19 research outputs found

    Multi parametric Cardiac Magnetic Resonance imaging and arrhythmic risk stratification in Fabry disease

    Get PDF
    Fabry disease is an X-linked lysosomal storage disorder, with cardiovascular manifestations including progressive LVH, chronic myocardial inflammation, fibrosis, congestive cardiac failure, arrhythmia and sudden death. Despite widely available Fabry specific therapies, cardiac involvement has a significant prognostic impact and is still the leading cause of morbidity and mortality in FD. Thus early identification of cardiovascular involvement is key to enable initiation of therapy at the earliest opportunity and prevent progressive cardiomyopathy. The main aims of this thesis are: 1) To characterise the stages of cardiovascular disease and potential mechanisms for arrhythmia in FD; 2) To quantify the burden of arrhythmia and consequent therapy usage in FD e.g. cardiac device implantation. This thesis has provided a significant insight into Fabry cardiomyopathy. The use of CMR tissue characterisation, feature tracking techniques and advanced ECG analysis has shown great promise not only in the detection of early cardiac involvement, but also in potentially predicting adverse clinical outcomes. Risk stratification and early therapy is crucial in reducing morbidity and mortality in Fabry disease and this thesis has provided a platform to provide this information and gain a better understanding of the complex pathophysiology in this rare disease

    Systematic review of the incidence and clinical risk predictors of atrial fibrillation and permanent pacemaker implantation for bradycardia in Fabry disease

    Get PDF
    Introduction Fabry disease (FD) is an X-linked lysosomal storage disorder caused by enzyme deficiency, leading to glycosphingolipid accumulation. Cardiac accumulation triggers local tissue injury, electrical instability and arrhythmia. Bradyarrhythmia and atrial fibrillation (AF) incidence are reported in up to 16% and 13%, respectively.Objective We conducted a systematic review evaluating AF burden and bradycardia requiring permanent pacemaker (PPM) implantation and report any predictive risk factors identified.Methods We conducted a literature search on studies in adults with FD published from inception to July 2019. Study outcomes included AF or bradycardia requiring therapy. Databases included Embase, Medline, PubMed, Web of Science, CINAHL and Cochrane. The Risk of Bias Agreement tool for Non-Randomised Studies (RoBANS) was utilised to assess bias across key areas.Results 11 studies were included, eight providing data on AF incidence or PPM implantation. Weighted estimate of event rates for AF were 12.2% and 10% for PPM. Age was associated with AF (OR 1.05–1.20 per 1-year increase in age) and a risk factor for PPM implantation (composite OR 1.03). Left ventricular hypertrophy (LVH) was associated with AF and PPM implantation.Conclusion Evidence supporting AF and bradycardia requiring pacemaker implantation is limited to single-centre studies. Incidence is variable and choice of diagnostic modality plays a role in detection rate. Predictors for AF (age, LVH and atrial dilatation) and PPM (age, LVH and PR/QRS interval) were identified but strength of association was low. Incidence of AF and PPM implantation in FD are variably reported with arrhythmia burden likely much higher than previously thought.PROSPERO database CRD42019132045

    Clinical utilisation of implantable loop recorders in adults with Fabry disease-a multi-centre snapshot study

