7 research outputs found

    Reliability assessment of ultrasound muscle echogenicity in patients with rheumatic diseases: Results of a multicenter international web-based study

    Get PDF
    ObjectivesTo investigate the inter/intra-reliability of ultrasound (US) muscle echogenicity in patients with rheumatic diseases.MethodsForty-two rheumatologists and 2 radiologists from 13 countries were asked to assess US muscle echogenicity of quadriceps muscle in 80 static images and 20 clips from 64 patients with different rheumatic diseases and 8 healthy subjects. Two visual scales were evaluated, a visual semi-quantitative scale (0–3) and a continuous quantitative measurement (“VAS echogenicity,” 0–100). The same assessment was repeated to calculate intra-observer reliability. US muscle echogenicity was also calculated by an independent research assistant using a software for the analysis of scientific images (ImageJ). Inter and intra reliabilities were assessed by means of prevalence-adjusted bias-adjusted Kappa (PABAK), intraclass correlation coefficient (ICC) and correlations through Kendall’s Tau and Pearson’s Rho coefficients.ResultsThe semi-quantitative scale showed a moderate inter-reliability [PABAK = 0.58 (0.57–0.59)] and a substantial intra-reliability [PABAK = 0.71 (0.68–0.73)]. The lowest inter and intra-reliability results were obtained for the intermediate grades (i.e., grade 1 and 2) of the semi-quantitative scale. “VAS echogenicity” showed a high reliability both in the inter-observer [ICC = 0.80 (0.75–0.85)] and intra-observer [ICC = 0.88 (0.88–0.89)] evaluations. A substantial association was found between the participants assessment of the semi-quantitative scale and “VAS echogenicity” [ICC = 0.52 (0.50–0.54)]. The correlation between these two visual scales and ImageJ analysis was high (tau = 0.76 and rho = 0.89, respectively).ConclusionThe results of this large, multicenter study highlighted the overall good inter and intra-reliability of the US assessment of muscle echogenicity in patients with different rheumatic diseases

    How is the ultrasound in rheumatology used, implemented, and applied in Latin American centers? Results from a multicenter study

    No full text
    This study aimed to perform an overview of how ultrasound (US) is being used, implemented, and applied in rheumatologic centers in Latin America (LA). A retrospective, multicenter 1-year experience study was undertaken. Eighteen centers from eight countries were involved. The following information were collected: demographic data, indication to perform an US examination, physician that required the examination, and the anatomical region required for the examination. A total of 7167 patients underwent an US examination. The request for US examinations came most frequently from their own institution (5981 (83.45 %)) than from external referral (1186 (16.55 %)). The services that more frequently requested an US examination were rheumatology 5154 (71.91 %), followed by orthopedic 1016 (14.18 %), and rehabilitation 375 (5.23 %). The most frequently scanned area was the shoulder in 1908 cases (26.62 %), followed by hand 1754 (24.47 %), knee 1518 (21.18 %), ankle 574 (8.01 %), and wrist 394 (5.50 %). Osteoarthritis was the most common disease assessed (2279 patients (31.8 %)), followed by rheumatoid arthritis (2125 patients (29.65 %)), psoriatic arthritis (869 patients (12.1 %)), painful shoulder syndrome (545 (7.6 %)), connective tissue disorders (systemic sclerosis 339 (4.7 %), polymyositis/dermatomyositis 107 (1.4 %), Sjögren’s syndrome 60 (0.8 %), and systemic lupus erythematosus 57 (0.8 %)). US evaluation was more frequently requested for diagnostic purposes (3981 (55.5 %)) compared to follow-up studies (2649 (36.9 %)), research protocols (339 (4.73 %)), and invasive guided procedures (198 (2.76 %)). US registered increasing applications in rheumatology and highlighted its positive impact in daily clinical practice. US increases the accuracy of the musculoskeletal clinical examination, influence the diagnosis, and the disease management. © 2016, International League of Associations for Rheumatology (ILAR)

    How is the ultrasound in rheumatology used, implemented, and applied in Latin American centers? Results from a multicenter study

