electrophysiological examinations into 2×2 groups by the existence or nonexistence of CTS and/or DPN. Skin blood perfusion was recorded by LDF in both the neutral position and the maximally flexed position (the Phalen test). S-transformation was utilized to decompose the recorded data into frequency bands, and the relative band power and power dispersion were calculated. Analysis of variance was used to test the effects of DPN, CTS, and the Phalen test results. The results showed that (1) DPN decreased the absolute power and the relative power in some frequency bands in both positions and CTS increased the power dispersion of some frequency bands only during the Phalen test and (2) there was no difference in the LDF results between patients with positive or negative Phalen test results

    Phosphorylation at Ser473 regulates heterochromatin protein 1 binding and corepressor function of TIF1beta/KAP1

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As an epigenetic regulator, the transcriptional intermediary factor 1β (TIF1β)/KAP1/TRIM28) has been linked to gene expression and chromatin remodeling at specific loci by association with members of the heterochromatin protein 1 (HP1) family and various other chromatin factors. The interaction between TIF1β and HP1 is crucial for heterochromatin formation and maintenance. The HP1-box, PXVXL, of TIF1β is responsible for its interaction with HP1. However, the underlying mechanism of how the interaction is regulated remains poorly understood.</p> <p>Results</p> <p>This work demonstrates that TIF1β is phosphorylated on Ser473, the alteration of which is dynamically associated with cell cycle progression and functionally linked to transcriptional regulation. Phosphorylation of TIF1β/Ser473 coincides with the induction of cell cycle gene <it>cyclin A2 </it>at the S-phase. Interestingly, chromatin immunoprecipitation demonstrated that the promoter of <it>cyclin A2 </it>gene is occupied by TIF1β and that such occupancy is inversely correlated with Ser473 phosphorylation. Additionally, when HP1β was co-expressed with TIF1β/S473A, but not TIF1β/S473E, the colocalization of TIF1β/S473A and HP1β to the promoters of <it>Cdc2 </it>and <it>Cdc25A </it>was enhanced. Non-phosphorylated TIF1β/Ser473 allowed greater TIF1β association with the regulatory regions and the consequent repression of these genes. Consistent with possible inhibition of TIF1β's corepressor function, the phosphorylation of the Ser473 residue, which is located near the HP1-interacting PXVXL motif, compromised the formation of TIF1β-HP1 complex. Finally, we found that the phosphorylation of TIF1β/Ser473 is mediated by the PKCδ pathway and is closely linked to cell proliferation.</p> <p>Conclusion</p> <p>The modulation of HP1β-TIF1β interaction through the phosphorylation/de-phosphorylation of TIF1β/Ser473 may constitute a molecular switch that regulates the expression of particular genes. Higher levels of phosphorylated TIF1β/Ser473 may be associated with the expression of key regulatory genes for cell cycle progression and the proliferation of cells.</p

    Exercise training with negative pressure ventilation improves exercise capacity in patients with severe restrictive lung disease: a prospective controlled study

    Get PDF
    BACKGROUND: Exercise training is of benefit for patients with restrictive lung disease. However, it tends to be intolerable for those with severe disease. We examined whether providing ventilatory assistance by using negative pressure ventilators (NPV) during exercise training is feasible for such patients and the effects of training. METHODS: 36 patients with restrictive lung disease were prospectively enrolled for a 12-week multidisciplinary rehabilitation program. During this program, half of them (n:18; 60.3 ± 11.6 years; 6 men; FVC: 32.5 ± 11.7% predicted ) received regular sessions of exercise training under NPV, whilst the 18 others (59.6 ± 12.3 years; 8 men; FVC: 37.7 ± 10.2% predicted) did not. Exercise capacity, pulmonary function, dyspnea and quality of life were measured. The primary endpoint was the between-group difference in change of 6 minute-walk distance (6MWD) after 12 weeks of rehabilitation. RESULTS: All patients in the NPV-exercise group were able to tolerate and completed the program. The between-group differences were significantly better in the NPV-exercise group in changes of 6MWD (34.1 ± 12.7 m vs. -32.5 ± 17.5 m; P = 0.011) and St George Score (−14.5 ± 3.6 vs. 11.8 ± 6.0; P < 0.01). There was an improvement in dyspnea sensation (Borg’s scale, from 1.4 ± 1.5 point to 0.8 ± 1.3 point, P = 0.049) and a small increase in FVC (from 0.85 ± 0.09 L to 0.91 ± 0.08 L, P = 0.029) in the NPV-exercise group compared to the control group. CONCLUSION: Exercise training with NPV support is feasible for patients with severe restrictive lung diseases, and improves exercise capacity and health-related quality of life

    Broadband Loop Antenna on Soft Contact Lens for Wireless Ocular Physiological Monitoring

    Get PDF
    This paper presents a novel loop antenna with broadband for wireless ocular physiological monitoring (WOPM). The antenna is fabricated on a thin-film poly-para-xylylene C (parylene C) substrate with a small thickness of 11 μm and dimension of π×6.5×6.5 mm2. With the advantage of small size, the proposed antenna is suitable to apply to the soft contact lens and transmit the signal in microelectromechanical Systems (MEMS). Because the pig's eye and human's eye have similar parameters of conductivity and permittivity, the experimental results are obtained by applying the proposed antenna on the pig's eye and cover from 1.54 to 6 GHz for ISM band (2.4 and 5.8 GHz) applications. The measured antenna radiation patterns, antenna gains, and radiation efficiency will be demonstrated in this paper, which are suitable for application of wireless ocular physiological monitoring
    corecore