596 research outputs found

    A pan-Asian survey of risk perception, attitudes and practices associated with live animal markets.

    Get PDF
    Key Messages 1. Causal attributions for highly pathogenic avian influenza (HPAI) of the H5N1 virus among live poultry, consumers, retailers and breeders in Vietnam, Thailand, Guangzhou and Hong Kong were studied. 2. Three main themes embodying lay explanation for the causes of H5N1 HPAI emerged: viruses, husbandry-related factors, and vulnerability factors. 3. A deeper understanding of the perceptions of risks, biases, causal attributions, and both the facilitators and barriers to change is needed for planning effective changes in health related behaviour.published_or_final_versio

    Evaluation of 3D printed PCL/PLGA/beta-TCP versus collagen membranes for guided bone regeneration in a beagle implant model

    Get PDF
    Here, we compared 3D-printed polycaprolactone/poly(lactic-co-glycolic acid)/beta-tricalcium phosphate (PCL/PLGA/beta-TCP) membranes with the widely used collagen membranes for guided bone regeneration (GBR) in beagle implant models. For mechanical property comparison in dry and wet conditions and cytocompatibility determination, we analyzed the rate and pattern of cell proliferation of seeded fibroblasts and preosteoblasts using the cell counting kit-8 assay and scanning electron microscopy. Osteogenic differentiation was verified using alizarin red S staining. At 8 weeks following implantation in vivo using beagle dogs, computed tomography and histological analyses were performed after sacrifice. Cell proliferation rates in vitro indicated that early cell attachment was higher in collagen than in PCL/PLGA/beta-TCP membranes; however, the difference subsided by day 7. Similar outcomes were found for osteogenic differentiation, with approximately 2.5 times greater staining in collagen than PCL/PLGA/beta-TCP, but without significant difference by day 14. In vivo, bone regeneration in the defect area, represented by new bone formation and bone-to-implant contact, paralleled those associated with collagen membranes. However, tensile testing revealed that whereas the PCL/PLGA/beta-TCP membrane mechanical properties were conserved in both wet and dry states, the tensile property of collagen was reduced by 99% under wet conditions. Our results demonstrate in vitro and in vivo that PCL/PLGA/beta-TCP membranes have similar levels of biocompatibility and bone regeneration as collagen membranes. In particular, considering that GBR is always applied to a wet environment (e.g. blood, saliva), we demonstrated that PCL/PLGA/beta-TCP membranes maintained their form more reliably than collagen membranes in a wet setting, confirming their appropriateness as a GBR membrane.11109Ysciescopu

    A Novel Role of Three Dimensional Graphene Foam to Prevent Heater Failure during Boiling

    Get PDF
    We report a novel boiling heat transfer (NBHT) in reduced graphene oxide (RGO) suspended in water (RGO colloid) near critical heat flux (CHF), which is traditionally the dangerous limitation of nucleate boiling heat transfer because of heater failure. When the heat flux reaches the maximum value (CHF) in RGO colloid pool boiling, the wall temperature increases gradually and slowly with an almost constant heat flux, contrary to the rapid wall temperature increase found during water pool boiling. The gained time by NBHT would provide the safer margin of the heat transfer and the amazing impact on the thermal system as the first report of graphene application. In addition, the CHF and boiling heat transfer performance also increase. This novel boiling phenomenon can effectively prevent heater failure because of the role played by the self-assembled three-dimensional foam-like graphene network (SFG).open2

    Predicting mental imagery based BCI performance from personality, cognitive profile and neurophysiological patterns

    Get PDF
    Mental-Imagery based Brain-Computer Interfaces (MI-BCIs) allow their users to send commands to a computer using their brain-activity alone (typically measured by ElectroEncephaloGraphy— EEG), which is processed while they perform specific mental tasks. While very promising, MI-BCIs remain barely used outside laboratories because of the difficulty encountered by users to control them. Indeed, although some users obtain good control performances after training, a substantial proportion remains unable to reliably control an MI-BCI. This huge variability in user-performance led the community to look for predictors of MI-BCI control ability. However, these predictors were only explored for motor-imagery based BCIs, and mostly for a single training session per subject. In this study, 18 participants were instructed to learn to control an EEG-based MI-BCI by performing 3 MI-tasks, 2 of which were non-motor tasks, across 6 training sessions, on 6 different days. Relationships between the participants’ BCI control performances and their personality, cognitive profile and neurophysiological markers were explored. While no relevant relationships with neurophysiological markers were found, strong correlations between MI-BCI performances and mental-rotation scores (reflecting spatial abilities) were revealed. Also, a predictive model of MI-BCI performance based on psychometric questionnaire scores was proposed. A leave-one-subject-out cross validation process revealed the stability and reliability of this model: it enabled to predict participants’ performance with a mean error of less than 3 points. This study determined how users’ profiles impact their MI-BCI control ability and thus clears the way for designing novel MI-BCI training protocols, adapted to the profile of each user

