74 research outputs found

    Development of an algorithm for peak detection in comprehensive two-dimensional chromatography

    No full text
    A method for peak detection in two-dimensional chromatography is presented. The algorithm applies first the methods developed for peak detection in one-dimensional chromatography to detect peaks in one dimension. In a second step, a decision tree is applied to decide which one-dimensional peaks are originated from the same compound and have to be 'merged' into one two-dimensional peak. To this end, different features of the peaks (second-dimension peak regions and second-dimension retention times) are compared and different criteria (common peak regions, retention time differences, unimodality in the first dimension) are applied. Different options can be used, depending on the nature of the data. The user controls this decision tree by establishing several options and "switches". The algorithm was tested with GC x GC chromatograms obtained for a commercial air-freshener sample, detecting and merging the modulated peaks belonging to the same compound. Recommendations for the set of options and switches are given. A utility that calculates and sums peak areas from merged peaks is added to facilitate automated quantification. Although the algorithm was developed for GC x GC, its application to comprehensive two-dimensional liquid chromatography (LC x LC) data should at most require minor modifications

    Effect of initial estimates and constraints selection in multivariate curve resolution-Alternating least squares. Application to low-resolution NMR data

    No full text
    A comprehensive study of the applicability of multivariate curve resolution (MCR) methods to series of T2-relaxation filtered 1H NMR spectra of a cross-linked polymer network is presented. A collection of Hahn-echo NMR spectra is obtained at different echo times, yielding two-way data. In this study the applicability of two different types of orthogonal-projection approach (OPA1 and OPA2) (column-wise and row-wise) were tested. Four different strategies of alternating least squares methods were also examined (ALS1, ALS2, ALS3 and ALS4). These strategies differed on the order of measurement for which the constraints were applied in the final output, and the way in which SSR was calculated to monitor for convergence. In the spectral order of measurement, a non-negativity constraint was imposed, whereas in the time order of measurement, the signal was forced to follow an exponential decay. This yielded up to eight MCR configurations, giving different results. For solid-state NMR, the dissimilarity in NMR profiles is significantly lower than the dissimilarity in signal decays, and therefore OPA2 performed better. A final output with a constrained solution in relaxation time was preferred (instead of a constrained solution in NMR spectra) for practical purposes. Differences between the solutions given from the two ALS configurations can be interpreted as a sign of lack of fit.status: publishe
    • …
    corecore