5 research outputs found

    Microsampling and enantioselective liquid chromatography coupled to mass spectrometry for chiral bioanalysis of novel psychoactive substances

    Get PDF
    In this paper, the development of efficient enantioselective HPLC methods for the analysis of five benzofuran-substituted phenethylamines, two substituted tryptamines, and three substituted cathinones is described. For the first time, reversed-phase (eluents made up with acidic water-methanol solutions) and polar-ionic (eluent made up with an acetonitrile-methanol solution incorporating both an acidic and a basic additive) conditions fully compatible with mass spectrometry (MS) detectors were applied with a chiral stationary phase (CSP) incorporating the (+)-(18-crown-6)-tetracarboxylic acid chiral selector. Enantioresolution was achieved for nine compounds with α and RS factors up to 1.32 and 5.12, respectively. Circular dichroism (CD) detection, CD spectroscopy in stopped-flow mode and quantum mechanical (QM) calculations were successfully employed to investigate the absolute stereochemistry of mephedrone, methylone and butylone and allowed to establish a (R)<(S) enantiomeric elution order for these compounds on the chosen CSP. Whole blood miniaturized samples collected by means of volumetric absorptive microsampling (VAMS) technology and fortified with the target analytes were extracted following an optimized protocol and effectively analysed by means of an ultra-high performance liquid chromatography-MS system. By this way a proof-of-concept procedure was applied, demonstrating the suitability of the method for quali-quantitative enantioselective assessment of the selected psychoactive substances in advanced biological microsamples. VAMS microsamplers including a polypropylene handle topped with a small tip of a polymeric porous material were used and allowed to volumetrically collect small aliquots of whole blood (10 ÎĽL) independently from its density. Highly appreciable volumetric accuracy (bias, in the -8.7-8.1% range) and precision (% CV, in the 2.8-5.9% range) turned out

    Environmentally Sustainable Achiral and Chiral Chromatographic Analysis of Amino Acids in Food Supplements

    No full text
    Two LC methods were developed for the achiral and chiral reversed-phase (RP) analysis of an amino acid (AA) pool in a food supplement, in compliance with the main paradigms of Green Chromatography. A direct achiral ion-pairing RP-HPLC method was optimized under gradient conditions with a water-ethanol (EtOH) eluent containing heptafluorobutyric acid (0.1%, v/v), to quantify the eight essential AAs (Ile, Leu, Lys, Met, Phe, Thr, Trp, and Val) contained in the food supplement. Thus, the usually employed acetonitrile was profitably substituted with the less toxic and more benign EtOH. The method was validated for Leu and Phe. The chiral LC method performed with a teicoplanin chiral stationary phase was developed with a water-EtOH (60:40, v/v) eluent with 0.1%, v/v acetic acid. The enantioselective analysis was carried out without any prior derivatization step. Both developed methods performed highly for all eight AAs and revealed that: (i) the content of six out of eight AAs was consistent with the manufacturer declaration; (ii) only L-AAs were present. Furthermore, it was demonstrated that a two-dimensional achiral–chiral configuration is possible in practice, making it even more environmentally sustainable. A molecular modelling investigation revealed interesting insights into the enantiorecognition mechanism of Lys

    Environmentally Sustainable Achiral and Chiral Chromatographic Analysis of Amino Acids in Food Supplements

