52 research outputs found

    Morphology and function of preserved microvascular arterial grafts: an experimental study in rats

    Get PDF
    The aim of this study is to examine the morphology and function and small-caliber, arterial grafts after preservation in the University of Wisconsin solution (UW). Rat carotid arteries were stored in UW (n = 10) or in phosphate-buffered saline (PBS) (n = 10) for 1, 3, 7, and 14 days and were examined with light microscopy (LM) and scanning electron microscopy (SEM). Rat aortic preparations were stored in UW or PBS for 1 hour, 24 hours, 72 hours, 7 days, and 14 days and assessed for functional responses (stimulated contraction and endothelium-dependent relaxation). Segments (5 mm) of rat carotid arteries were stored in UW or PBS for 3 days, 7 days, and 14 days and orthotopically implanted as autografts and allografts. No immunosuppressive or anticoagulant agents were used. After 28 days of implantation, the grafts were assessed for patency and excised for LM and SEM. In UW, the endothelial layer remained intact up to 9 days of storage. In PBS, the endothelial layer showed deterioration after 1 day and was completely lost after 3 days. Functional responses were demonstrated to exist for as long as 7 days storage in UW. In PBS, no responses could be evoked after 24 hours storage. Autografts preserved in UW for 3 days (n = 6), 7 days (n = 6), and 14 days (n = 6) showed patency rates of 83.3%, 66.6%, and 66.6%, respectively, whereas patency rates of allografts were 66.6%, 33.3%, and 33.3%, respectively. Autografts stored in PBS for 3 days (n = 6), 7 days (n = 6), and 14 days (n = 6) showed patency rates of 33.3%, 33.3%, and 50%, respectively, whereas patency rates of allografts were 16.7%, 0%, and 33.3%, respectively. The UW preserved autografts showed normal morphology. All other groups showed vessel wall degeneration which in the allograft groups, were accompanied by lymphocellular infiltration. In conclusion, the endothelial layer and vessel wall of arteries are adequately preserved in UW. Functional responses are retained up to 14 days storage in UW, but, are lost after 24 hours storage in PBS. Autograft implantation studies accordingly show good performance of arterial segments preserved in UW, whereas allografts are subject to degradation as a result of rejectio

    The antidepressant effect and safety of non-intranasal esketamine:A systematic review

    Get PDF
    BACKGROUND: The introduction of esketamine into the field of psychiatry comes on the heels of excitement from studies on racemic ketamine. While the intranasal route has been the most studied to date, other modes of administration of esketamine may also be of interest in the management of depression. AIMS: To systematically review the literature on non-intranasal esketamine for depression in terms of its antidepressant effect and safety. METHODS: We searched PubMed, Embase, the Cochrane Library, and Google Scholar from inception up to February 2021. Search terms included a combination of Medical Subject Headings and text words indicative of esketamine and depression. We selected both controlled and uncontrolled studies examining non-intranasal esketamine for the treatment of depression. RESULTS: We identified four randomized controlled trials (RCTs) on intravenous esketamine and 15 open-label studies on intravenous (n = 80), subcutaneous (n = 73), and oral (n = 5) esketamine. We found intravenous, subcutaneous, and possibly oral administration of esketamine to be effective in reducing depressive symptoms in most patients with major depressive disorder, bipolar depression, and (severe) treatment-resistant depression. Clinical response to repeated administration of esketamine persisted over the course of treatment. Esketamine was well tolerated by most patients, but open-label data indicate marked psychotomimetic symptoms in exceptional cases. The overall quality of the controlled studies was considered high, the overall quality of the uncontrolled studies low to moderate. CONCLUSIONS: Intravenous, subcutaneous, and possibly oral esketamine may offer an effective and safe addition to the depression treatment armamentarium. However, as most included studies lacked a control group and had small sample sizes, the quality of our results is limited. Different types and formulations of ketamine remain to be compared directly

    Morphology and function of dog arterial grafts preserved in UW-solution

    Get PDF
    Objectives:To assess the function of arterial grafts after prolonged preservation in the University of Wisconsin solution (UW), in vitro and in vivo.Methods:Carotid arteries were harvested from dogs and stored for 1–21 days at 4°C in UW (n = 10) or in PBS (0.9% NaCl, pH 7.4), (PBS) (n = 10). Slices were examined by lightmicroscopy (LM) and scanning electron microscopy (SEM). For viability testing, specimens were connected to an isometric force transducer (2 × n = 9). Contractile and relaxation responses were examined by adding phenylephrine (200μM) and metacholine (200μM), respectively. For in vivo studies (n = 41), 2.5cm carotid artery segments were implanted orthotopically, as autografts and allografts, after 14 days of storage in UW or in PBS. Autologous veins were used as controls. After 28 days or 56 days, arteriography was performed and the grafts were excised for LM and SEM.Results:The arterial endothelial layer remained intact after up to 14 days of storage in UW. In PBS, the endothelium was lost after 3 days. The functional response after 14 days storage in UW was approximately 50% vs. 0% after 14 days in PBS. In the autografts, total patencies (28 days + 56 days) were 100% (8/8) and 63% (5/8) for UW and PBS stored grafts, respectively. In the allografts, the UW and PBS preserved grafts showed total patencies of 86% (12/14) and 83% (5/6), respectively. Microscopically, the allografts showed fibrotic degeneration.Conclusions:Arteries are well preserved in UW up to 14 days of storage. Arterial autografts preserved in UW showed good patency and better integrity of the vessel wall after implantation, than grafts stored in PBS or allografts (without immunosuppressive therapy)

    Mixed Ionic-Electronic Conduction in HTcS

    Full text link

    Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty

    Get PDF
    Objective:This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery.Materials:Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 39 patients before and after PTA were analysed.Results:Angiographically the diameter of the remaining stenosis seen after PTA was classified as < 50% in 31 patients (success); in eight patients a failure was encountered. Evaluating at 6 months the functional and anatomic results of the PTA in 31 patients, the intervention was a success in 14 patients (Group I) and a failure in 17 patients (Group II). The remaining eight patients defined as angiographic failure following PTA comprised Group III. Neither qualitative nor quantitative IVUS data obtained before PTA could predict outcome. Conversely, after PTA, the extent of dissection was significantly more severe in Groups II and III than in Group I. Similarly, significant differences were found between Groups I and II for mean free lumen area (13.2 vs. 9.7 mm2, respectively) and mean free lumen diameter (4.1 vs. 3.5 mm, respectively). Quantitative data obtained in Group II were similar to those in Group III.Conclusion:This preliminary study demonstrates that following PTA the extent of dissection, free lumen area and diameter seen with IVUS are predictive factors of patency. Future studies with more patients are mandatory to further highlight the sensitivity of these observations
    • …
    corecore