43 research outputs found

    Measurement properties of UCLA Activity Scale for hip and knee arthroplasty patients and translation and cultural adaptation into Danish

    Get PDF
    Background and purpose — The UCLA Activity Scale (UCLA) is a questionnaire assessing physical activity level from 1 (low) to 10 (high) in patients undergoing hip or knee arthroplasty (HA/KA). After translation and cultural adaptation, we evaluated the measurement properties of the Danish UCLA. Patients and methods — After dual panel translation, cognitive interviews were performed among 55 HA/KA patients. An orthopedic surgeon and a physiotherapist estimated UCLA scores for 80 KA patients based on short interviews. Measurement properties were evaluated in 130 HA and 134 KA patients preoperatively and 1-year postoperatively. Results — To suit Danish patients of today, several adaptations were required. Prior to interviews, 4 patients were excluded, and 11 misinterpreted the answer options. Examiners rated the remaining 65 patients (mean age 67 years) 0.2–1.6 UCLA levels lower than patients themselves. The 130 HA and 134 KA patients (mean age 71/68 years) changed from 4.3 (SD 1.9)/4.5 (1.8) preoperatively to 6.6 (1.8)/6.2 (1.0) at 1-year follow-up. 103 (79%) HA and 89 (66%) KA patients reported increased activity. Effect sizes were large (1.2/0.96). Knee patients reaching minimal important change (MIC, ≥ 8 Oxford Knee Score points) had higher 1-year UCLA scores than patients not reaching MIC. Interpretation — Original scale development was undocumented. Content validity was questionable, and there was discrepancy between patient and examiner estimates. UCLA appears valuable for measuring change in self-reported physical activity on a group level. 4 out of 5 HA patients and 2 out of 3 KA patients were more physically active 1 year after joint replacement surgery

    Does choice of bearings influence the survival of cement-less total hip arthroplasty in patients aged 20–55 years? : Comparison of 21,594 patients reported to the Nordic Arthroplasty Register Association dataset 2005–2017

    Get PDF
    Background and purpose — The bearings with the best survivorship for young patients with total hip arthroplasty (THA) should be identified. We compared hazard ratios (HR) of revision of primary stemmed cementless THAs with metal-on-metal (MoM), ceramic-on-ceramic (CoC), and ceramic-on-highly-crosslinked-polyethylene (CoXLP) with that of metal-on-highly-crosslinked-polyethylene (MoXLP) bearings in patients aged 20–55 years with primary osteoar-thritis or childhood hip disorders. Patients and methods — From the Nordic Arthroplasty Register Association dataset we included 1,813 MoM, 3,615 CoC, 5,947 CoXLP, and 10,219 MoXLP THA in patients operated on between 2005 and 2017 in a prospective cohort study. We used the Kaplan–Meier estimator for THA sur-vivorship and Cox regression to estimate HR of revision adjusted for confounders (including 95% confidence intervals [CI]). MoXLP was used as reference. HRs were calcu-lated during 3 intervals (0–2, 2–7, and 7–13 years) to meet the assumption of proportional hazards. Results — Median follow-up was 5 years for MoXLP, 10 years for MoM, 6 years for CoC, and 4 years for CoXLP. 13-year Kaplan–Meier survival estimates were 95% (CI 94–95) for MoXLP, 82% (CI 80–84) for MoM, 93% (CI 92–95) for CoC, and 93% (CI 92–94) for CoXLP bearings. MoM had higher 2–7 and 7–13 years’ adjusted HRs of revi-sion (3.6, CI 2.3–5.7 and 4.1, CI 1.7–10). MoXLP, CoC, and CoXLP had similar HRs in all 3 periods. The 7–13-year adjusted HRs of revision of CoC and CoXLP were statisti-cally non-significantly higher. Conclusion — In young patients, MoXLP for primary cementless THA had higher revision-free survival and lower HR for revision than MoM bearings. Longer follow-up is needed to compare MoXLP, CoC, and CoXLP.Peer reviewe

