10 research outputs found

    Bond Strength and Interfacial Ultramorphology of Current Adhesive Systems

    No full text
    Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)This study evaluated the bond strength and ultramorphology of the resin-dentin interfaces produced by current dental adhesive systems. Nine dentin bonding agents were investigated. Restored teeth were vertically, serially sectioned to obtain bonded slices for interfacial TEM analysis or to produce bonded beams for the microtensile bond strength test. The one-step self-etching adhesives (Futurabond (R) NR and Hybrid Bond (R)) showed lower bond strength values than the three-step etch-&-rinse adhesive system All-Bond 3. Most bonding agents presented statistically similar mean bond strength values, which ranged from 41.3 +/- 17.9 to 35.0 +/- 5.3 MPa. The thickness of the hybrid layer varied according to the type of adhesive system used. While the etch and rinse adhesives with alcohol as organic solvent showed bond strength means higher than 40 MPa, the self-etching systems showed bond strength lower than 40 MPa. Resin-dentin inter-difusion zone and resin tags were noted in all bonded interfaces.871211481166National Council for Research and Development [474670/2006-6, 303587/2007-5]Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)National Council for Research and Development [474670/2006-6, 303587/2007-5]FAPESP [05/60697-9, 07/06083-4

    Interfacial Ultramorphology Evaluation of Resin Luting Cements to Dentin: A Correlative Scanning Electron Microscopy and Transmission Electron Microscopy Analysis

    No full text
    Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)The objective of this study was to analyze the dentin-resin cements interfacial ultramorphologies using two different methods: scanning (SEM) and transmission electron microscopy (TEM). Four commercial products were evaluated: two conventional cementing system (RelyX ARC/Adper Scotchbond Multi-Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/DC Bond, Kuraray) and two self-adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Cement, Kuraray). Prepolymerized resin disks (Sinfony, 3M ESPE) were cemented on oclusal dentin surfaces of 24 third human molars, simulating the indirect restorations. After 24 h, teeth were sectioned into 0.9-mm thick slabs and processed for microscopy analyses (SEM or TEM/ n = 3). Qualitative characterization of dentin-resin cement interface was performed. Hybrid layer formation with long and dense resin tags was observed only for RelyX ARC cementing system. Clearfil Esthetic Cement/DC Bond system revealed few and short resin tags formation, whereas no hybridization and resin tags were detected for self-adhesive resin cements. Some interfacial regions exhibited that the self-adhesive resin cements were not bonded to dentin, presenting bubbles or voids at the interfaces. In conclusion, TEM and SEM bonding interface analyses showed ultramorphological variations among resin cements, which are directly related to dental bonding strategies used for each resin cement tested. Microsc. Res. Tech. 76:1234-1239, 2013. (c) 2013 Wiley Periodicals, Inc.761212341239Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)FAPESP [09/51281-4, 09/51674-6

    Effects of the solvent evaporation technique on the degree of conversion of one-bottle adhesive systems

    No full text
    This study evaluated the effect of four methods of solvent evaporation on the degree of conversion (DC) of seven one-bottle adhesive systems: Excite (EX), ONE-STEP (OS), Optibond Solo Plus (OB), Prime&Bond 2.1 (PB), Prime&Bond NT (NT), Single Bond (SB) and Single Bond Plus (SP) using Fourier Transform Infrared Analysis (FTIR). Adhesive resins were: 1) applied to KBr pellet surfaces and left undisturbed for 30 seconds (condition 1), 2) left undisturbed for 30 seconds and air-dried with an air stream for 10 seconds (condition 2), 3) left undisturbed for 60 seconds (condition 3) and 4) left undisturbed for 60 seconds and air-dried for 10 seconds (condition 4) before curing. FTIR spectra were obtained and the DC was calculated by comparing the ratio of aliphatic/aromatic double carbon bonds before and after light-activation for 10 seconds (XL 3000, 3M). The results of each product were analyzed by one-way repeated measure ANOVA and post-hoc Tukey's test (p < 0.05). The DC of PB, NT, OB and SP adhesives was not affected by the four evaporation conditions, while the DC of EX, OS and SB changed according to the evaporation method. The results suggested that the DC of some adhesives was similar regardless of the evaporation method when no water from dentin or rinsing was involved. Other bonding agents showed higher DC after specific conditions of solvent evaporation.33214915
    corecore