34 research outputs found

    Oxygen reduction in acid media: effect of iron substitution by cobalt on heat-treated naphthalocyanine impregnations supported on preselected carbon blacks

    Get PDF
    FeNPc(1.2) impregnations were investigated at various loadings using a rotating-disk electrode, voltammetry and X-ray photoelectron spectroscopy (XPS) techniques. Optimal activity takes place at monolayer coverage, and major demetallation occurs after prolonged exposure to acid solution. The substitution of Fe by Co enables the electrochemical performances to reach those presented by 10% Pt on Vulcan and stops the demetallation process. The application of fast atomic bombardment secondary ion mass spectrometry (FABS) together with XPS sheds light on the detrimental role of some electrophilic groups attached to the carbon black-catalyst interface

    Oxygen reduction in acid media: influence of the heat treatment on the FeNPc(1–20 isomer mixture impregnated on carbon blacks and active charcoals

    Get PDF
    Oxygen reduction with the aid of a number of FeNPc(1–2) impregnated carbon supports in sulphuric acid solutions has been investigated.\ud \ud Loading of the carbon samples amounted to about 10 wt.%. After a 10 day stay in the aerated solutions the samples were investigated with rotating disk electrode and X-ray photoelectron spectroscopy techniques. The most active and stable samples correspond to mono- or submonolayers of FeNPc deposited on high dibutylphthalate adsorption carbon blacks. Comparison with data obtained previously on Norit BrX impregnations emphasizes the rôle of the electron density on the inner nitrogen atoms rather than that on the iron centres

    Oxygen reduction in acid media on supported iron naphthalocyanine: Effect of isomer configuration and pyrolysis

    Get PDF
    O2 reduction in H2SO4 medium has been investigated on FeNPc impregnations on Norit BrX by the rotating disk electrode technique. Important differences in activity and stability were found between the 1,2- and 2,3-FeNPc isomers (pyrolysed or not). XPS analyses show, for the most inactive sample, strong demetallation and nitrogen losses. This phenomenon can be attributed to the differences in flexibility between the FeNPc isomers, which influences their stabilization on the substrate

    Oxygen reduction in an acid medium : electrocatalysis by CoNPc(1,2) impregnated on a carbon black support; effect of loading and heat treatment

    Get PDF
    O2 reduction in an acid medium has been investigated on a transition metal macrocycle, CoNPc(1,2), impregnated on a carbon black support with a high dibutylphthalate adsorption value, using a rotating disk electrode and voltammetry techniques described previously, combined with X-ray photoelectron spectroscopy measurements. Optimal activity was found for a bilayer coverage (n = 2) at 17%-18% w/w loading. Heat treatment seems to be beneficial for n 3: it increases the overall number N of exchanged electrons and improves the electrode wetting. For the most active samples, mixed Co(II)/Co(III) valencies were displayed

    Factors influencing speech perception in adults with a cochlear implant

    Get PDF
    Objectives: The primary objective of this study is to identify the biographic, audiologic, and electrode position factors that influence speech perception performance in adult cochlear implant (CI) recipients implanted with a device from a single manufacturer. The secondary objective is to investigate the independent association of the type of electrode (precurved or straight) with speech perception. Design: In a cross-sectional study design, speech perception measures and ultrahigh-resolution computed tomography scans were performed in 129 experienced CI recipients with a postlingual onset of hearing loss. Data were collected between December 2016 and January 2018 in the Radboud University Medical Center, Nijmegen, the Netherlands. The participants received either a precurved electrode (N = 85) or a straight electrode (N = 44), all from the same manufacturer. The biographic variables evaluated were age at implantation, level of education, and years of hearing loss. The audiometric factors explored were preoperative and postoperative pure-tone average residual hearing and preoperative speech perception score. The electrode position factors analyzed, as measured from images obtained with the ultrahigh-resolution computed tomography scan, were the scalar location, angular insertion depth of the basal and apical electrode contacts, and the wrapping factor (i.e., electrode-to-modiolus distance), as well as the type of electrode used. These 11 variables were tested for their effect on three speech perception outcomes: consonant-vowel-consonant words in quiet tests at 50 dB SPL (CVC50) and 65 dB SPL (CVC65), and the digits-in-noise test. Results: A lower age at implantation was correlated with a higher CVC50 phoneme score in the straight electrode group. Other biographic variables did not correlate with speech perception. Furthermore, participants implanted with a precurved electrode and who had poor preoperative hearing thresholds performed better in all speech perception outcomes than the participants implanted with a straight electrode and relatively better preoperative hearing thresholds. After correcting for biographic factors, audiometric variables, and scalar location, we showed that the precurved electrode led to an 11.8 percentage points (95% confidence interval: 1.4-20.4%; p = 0.03) higher perception score for the CVC50 phonemes compared with the straight electrode. Furthermore, contrary to our initial expectations, the preservation of residual hearing with the straight electrode was poor, as the median preoperative and the postoperative residual hearing thresholds for the straight electrode were 88 and 122 dB, respectively. Conclusions: Cochlear implantation with a precurved electrode results in a significantly higher speech perception outcome, independent of biographic factors, audiometric factors, and scalar location.Neuro Imaging Researc

    Hydropic ear disease: correlation between audiovestibular symptoms, endolymphatic hydrops and blood-labyrinth barrier impairment

    Get PDF
    Research Objective: To investigate the correlation between clinical features and MRI-confirmed endolymphatic hydrops (EH) and blood-labyrinth barrier (BLB) impairment.Study Design: Retrospective cross-sectional study.Setting: Vertigo referral center (Haga Teaching Hospital, The Hague, the Netherlands).Methods: We retrospectively analyzed all patients that underwent 4 h-delayed Gd-enhanced 3D FLAIR MRI at our institution from February 2017 to March 2019. Perilymphatic enhancement and the degree of cochlear and vestibular hydrops were assessed. The signal intensity ratio (SIR) was calculated by region of interest analysis. Correlations between MRI findings and clinical features were evaluated.Results: Two hundred and fifteen patients with MRI-proven endolymphatic hydrops (EH) were included (179 unilateral, 36 bilateral) with a mean age of 55.9 yrs and median disease duration of 4.3 yrs. Hydrops grade is significantly correlated with disease duration (P < 0.001), the severity of low- and high-frequency hearing loss (both P < 0.001), and the incidence of drop attacks (P = 0.001). Visually increased perilymphatic enhancement was present in 157 (87.7%) subjects with unilateral EH. SIR increases in correlation with hydrops grade (P < 0.001), but is not significantly correlated with the low or high Fletcher index (P = 0.344 and P = 0.178 respectively). No significant differences were found between the degree of EH or BLB impairment and vertigo, tinnitus or aural fullness.Conclusion: The degree of EH positively correlates with disease duration, hearing loss and the incidence of drop attacks. The BLB is impaired in association with EH grade, but without clear contribution to the severity of audiovestibular symptoms.Neuro Imaging Researc
    corecore