    Get PDF
    Fabry disease (FD) is an X-linked deficiency of alpha-galactosidase-A, leading to lysosomal storage of sphingolipids in multiple organs. Myocardial accumulation contributes to arrhythmia and sudden death, the most common cause of FD mortality. Therefore, there is a need for risk stratification and prediction to target device therapy. Implantable loop recorders (ILRs) allow for continual rhythm monitoring for up to 3 years. Here, we performed a retrospective study to evaluate current ILR utilisation in FD and quantify the burden of arrhythmia that was detected, which resulted in a modification of therapy. This was a snapshot assessment of 915 patients with FD across three specialist centres in England during the period between 1 January 2000 and 1 September 2022. In total, 22 (2.4%) patients underwent clinically indicated ILR implantation. The mean implantation age was 50 years and 13 (59%) patients were female. Following implantation, nine (41%) patients underwent arrhythmia detection, requiring intervention (six on ILR and three post-ILR battery depletion). Three patients experienced sustained atrial high-rate episodes and were started on anticoagulation. Three had non-sustained tachyarrhythmia and were started on beta blockers. Post-ILR battery depletion, one suffered complete heart block and two had sustained ventricular tachycardia, all requiring device therapy. Those with arrhythmia had a shorter PR interval on electrocardiography. This study demonstrates that ILR implantation in FD uncovers a high burden of arrhythmia. ILRs are likely to be underutilised in this pro-arrhythmic cohort, perhaps restricted to those with advanced FD cardiomyopathy. Following battery depletion in three patients as mentioned above, greater vigilance and arrhythmia surveillance are advised for those experiencing major arrhythmic events post-ILR monitoring. Further work is required to establish who would benefit most from implantation.</p

    A randomised controlled trial evaluating arrhythmia burden, risk of sudden cardiac death and stroke in patients with Fabry disease:The role of implantable loop recorders (RaILRoAD) compared with current standard practice

    Get PDF
    Background: Fabry disease (FD) is a genetic disorder caused by a deficiency in the enzyme alpha-galactosidase A, leading to an accumulation of glycosphingolipids in tissues across the body. Cardiac disease is the leading cause of morbidity and mortality. Advanced disease, characterised by extensive left ventricular hypertrophy, ventricular dysfunction and fibrosis, is known to be associated with an increase in arrhythmia. Data identifying risk factors for arrhythmia are limited, and no Fabry-specific risk stratification tool is available to select those who may benefit from initiation of medical or device therapy (implantable cardiac defibrillators). Current monitoring strategies have a limited diagnostic yield, and implantable loop recorders (ILRs) have the potential to change treatment and clinical outcomes. Aim: The aim of this study is to determine whether ILRs can (1) improve arrhythmia detection in FD and (2) identify risk predictors of arrhythmia. Methods: A prospective, 5-year, open-label, international, multi-centre randomised controlled trial of a minimum of 164 participants with genetically or enzymatically confirmed FD (or both) who have evidence of cardiac disease will be recruited from five centres: Queen Elizabeth Hospital, Birmingham, UK; Salford Royal Hospital, Salford, UK; Royal Free Hospital, London, UK; Addenbrookes Hospital, Cambridge, UK; and Westmead Hospital, Sydney, Australia. Participants will be block-randomised (1:1) to two study arms for cardiac monitoring (i) control arm: standard of care with annual 24 h or 5-day Holter monitor or (ii) treatment arm: continuous cardiac monitoring with ILR implantation plus standard of care. Participants will undergo multiple investigations - blood/urine biomarkers, 12-lead and advanced electrocardiogram (ECG) recording, echocardiography and cardiovascular magnetic resonance (CMR) imaging - at baseline and 6-12 monthly follow-up visits. The primary endpoint is identification of arrhythmia requiring initiation or alteration in therapy. Secondary outcome measures include characterising the risk factors associated with arrhythmia and outcome data in the form of imaging, ECG and blood biomarkers. Discussion: This is the first study evaluating arrhythmia burden and the use of ILR across the spectrum of risk profiles in Fabry cardiomyopathy. This will enable detailed characterisation of arrhythmic risk predictors in FD and ultimately support formulation of Fabry-specific guidance in this high-risk population. Trial registration: ClinicalTrials.gov (NCT03305250). Registered on 9 October 2017

    Study of indications for cardiac device implantation and utilisation in Fabry cardiomyopathy

