6,619 research outputs found

    Implantable RF-coiled chip packaging

    Get PDF
    In this paper, we present an embedded chip integration technology that utilizes silicon housings and flexible parylene radio frequency (RF) coils. As a demonstration of this technology, a flexible parylene RF coil has been integrated with an RF identification (RFID) chip. The coil has an inductance of 16 μH, with two layers of metal completely encapsulated in parylene-C. The functionality of the embedded chip is verified using an RFID reader module. Accelerated-lifetime soak testing has been performed in saline, and the results show that the silicon chip is well protected and the lifetime of our parylene-encapsulated RF coil at 37 °C is more than 20 years

    A MEMS electrostatic particle transportation system

    Get PDF
    We demonstrate here an electrostatic MEMS system capable of transporting particles 5-10ÎĽm in diameter in air. This system consists of 3-phase electrode arrays covered by insulators (Figs. 1, 2). Extensive testing of this system has been done using a variety of insulation materials (silicon nitride, photoresist, and Teflon), thickness (0- 12ÎĽm), particle sizes (1-10ÎĽm), particle materials (metal, glass, polystyrene, spores, etc), waveforms, frequencies, and voltages. Although previous literature [1-2] claimed it impractical to electrostatically transport particles with sizes 5-10ÎĽm due to complex surface forces, this effort actually shows it feasible (as high as 90% efficiency) with the optimal combination of insulation thickness, electrode geometry, and insulation material. Moreover, we suggest a qualitative theory for our particle transportation system which is consistent with our data and finite-element electrostatic simulations

    A micro cell lysis device

    Get PDF
    A new micromachined cell lysis device is developed. It is designed for miniature bio-analysis systems where cell lysing is needed to obtain intracellular materials for further analysis such as DNA identification. It consists of muti-electrode pairs to apply electric fields to cells. We adopt the means of using electric field lysing because it can greatly simplify purification steps for preparation of biological samples, when compared to conventional chemical methods. Yeast, Chinese cabbage, radish cells and E. coli are tested with the device. The lysis of yeast, Chinese cabbage, radish cells is observed by a microscope. The experimental observation suggests E. coli are also lysed by the pulsed electric field. The range of electric field for the lysis is on the order of 1 kV/cm to 10 kV/cm. In addition, for practical reasons, we reduce the voltage required for lysing to less than 10 V by making the electrode gap on the order of microns

    Corrosion Behavior of Parylene-Metal-Parylene Thin Films in Saline

    Get PDF
    In this paper, we study the corrosion behavior of parylene-metal-parylene thin films using accelerated-lifetime soak tests. The samples under test are thin film resistors with a 200 nm layer of Au sandwiched by parylene-C on both sides, fabricated with parylene-metal skin technology. The samples are tested in hot saline both passively and actively, and different failure modes are observed using optical and electron-beam metrologies. Bubbles and delamination are first seen in the samples after 2 days of soaking under passive conditions, and followed by metal corrosion. While under active conditions, either bubbles or parylene breakdowns are observed depending on the thickness of parylene packaging. These results contribute to a better understanding of the failure mechanisms of parylene packaging in body fluids

    Electrolysis-based diaphragm actuators

    Get PDF
    This work presents a new electrolysis-based microelectromechanical systems (MEMS) diaphragm actuator. Electrolysis is a technique for converting electrical energy to pneumatic energy. Theoretically electrolysis can achieve a strain of 136 000% and is capable of generating a pressure above 200 MPa. Electrolysis actuators require modest electrical power and produce minimal heat. Due to the large volume expansion obtained via electrolysis, small actuators can create a large force. Up to 100 µm of movement was achieved by a 3 mm diaphragm. The actuator operates at room temperature and has a latching and reversing capability

    Micro Balloon Actuators for Aerodynamic Control

    Get PDF
    A robust, large-force, large-deflection micro balloon actuator for aerodynamic (manoeuvring) control of transonic aircraft has been developed. Using a novel process, high yield linear arrays of silicone balloons on a robust silicon substrate have been fabricated that can deflect vertically in excess of one mm. Balloon actuators have been tested under cyclic conditions to assess reliability. The actuators have been characterized in a wind tunnel to assess their suitability as aerodynamic control surfaces and flight-tested on a jet fighter to assess their resistance to varied temperatures and pressures at high velocity