    No full text
    This study aimed to perform an overview of how ultrasound (US) is being used, implemented, and applied in rheumatologic centers in Latin America (LA). A retrospective, multicenter 1-year experience study was undertaken. Eighteen centers from eight countries were involved. The following information were collected: demographic data, indication to perform an US examination, physician that required the examination, and the anatomical region required for the examination. A total of 7167 patients underwent an US examination. The request for US examinations came most frequently from their own institution (5981 (83.45 %)) than from external referral (1186 (16.55 %)). The services that more frequently requested an US examination were rheumatology 5154 (71.91 %), followed by orthopedic 1016 (14.18 %), and rehabilitation 375 (5.23 %). The most frequently scanned area was the shoulder in 1908 cases (26.62 %), followed by hand 1754 (24.47 %), knee 1518 (21.18 %), ankle 574 (8.01 %), and wrist 394 (5.50 %). Osteoarthritis was the most common disease assessed (2279 patients (31.8 %)), followed by rheumatoid arthritis (2125 patients (29.65 %)), psoriatic arthritis (869 patients (12.1 %)), painful shoulder syndrome (545 (7.6 %)), connective tissue disorders (systemic sclerosis 339 (4.7 %), polymyositis/dermatomyositis 107 (1.4 %), Sjögren’s syndrome 60 (0.8 %), and systemic lupus erythematosus 57 (0.8 %)). US evaluation was more frequently requested for diagnostic purposes (3981 (55.5 %)) compared to follow-up studies (2649 (36.9 %)), research protocols (339 (4.73 %)), and invasive guided procedures (198 (2.76 %)). US registered increasing applications in rheumatology and highlighted its positive impact in daily clinical practice. US increases the accuracy of the musculoskeletal clinical examination, influence the diagnosis, and the disease management. © 2016, International League of Associations for Rheumatology (ILAR)

    Reliability assessment of ultrasound muscle echogenicity in patients with rheumatic diseases: Results of a multicenter international web-based study

    No full text
    Objectives: To investigate the inter/intra-reliability of ultrasound (US) muscle echogenicity in patients with rheumatic diseases. Methods: Forty-two rheumatologists and 2 radiologists from 13 countries were asked to assess US muscle echogenicity of quadriceps muscle in 80 static images and 20 clips from 64 patients with different rheumatic diseases and 8 healthy subjects. Two visual scales were evaluated, a visual semi-quantitative scale (0-3) and a continuous quantitative measurement ("VAS echogenicity," 0-100). The same assessment was repeated to calculate intra-observer reliability. US muscle echogenicity was also calculated by an independent research assistant using a software for the analysis of scientific images (ImageJ). Inter and intra reliabilities were assessed by means of prevalence-adjusted bias-adjusted Kappa (PABAK), intraclass correlation coefficient (ICC) and correlations through Kendall's Tau and Pearson's Rho coefficients. Results: The semi-quantitative scale showed a moderate inter-reliability [PABAK = 0.58 (0.57-0.59)] and a substantial intra-reliability [PABAK = 0.71 (0.68-0.73)]. The lowest inter and intra-reliability results were obtained for the intermediate grades (i.e., grade 1 and 2) of the semi-quantitative scale. "VAS echogenicity" showed a high reliability both in the inter-observer [ICC = 0.80 (0.75-0.85)] and intra-observer [ICC = 0.88 (0.88-0.89)] evaluations. A substantial association was found between the participants assessment of the semi-quantitative scale and "VAS echogenicity" [ICC = 0.52 (0.50-0.54)]. The correlation between these two visual scales and ImageJ analysis was high (tau = 0.76 and rho = 0.89, respectively). Conclusion: The results of this large, multicenter study highlighted the overall good inter and intra-reliability of the US assessment of muscle echogenicity in patients with different rheumatic diseases

    Reliability assessment of the definition of ultrasound enthesitis in SpA: results of a large, multicentre, international web-based study

    No full text
    Objectives: To investigate the reliability of the OMERACT ultrasound (US) Task Force definition of US enthesitis in spondyloarthritis (SpA). Methods: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA [hypoechoic areas, entheseal thickening, power Doppler signal (PD) at the enthesis, enthesophytes/calcifications, bone erosions] were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries.Inter and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence and Bias Adjusted Kappa (PABAK) and their 95% confidence intervals. Results: Bone erosions and PD showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. Conclusions: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, PD, and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis

    Reliability of OMERACT ultrasound elementary lesions in gout: results from a multicenter exercise

    No full text
    corecore