59 research outputs found

    Development of a device to simulate tooth mobility

    Get PDF
    Objectives: The testing of new materials under simulation of oral conditions is essential in medicine. For simulation of fracture strength different simulation devices are used for test set-up. The results of these in vitro tests differ because there is no standardization of tooth mobility in simulation devices. The aim of this study is to develop a simulation device that depicts the tooth mobility curve as accurately as possible and creates reproducible and scalable mobility curves. Materials and methods: With the aid of published literature and with the help of dentists, average forms of tooth classes were generated. Based on these tooth data, different abutment tooth shapes and different simulation devices were designed with a CAD system and were generated with a Rapid Prototyping system. Then, for all simulation devices the displacement curves were created with a universal testing machine and compared with the tooth mobility curve. With this new information, an improved adapted simulation device was constructed. Results: A simulations device that is able to simulate the mobility curve of natural teeth with high accuracy and where mobility is reproducible and scalable was developed

    Frequent deletion of the CDKN2A locus in chordoma: analysis of chromosomal imbalances using array comparative genomic hybridisation

    Get PDF
    The initiating somatic genetic events in chordoma development have not yet been identified. Most cytogenetically investigated chordomas have displayed near-diploid or moderately hypodiploid karyotypes, with several numerical and structural rearrangements. However, no consistent structural chromosome aberration has been reported. This is the first array-based study characterising DNA copy number changes in chordoma. Array comparative genomic hybridisation (aCGH) identified copy number alterations in all samples and imbalances affecting 5 or more out of the 21 investigated tumours were seen on all chromosomes. In general, deletions were more common than gains and no high-level amplification was found, supporting previous findings of primarily losses of large chromosomal regions as an important mechanism in chordoma development. Although small imbalances were commonly found, the vast majority of these were detected in single cases; no small deletion affecting all tumours could be discerned. However, the CDKN2A and CDKN2B loci in 9p21 were homo- or heterozygously lost in 70% of the tumours, a finding corroborated by fluorescence in situ hybridisation, suggesting that inactivation of these genes constitute an important step in chordoma development

    Misfolded SOD1 Associated with Motor Neuron Mitochondria Alters Mitochondrial Shape and Distribution Prior to Clinical Onset

    Get PDF
    Mutations in superoxide dismutase (SOD1) are causative for inherited amyotrophic lateral sclerosis. A proportion of SOD1 mutant protein is misfolded onto the cytoplasmic face of mitochondria in one or more spinal cord cell types. By construction of mice in which mitochondrially targeted enhanced green fluorescent protein is selectively expressed in motor neurons, we demonstrate that axonal mitochondria of motor neurons are primary in vivo targets for misfolded SOD1. Mutant SOD1 alters axonal mitochondrial morphology and distribution, with dismutase active SOD1 causing mitochondrial clustering at the proximal side of Schmidt-Lanterman incisures within motor axons and dismutase inactive SOD1 producing aberrantly elongated axonal mitochondria beginning pre-symptomatically and increasing in severity as disease progresses. Somal mitochondria are altered by mutant SOD1, with loss of the characteristic cylindrical, networked morphology and its replacement by a less elongated, more spherical shape. These data indicate that mutant SOD1 binding to mitochondria disrupts normal mitochondrial distribution and size homeostasis as early pathogenic features of SOD1 mutant-mediated ALS

    All-ceramic fixed partial dentures designed according to the DC-Zirkon (R) technique. A 2-year clinical study

    No full text
    The aim of the study was to investigate whether the properties of a pre-sintered, hot iso-static post-compacted ( HIP) ZrO2 are adequate for use in three-five-unit fixed partial dentures (FPDs) and to evaluate the clinical results. Twenty three five-unit FPDs were fabricated for 18 patients on a total of 56 abutments. They were all made on abutments cut with a shoulder preparation and cemented with a zinc phosphate cement. They were clinically followed for 24 months. After 24 months all FPDs were still in use without any fractures or clinical wear but in three cases (15%) minor chip-of fractures were observed. Marginal integrity was rated excellent at 45 abutments and acceptable at 11. Within the limitations of this 2-year clinical follow-up study, FPDs made of pre-sintered HIP ZrO2 core material veneered with a compatible ceramic is an acceptable alternative in the fabrication of FPDs with the extensions investigated in this study. Special attention, however, must be paid to designing the core for an occlusal shape that provides sufficient support for the veneer

    All-ceramic Fixed Partial Dentures Designed According to the DC-Zirkon Technique. A 2-year Clinical Study

