21 research outputs found

    Erratum: Corrigendum: Sequence and comparative analysis of the chicken genome provide unique perspectives on vertebrate evolution

    Get PDF
    International Chicken Genome Sequencing Consortium. The Original Article was published on 09 December 2004. Nature432, 695–716 (2004). In Table 5 of this Article, the last four values listed in the ‘Copy number’ column were incorrect. These should be: LTR elements, 30,000; DNA transposons, 20,000; simple repeats, 140,000; and satellites, 4,000. These errors do not affect any of the conclusions in our paper. Additional information. The online version of the original article can be found at 10.1038/nature0315

    Safety and performance of the next generation EnligHTN™ renal denervation system in patients with drug-resistant, uncontrolled hypertension: The EnligHTN III first-in-human multicentre study

    Get PDF
    Background/objectives: Catheter-based renal denervation for the treatment of drug-resistant hypertension has been intensively investigated in recent years. To date, only limited data have been published using multi-electrode radiofrequency ablation systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the next generation EnligHTN™ renal denervation system. Six-month primary endpoint data are presented here. Methods: We conducted this first-in-human, prospective, multi-center, non-randomized study in 39 patients (62% male, mean age 63 years, and mean baseline office blood pressure 174/93 mm Hg) with drug-resistant hypertension. The primary safety and efficacy objectives were to characterize, from baseline to 6 months post-procedure, the rate of serious procedural and device related adverse events, as adjudicated by an independent Clinical Events Committee, and the reduction of office systolic blood pressure. Results: Renal artery denervation, using the next generation EnligHTN multi-electrode system significantly reduced office blood pressure from baseline to 1, 3, and 6 months by −19/7, −26/9 and −25/7 mm Hg, respectively (P ≤ 0.0005). No serious device or procedure related adverse events affecting the renal arteries or renal function occurred through. Conclusions: Renal sympathetic denervation using the next generation EnligHTN renal denervation system resulted in safe, rapid, and significant mean office blood pressure reduction that was sustained through 6 months. Future studies will need to address the utility of this system against an appropriate placebo based comparator
    corecore