    No full text
    Two LC methods were developed for the achiral and chiral reversed-phase (RP) analysis of an amino acid (AA) pool in a food supplement, in compliance with the main paradigms of Green Chromatography. A direct achiral ion-pairing RP-HPLC method was optimized under gradient conditions with a water-ethanol (EtOH) eluent containing heptafluorobutyric acid (0.1%, v/v), to quantify the eight essential AAs (Ile, Leu, Lys, Met, Phe, Thr, Trp, and Val) contained in the food supplement. Thus, the usually employed acetonitrile was profitably substituted with the less toxic and more benign EtOH. The method was validated for Leu and Phe. The chiral LC method performed with a teicoplanin chiral stationary phase was developed with a water-EtOH (60:40, v/v) eluent with 0.1%, v/v acetic acid. The enantioselective analysis was carried out without any prior derivatization step. Both developed methods performed highly for all eight AAs and revealed that: (i) the content of six out of eight AAs was consistent with the manufacturer declaration; (ii) only L-AAs were present. Furthermore, it was demonstrated that a two-dimensional achiral–chiral configuration is possible in practice, making it even more environmentally sustainable. A molecular modelling investigation revealed interesting insights into the enantiorecognition mechanism of Lys

    Improved Achiral and Chiral HPLC-UV Analysis of Ruxolitinib in Two Different Drug Formulations

    No full text
    In this paper, two new reversed-phase (RP) HPLC-UV methods enabling the quantitative achiral and chiral analysis of ruxolitinib in commercial tablets (containing 20 mg of active pharmaceutical ingredient, API) and not commercially available galenic capsules (with 5 mg of API) are described. For the achiral method based on the use of a water/acetonitrile [70:30, v/v; with 0.1% (v) formic acid] eluent, a “research validation” study was performed mostly following the “International Council for Harmonization” guidelines. All the system suitability parameters were within the acceptance criteria: tailing factor, between 1.7 and 2.0; retention factor, 2.2; number of theoretical plates, >9000. The linearity curve showed R2 = 0.99 (Rxv2 = 0.99), while trueness (expressed as recovery) was between 96.3 and 106.3%. Coefficient of variations (CVs) (repeatability: CVw and intermediate precision: CVIP) did not exceed 1.3% and 2.9%, respectively. Moreover, the use of the enantiomeric Whelk-O1 chiral stationary phases operated under similar RP eluent conditions as for the achiral analyses, and the “inverted chirality columns approach (ICCA)” allowed us to establish that the enantiomeric purity of ruxolitinib is retained upon reformulation from tablets to capsules. The two developed methods can allow accurate determinations of ruxolitinib in drug formulations for medical use

    Multiple Heart-Cutting Two-Dimensional HPLC-UV Achiral–Chiral Analysis of Branched-Chain Amino Acids in Food Supplements under Environmentally Friendly Conditions

    No full text
    A multiple heart-cutting (mLC-LC) two-dimensional HPLC-UV achiral–chiral method for the direct analysis of branched-chain amino acids (BCAAs) in food supplements under environmentally friendly conditions was developed to cope with the very well-known limited chemoselectivity of chromatographic media for enantioselective analysis. Both achiral and chiral methods were developed in compliance with the main principles of green chromatography. The achiral analysis was performed isocratically with an optimized ion-pair reversed-phase (IP-RP) method based on a water/EtOH (95:5, v/v) mobile phase containing heptafluorobutyric acid (7 mM) as the IP agent. The achiral method was characterized by a very appreciable performance and was validated before the analysis of the real sample. High recovery values for all compounds (from 97% to 101%) were found in the interday evaluation. Additionally, low RSD% values in the long-term period were measured, in the range between 1.1% and 4.8%. Still, an LOQ value of 0.06 mg/mL was established for all compounds. The quantitative analysis of a commercial food supplement revealed that BCAAs were present in amounts very close to those declared by the producer. The enantioselective analysis was carried out through the application of the chiral ligand-exchange chromatography (CLEC) approach, using O-benzyl-(S)-serine ((S)-OBS, 0.5 mM) as the chiral selector and Cu(II) nitrate (0.25 mM) as the metal source in the eluent. Resolution and separation factor values up to 2.31 and 1.43, respectively, were obtained. The two chromatographic systems were connected through a six-port switching valve, and the developed two-dimensional mLC-LC method confirmed the absence of D-enantiomers of BCAAs in the food supplement, as reported in the manufacturer’s label
    corecore