109 research outputs found
Resistance to Helium Bubble Formation in Amorphous SiOC/Crystalline Fe Nanocomposite
The management of radiation defects and insoluble He atoms represent key challenges for structural materials in existing fission reactors and advanced reactor systems. To examine how crystalline/amorphous interface, together with the amorphous constituents affects radiation tolerance and He management, we studied helium bubble formation in helium ion implanted amorphous silicon oxycarbide (SiOC) and crystalline Fe composites by transmission electron microscopy (TEM). The SiOC/Fe composites were grown via magnetron sputtering with controlled length scale on a surface oxidized Si (100) substrate. These composites were subjected to 50 keV He+ implantation with ion doses chosen to produce a 5 at% peak He concentration. TEM characterization shows no sign of helium bubbles in SiOC layers nor an indication of secondary phase formation after irradiation. Compared to pure Fe films, helium bubble density in Fe layers of SiOC/Fe composite is less and it decreases as the amorphous/crystalline SiOC/Fe interface density increases. Our findings suggest that the crystalline/amorphous interface can help to mitigate helium defect generated during implantation, and therefore enhance the resistance to helium bubble formation
Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton
This paper presents design principles for comfort-centered wearable robots
and their application in a lightweight and backdrivable knee exoskeleton. The
mitigation of discomfort is treated as mechanical design and control issues and
three solutions are proposed in this paper: 1) a new wearable structure
optimizes the strap attachment configuration and suit layout to ameliorate
excessive shear forces of conventional wearable structure design; 2) rolling
knee joint and double-hinge mechanisms reduce the misalignment in the sagittal
and frontal plane, without increasing the mechanical complexity and inertia,
respectively; 3) a low impedance mechanical transmission reduces the reflected
inertia and damping of the actuator to human, thus the exoskeleton is
highly-backdrivable. Kinematic simulations demonstrate that misalignment
between the robot joint and knee joint can be reduced by 74% at maximum knee
flexion. In experiments, the exoskeleton in the unpowered mode exhibits 1.03 Nm
root mean square (RMS) low resistive torque. The torque control experiments
demonstrate 0.31 Nm RMS torque tracking error in three human subjects.Comment: 8 pages, 16figures, Journa
- …