    No full text
    The aim of the present in-vitro study was to compare the fracture strength of all-ceramic Fixed Partial Dentures supported by tooth-analogues and periodontal membrane with the same supported by dental implants. As ceramics are highly brittle, they cannot withstand deformations of more than 0.1% without fracturing. Hence, when planning an all-ceramic FPD, it is essential to evaluate abutment sup-port, as the fracture strength of all-ceramic constructions depends on the stability of the support to reduce strain in the beam of the prosthe-sis. The support provided by implants differs, however, from the sup-port provided by natural teeth as the implants are anchored directly in the bone with no intermediate tissue. One question that arises is whether strain and stress in the prosthesis are lower when the prosthe-sis is loaded on implants compared to natural teeth and hence if all-ceramic FPDs benefit from implant support. Twenty-four three-unit all-ceramic FPDs-12 supported by two dental implants and 12 by two tooth-analogues serving as end abutments-were made. All FPDs were subjected to preloading in a preloading procedure and subsequently subjected to load until fracture occurred. Load at fracture were regis-tered and comparisons between the two groups were made. The loads at fracture were statistically significant higher in the group supported by implants compared to the group supported by tooth-analogues (p = 0.003). Within the limitations of this in-vitro study, the following con-clusions can be drawn: All-ceramic fixed partial dentures can be used in combination with dental implants. The solid support gained from implants might thus be beneficial for the outcome of such treatment due to decreased strain and stress levels in the prosthesis when loaded on implants compared to when loaded on natural teeth. Clinical stud-ies are, however, needed to confirm these findings as there are more factors that influence the final clinical outcome

    Influence of firing conditions and production methods on fracture strength of titanium-based metal ceramic crowns

    No full text
    Objectives: This study evaluated the effect of argon atmosphere compared with vacuum during porcelain firing on the fracture strength of crowns made of porcelain and electron beam melted (EBM) Ti-6Al-4 V, cast commercially pure titanium or milled commercially pure titanium. Methods: Sixty crown copings of c. p. titanium, Ti-6Al-4 V alloy and porcelain were fabricated using three production techniques. The copings were fired either under vacuum or in an argon gas atmosphere. Specimens were subdivided into groups of cast c. p. titanium, milled c. p. titanium and EBM Ti-6Al-4 V which were further subdivided according to firing modes employing either vacuum or argon gas. The 60 specimens were subjected to cyclic preloading and thermocycling, and were then individually loaded until interface fractured. Differences between the group mean values were calculated using the one-way ANOVA and Tukey\u27s range test. Two fractured samples from each group were cut with a diamond blade and examined using SEM and EDS for visualization and chemical composition analysis of the fractured interface. Results: The highest mean fracture strength values, though not significant, were recorded for the groups fired in argon atmosphere, and the lowest mean fracture strength values were recorded for the groups fired in vacuum, with one exception. Comparing the two main groups of firing atmosphere, no significant difference could be documented. SEM and EDS analysis indicated clear differences in composition and structure between the groups included in the study. Conclusions: Firing in argon atmosphere does not significantly improve the fracture strength of porcelain bonded to titanium

    Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns

    No full text
    Fahad Bakitian,1,2 Przemek Seweryniak,3 Evaggelia Papia,1 Christel Larsson,1 Per Vult von Steyern1 1Department of Materials Science and Technology, Faculty of Odontology, Malmö University, Malmö, Sweden; 2Department of Restorative Dentistry, Faculty of Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia; 3Commercial Dental Laboratory, Malmö, Sweden Purpose: The aim of this study was to describe different designs of semimonolithic crowns made of translucent and high-translucent zirconia materials and to evaluate the effect on fracture resistance and fracture mode.Methods: One hundred crowns with different designs were produced and divided into five groups (n=20): monolithic (M), partially veneered monolithic (semimonolithic) with 0.3 mm buccal veneer (SM0.3), semimonolithic with 0.5 mm buccal veneer (SM0.5), semimonolithic with 0.5 mm buccal veneer supported by wave design (SMW), and semimonolithic with 0.5 mm buccal veneer supported by occlusal cap design (SMC). Each group was divided into two subgroups (n=10) according to the materials used, translucent and high-translucent zirconia. All crowns underwent artificial aging before loading until fracture. Fracture mode analysis was performed. Fracture loads and fracture modes were analyzed using two-way ANOVA and Fisher’s exact probability tests (P≤0.05).Results: SM0.3 design showed highest fracture loads with no significant difference compared to M and SMW designs (P>0.05). SM0.5 design showed lower fracture loads compared to SMW and SWC designs. Crowns made of translucent zirconia showed higher fracture loads compared to those made of high-translucent zirconia. M, SM0.3, and all but one of the SMC crowns showed complete fractures with significant differences in fracture mode compared to SMW and SM0.5 crowns with cohesive veneer fractures (P≤0.05).Conclusion: Translucent and high-translucent zirconia crowns might be used in combination with 0.3 mm microcoating porcelain layer with semimonolithic design to enhance the esthetic properties of restorations without significantly decreasing fracture resistance of the crowns. If 0.5 mm porcelain layer is needed for a semimonolithic crown, wave design or cap design might be used to increase fracture resistance. In both cases, fracture resistance gained is likely to be clinically sufficient as the registered fracture loads were high in relation to expected loads under clinical use. Keywords: monolithic zirconia, porcelain veneer, Y-TZ
    • …
    corecore