    Lawson criterion for ignition exceeded in an inertial fusion experiment

    Get PDF
    For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin "burn propagation" into surrounding cold fuel, enabling the possibility of high energy gain. While "scientific breakeven" (i.e., unity target gain) has not yet been achieved (here target gain is 0.72, 1.37 MJ of fusion for 1.92 MJ of laser energy), this Letter reports the first controlled fusion experiment, using laser indirect drive, on the National Ignition Facility to produce capsule gain (here 5.8) and reach ignition by nine different formulations of the Lawson criterion

    Lawson Criterion for Ignition Exceeded in an Inertial Fusion Experiment

    Get PDF

    Evaluation of the Oxford Hip Score:Does it still have content validity? Interviews of total hip arthroplasty patients

    No full text
    Abstract Background The Oxford Hip Score is used to evaluate the outcome after total hip arthroplasty. The Oxford Hip Score was developed more than 20 years ago with only some degree of patient involvement. We question if the Oxford Hip Score is still relevant for the present-day total hip artrhoplasty patients. We aimed to determine whether the Oxford Hip Score contains items that are relevant for present-day patients with osteoarthritis undergoing total hip arthroplasty, thus investigating the content validity. Methods Patients aged 60–75 years, undergoing total hip arthroplasty for primary osteoarthritis were recruited to participate in focus group interviews preoperatively and at 3 and 12 months after primary total hip arthroplasty. We conducted 6 focus group interviews in which 30 patients participated. The interviews were audio-recorded and transcribed verbatim. Using Interpretative Phenomenological Analysis, we inductively organised the interview transcripts into particular items/themes which we then compared to items in the Oxford Hip Score. Results We identified 6 general items with 41 sub-items. The 6 general items were pain, walking, physical activities, functional abilities, quality of life and psychological health. We found that items in the Oxford Hip Score were all in some way relevant to the patients but that the Oxford Hip Score lacks several important items relevant for present-day total hip artrhoplasty patients, including several physical activities, functional abilities and certain aspects of quality of life and psychological health. Conclusion We found that the Oxford Hip Score lacks important items for present-day patients in our population. Due to findings regarding several additional items that are not present in the Oxford Hip Score, particularly concerning physical activities and quality of life, we question the content validity of the Oxford Hip Score for a present-day population. Our findings indicate a need for a revision of the Oxford Hip Score

    Do different types of bearings and noise from total hip arthroplasty influence hip-related pain, function, and quality of life postoperatively?: A cross-sectional study from the Danish Hip Arthroplasty Registry

    Get PDF
    Background and purpose — Patient-reported outcome (PRO) is recognized as an important tool for evaluating the outcome and satisfaction after total hip arthroplasty (THA). We wanted to compare patient-reported outcome measure (PROM) scores from patients with ceramic-on-ceramic (CoC) THAs and those with metal-on-metal (MoM) THAs to scores from patients with metal-on-polyethylene (MoP) THAs, and to determine the influence of THA-related noise on PROM scores. Patients and methods — We conducted a nationwide cross-sectional questionnaire survey in a cohort of patients identified from the Danish Hip Arthroplasty Registry. The PROMs included were: hip dysfunction and osteoarthritis and outcome score (HOOS), EQ-5D-3L, EQ VAS, UCLA activity score, and questions about noise from the THA. The response rate was 85% and the number of responders was 3,089. Of these, 45% had CoC THAs, 17% had MoM THAs, and 38% had MoP THAs, with a mean length of follow-up of 7, 5, and 7 years, respectively. Results — Compared to MoP THAs, the mean PROM scores for CoC and MoM THAs were similar, except that CoC THAs had a lower mean score for HOOS Symptoms than did MoP THA. 27% of patients with CoC THAs, 29% with MoM THAs, and 12% with MoP THAs reported noise from their hip. For the 3 types of bearings, PROM scores from patients with a noisy THA were statistically significantly worse than those from patients with a silent MoP THA. The exception was noisy CoC and MoM THAs, which had the same mean UCLA activity score as silent MoP THAs. Interpretation — A high proportion of patients reported noise from the THA, and these patients had worse PROM scores than patients with silent MoP THAs
    corecore