    Get PDF
    Background: Fabry disease is a treatable X-linked condition leading to progressive cardiomyopathy, arrhythmia and premature death. Atrial and ventricular arrhythmias contribute significantly to adverse prognosis; however, guidance to determine which patients require cardiovascular implantable electronic devices (CIEDs) is sparse. We aimed to evaluate indications for implantation practice in the UK and quantify device utilisation. Methods: In this retrospective study, we included demographic, clinical and imaging data from patients in four of the largest UK Fabry centres. Ninety patients with Fabry disease were identified with CIEDs implanted between June 2001 and February 2018 (FD-CIED group). To investigate differences in clinical and imaging markers between those with and without devices, these patients were compared with 276 patients without a CIED (FD-control). Results: In the FD-CIED group, 92% of patients with permanent pacemakers but only 28% with implantable cardioverter-defibrillators had a class 1 indication for implantation. A further 44% of patients had defibrillators inserted for primary prevention outside of current guidance. The burden of arrhythmia requiring treatment in the FD-CIED group was high (asymptomatic atrial fibrillation: 29%; non-sustained ventricular tachycardia requiring medical therapy alone: 26%; sustained ventricular tachycardia needing anti-tachycardia pacing/defibrillation: 28%). Those with devices were older, had greater LV mass, more scar tissue and larger atrial size. Conclusions: Arrhythmias are common in Fabry patients. Those with cardiac devices had high rates of atrial fibrillation requiring anticoagulation and ventricular arrhythmia needing device treatment. These are as high as those in hypertrophic cardiomyopathy, supporting the need for Fabry-specific indications for device implantation

    Cardiac device implantation and device usage in Fabry and hypertrophic cardiomyopathy

    Get PDF
    Background: Fabry disease (FD) is a treatable X-linked condition leading to progressive cardiac disease, arrhythmia and premature death. We aimed to increase awareness of the arrhythmogenicity of Fabry cardiomyopathy, by comparing device usage in patients with Fabry cardiomyopathy and sarcomeric HCM. All Fabry patients with an implantable cardioverter defibrillator (ICD) implanted in the UK over a 17 year period were included. A comparator group of HCM patients, with primary prevention ICD implantation, were captured from a regional registry database. Results: Indications for ICD in FD varied with 72% implanted for primary prevention based on multiple potential risk factors. In FD and HCM primary prevention devices, arrhythmia occurred more frequently in FD over shorter follow-up (HR 4.2, p < 0.001). VT requiring therapy was more common in FD (HR 4.5, p = 0.002). Immediate shock therapy for sustained VT was also more common (HR 2.5, p < 0.001). There was a greater burden of AF needing anticoagulation and NSVT in FD (AF: HR 6.2, p = 0.004, NSVT: HR 3.1, p < 0.001). Conclusion: This study demonstrates arrhythmia burden and ICD usage in FD is high, suggesting that Fabry cardiomyopathy may be more ‘arrhythmogenic’ than previously thought. Existing risk models cannot be mutually applicable and further research is needed to provide clarity in managing Fabry patients with cardiac involvement

    A case of airway obstruction secondary to acute haemorrhage into a benign thyroid cyst.

    Get PDF
    A 70-year-old female, with a history of progressive dyspnoea, was admitted to the critical care unit after successful resuscitation following a witnessed, out of hospital cardiorespiratory arrest. A presumptive diagnosis of cardiorespiratory arrest secondary to an exacerbation of chronic obstructive pulmonary disease was made. However, on more detailed examination a large anterior, midline neck mass was noted. Following tracheal intubation, a computerised tomography scan of the patient's neck and thorax revealed a seven-centimetre, well-defined, nonenhancing, rounded homogeneous opacity at the thoracic inlet, consistent with a large midline thyroid cyst. Needle aspiration of the cyst was performed and yielded approximately 50 mL of frank blood. After an uncomplicated tracheal extubation and recovery, an elective subtotal thyroidectomy was performed prior to hospital discharge. Histology of the specimen revealed a benign thyroid cyst within a multinodular goitre. Euthyroid multinodular goitres are more likely to be managed conservatively due to an asymptomatic clinical course in most patients. However, the risk of respiratory distress and acute airway obstruction from tracheal compression or acute haemorrhage should be kept in mind. Patients at risk of this life threatening complication should be managed with elective thyroidectomy to reduce morbidity and mortality
    corecore