    Detection of adeno-associated virus type 2 genome in cervical carcinoma

    Get PDF
    Adeno-associated virus (AAV) can impair the replication of other viruses. Adeno-associated virus seroprevalences have been reported to be lower among women with cervical cancer. In-vitro, AAV can interfere with the production of human papillomavirus virions. Adeno-associated virus-2 DNA has also been detected in cervical cancer tissue, although not consistently. To evaluate the role of AAV infection in relation to invasive cervical cancer, we performed a nested case–control study within a retrospectively followed population-based cohort. A total of 104 women who developed invasive cervical cancer on average 5.6 years of follow-up (range: 0.5 months–26.2 years) and 104 matched control-women who did not develop cervical cancer during the same follow-up time were tested for AAV and human papillomavirus by polymerase chain reaction. At baseline, two (2%) case-women and three (3%) control-women were positive for AAV-2 DNA. At the time of cancer diagnosis, 12 (12%) case-women and 3 (3%) matched control-women were positive for AAV-2 DNA. Persisting AAV infection was not evident. In conclusion, AAV-2 DNA was present in a low proportion of cervical cancers and we found no evidence that the presence of AAV in cervical smears of healthy women would be associated with reduced risk of cervical cancer

    Controlling the shape of a quantum wavefunction

    Full text link
    The ability to control the shape and motion of quantum states(1,2) may lead to methods for bond-selective chemistry and novel quantum technologies, such as quantum computing. The classical coherence of laser light has been used to guide quantum systems into desired target states through interfering pathways(3-5). These experiments used the control of target properties-such as fluorescence from a dye solution(6), the current in a semiconductor(7,8) 8 Or the dissociation fraction of an excited molecule(9)-to infer control over the quantum state. Here we report a direct approach to coherent quantum control that allows us to actively manipulate the shape of an atomic electron's radial wavefunction, We use a computer-controlled laser to excite a coherent state in atomic caesium. The shape of the wavefunction is then measured(10) and the information fed back into the laser control system, which reprograms the optical field. The process is iterated until the measured shape of the wavefunction matches that of a target wavepacket, established at the start of the experiment. We find that, using a variation of quantum holography(11) to reconstruct the measured wavefunction, the quantum state can be reshaped to match the target within two iterations of the feedback loop.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/62625/1/397233a0.pd

    Cumulative survival in early-onset unilateral and bilateral breast cancer: an analysis of 1907 Taiwanese women

    Get PDF
    As the epidemiological pattern of breast cancer in modernising Asian countries differs greatly from that in Western countries, it is worthwhile to investigate the long-term prognoses of unilateral and bilateral breast cancer in these nations. A retrospective cohort study composed of 1907 Taiwanese women was conducted to follow 1863 unilateral and 44 bilateral cases of breast cancer. Time-dependent Cox regression was used to assess the risk of breast cancer death by considering the time course of unilateral and bilateral tumour development. The 15-year survival rates were 68.37, 62.63, and 26.42% for unilateral, synchronous bilateral, and metachronous bilateral breast cancer, respectively. Differences among types were most apparent after 5 years of follow-up. After adjusting for significant prognostic factors, the risk of death for overall bilateral breast cancer was 2.50-fold greater (95% CI, 1.43–4.37) compared to unilateral breast cancer. The corresponding figures were 1.12-fold (95% CI, 0.42–3.02) and 6.11-fold (95% CI, 3.14–11.89) for synchronous and metachronous bilateral breast cancer, respectively. Taiwanese women, who are frequently diagnosed with breast cancer before 50 years of age, showed poorer survival for metachronous bilateral than for synchronous bilateral or unilateral breast cancer. Survival was markedly poorer compared to recent data from Sweden

    Quasi-radial growth of metal tube on si nanowires template

    Get PDF
    It is reported in this article that Si nanowires can be employed as a positive template for the controllable electrochemical deposition of noble metal tube. The deposited tube exhibits good crystallinity. Scanning electron microscope and transmission electron microscope characterizations are conducted to reveal the growth process of metal tube, showing that the metal tube grows quasi-radially on the wall of Si nanowire. The quasi-radial growth of metal enables the fabrication of thickness-defined metal tube via changing deposition time. Inner-diameter-defined metal tube is achieved by choosing Si nanowires with desired diameter as a template. Metal tubes with inner diameters ranging from 1 μm to sub-50 nm are fabricated
    corecore