    Optimal Capacitive Load Matching of Micro Electret Power Generators

    Get PDF
    This paper presents a model of micro-electret power generators. This model uses two capacitors with fixed charge density and variable area to model the actual micro electret power generator. Simulations of power output with capacitive loads and resistive loads are presented. The power output decreases as the load capacitance increases while it increases as the resistive load increases. To verify the model and simulation results, power output generation experiments are performed and the results confirm the simulation. To collect useful energy from the power generator, a small capacitive load, rather than a resistive load, is required

    Aperture excited dielectric antennas

    Get PDF
    The results of a comprehensive experimental and theoretical study of the effect of placing dielectric objects over the aperture of waveguide antennas are presented. Experimental measurements of the radiation patterns, gain, impedance, near-field amplitude, and pattern and impedance coupling between pairs of antennas are given for various Plexiglas shapes, including the sphere and the cube, excited by rectangular, circular, and square waveguide feed apertures. The waveguide excitation of a dielectric sphere is modeled using the Huygens' source, and expressions for the resulting electric fields, directivity, and efficiency are derived. Calculations using this model show good overall agreement with experimental patterns and directivity measurements. The waveguide under an infinite dielectric slab is used as an impedance model. Calculations using this model agree qualitatively with the measured impedance data. It is concluded that dielectric loaded antennas such as the waveguide excited sphere, cube, or sphere-cylinder can produce directivities in excess of that obtained by a uniformly illuminated aperture of the same cross section, particularly for dielectric objects with dimensions of 2 wavelengths or less. It is also shown that for certain configurations coupling between two antennas of this type is less than that for the same antennas without dielectric loading

    Is the Convergence of Accounting Standards Good for Stock Markets?

    Get PDF
    This paper examines the impact of the convergence of Hong Kong Accounting Standard 40 (HKAS 40) with the International Financial Reporting Standard (IFRS) on the stock prices of firms in the property industry. Using a sample of 22111 firm-day observations, we show that the new standard has a negative impact on the stock performance of these firms.Hong Kong Accounting Standard 40, Event Window, Stock Return.

    Bioresorbable Film for the Prevention of Adhesion to the Anterior Spine After Anterolateral Discectomy

    Get PDF
    Background context The development of scar tissue and adhesions postoperatively is a natural consequence of healing but can be associated with medical complications and render reoperation difficult. Many biocompatible products have been evaluated as barriers or deterrents to adhesions. Purpose To evaluate the efficacy of a bioresorbable polylactide film as a barrier to adhesion formation after anterolateral discectomy. Study design Experimental study. Methods Seven, skeletally mature female sheep underwent a retroperitoneal approach to the anterolateral lumbar spine. A discectomy was performed at two levels with an intervening unoperated disc site. One site was treated with a polylactide film barrier (Hydrosorb Shield; MacroPore Biosurgery, San Diego, CA) affixed with tacks manufactured from the same material. The second site was left untreated. Treatment and control sites were randomly assigned. Postmortem analysis included scar tenacity scoring on five spines and histological evaluation on two spines. Results The application of the Hydrosorb film barrier allowed a definite dissection plane during scar tenacity scoring and there was a significant difference in the development of adhesions to the disc between the control and treated sites. Histological evaluation revealed evidence of barrier formation to scar tissue and no significant adverse inflammatory reactions. Conclusions Hydrosorb Shield appears to be an effective postoperative barrier to scar tissue adhesion after anterolateral discectomy. The use of polylactide tacks was beneficial to affix the barrier film in place. Safety issues associated with delayed healing or adverse response to the film or tacks were not observed. Hydrosorb film may be useful as an antiadhesion barrier facilitating dissection during surgical revision in anterior approaches to the spine. Further studies are indicated to evaluate the performance of the bioresorbable material as an antiadhesion barrier in techniques of spinal fusion and disc replacement
    • …
    corecore