21,070 research outputs found
Robust Beamforming for Secrecy Rate in Cooperative Cognitive Radio Multicast Communications
In this paper, we propose a cooperative approach to improve the security of
both primary and secondary systems in cognitive radio multicast communications.
During their access to the frequency spectrum licensed to the primary users,
the secondary unlicensed users assist the primary system in fortifying security
by sending a jamming noise to the eavesdroppers, while simultaneously protect
themselves from eavesdropping. The main objective of this work is to maximize
the secrecy rate of the secondary system, while adhering to all individual
primary users' secrecy rate constraints. In the case of passive eavesdroppers
and imperfect channel state information knowledge at the transceivers, the
utility function of interest is nonconcave and involved constraints are
nonconvex, and thus, the optimal solutions are troublesome. To address this
problem, we propose an iterative algorithm to arrive at a local optimum of the
considered problem. The proposed iterative algorithm is guaranteed to achieve a
Karush-Kuhn-Tucker solution.Comment: 6 pages, 4 figures, IEEE ICC 201
Towards spectral-domain optical coherence tomography on a silicon chip
Optical coherence tomography (OCT) is a widely used optical imaging technology, particularly in the medical field, since it can provide non-invasive, sub-micrometer resolution diagnostic images of tissue. Current OCT systems contain optical fibers and free-space optical components which make these instruments bulky and costly. A significant decrease in the size and cost of an OCT system is possible through the use of integrated optics, allowing for compact and low-cost OCT systems, especially suited for applications in which instrument size may play an important role. In this work, we present a miniaturized spectral-domain OCT (SD-OCT) system. We design an arrayed waveguide grating (AWG) spectrometer in silicon oxynitride for the 1300-nm spectral range. The spectral range of the SD-OCT system near 1300 nm is specifically selected for skin imaging. We aim at 18-μm depth resolution (determined by the full width at half maximum values of the transmission spectrum of the AWG) and a 1-mm depth range (determined by the wavelength spacing per output waveguide). The free spectral range of 78 nm and wavelength resolution of 0.4 nm of the AWG are determined to meet these requirements. We use ahe fiber-based SD-OCT system with AWG spectrometer. The Michelson interferometer is illuminated using a superluminescent diode which has a Gaussian-like spectrum with a bandwidth of 40 nm and a central wavelength of 1300 nm. Via a circulator the light is coupled into a 90/10 beamsplitter. Polarization controllers are placed into both, sample and reference arm. The backreflected light is redirected through the optical circulator to the AWG spectrometer. The collimated beam is imaged with a camera lens onto a 46 kHz CCD linescan camera. The acquired spectra are processed by first subtracting the reference arm spectrum, then compensating the dispersion, and finally resampling to k-space. We achieve a depth range of 1mm. The measured signal-to-noise ratio (SNR) is 75 dB. The axial resolution (FWHM) is determined from a Gaussian fit to the point spread function in amplitude at various depths. A slight decrease in depth resolution is observed at higher depth ranges, which we attribute to misalignment and lens aberrations. As a demonstration of OCT imaging using the AWG spectrometer, an image of a layered phantom is recorded. The phantom consists of three layers of scattering medium (µs = 4 mm-1, refractive index n = 1.41) interleaved with non-scattering tape. We can observe all three scattering layers up to the maximum imaging depth of 1 mm
Predictive analytics for detecting sensor failure using autoregressive integrated moving average model
© 2017 IEEE. Sensors play a vital role in monitoring the important parameters of critical infrastructure. Failure of such sensors causes destabilization to the entire system. In this regard, this paper proposes a predictive analytics solution for detecting the failure of a sensor that measures surface temperature from an urban sewer. The proposed approach incorporates a forecasting technique based on the past time series of sparse data using an autoregressive integrated moving average (ARIMA) model. Based on the 95% forecast interval and continuity of faulty data, a criterion was set to detect anomalies and to issue a warning for sensor failure. The forecasted and faulty data were assumed Gaussian distributed. By using the probability density of the distribution, the mean and variance were computed for faulty data to examine the abnormality in the variance value of each day to detect the sensor failure. The experimental results on the sewer temperature data are appealing
Design and characterization of SiON integrated optics components for optical coherence tomography
Optical coherence tomography (OCT) is a technique for high resolution imaging of biological tissues with a depth range of a few millimeters. OCT is based on interferometry to enable depth ranging. Currently, optical components for OCT are rather bulky and expensive; the use of integrated optical circuits presents a great opportunity to reduce costs and enhance system functionality and performance. We present the design and characterization of SiON-based integrated optics waveguides, splitters, couplers and interferometers for OCT operating at a wavelength of 1.3 um
QUANTITATIVE DETERMINATION AND PREPARATIVE ISOLATION OF TWO MAJOR ALKALOIDS FROM THE VIETNAMESE MEDICINAL HERB EVODIAE FRUCTUS
Objective: To develop a simple and accurate HPLC-DAD method for simultaneous determination, the content of major components: limonin, evodiamine, and rutaecarpine in Evodiae fructus and evaluation the quality of Evodiae fructus sold in markets.
Methods: Open column chromatography was used to separate and purify rutaecarpine and evodiamine, the two major alkaloids from Evodiae fructus extract as a laboratory standard. Chromatographic separation was achieved using a Germini C18 column (150 mm × 4.6 mm I.D., 5 µm), detected at 210 nm. The mobile phase consisted of acetonitrile (A), methanol (B), and water (C). The validated method simultaneously determined alkaloid content in 40 batches of samples collected from markets in different regions of Vietnam.
Results: In one-step purification, our method yielded 326 mg of rutaecarpine and 128 mg of evodiamine from 3.2 g of crude extract, with purities of 98.9 and 98.5%, respectively. The structures of these compounds were identified using 1H NMR and 13C NMR. There was a significant correlation between alkaloid content and fruit size, with a Spearman correlation coefficient of>0.5 (p<0.001), and there was a large difference in alkaloid contents between three maturity degrees of the fruit. Open-mouth fruits and fruits with average sizes of 4 to 6 mm had the highest alkaloid contents, whereas closed-mouth fruits had the lowest.
Conclusion: This study provided information on the standardization and quality control of evodiamine and rutaecarpine in Evodiae fructus, as well as a foundation for further pharmacological and toxicological studies
Ion-implantation induced anomalous surface amorphization in silicon
Spectroscopic ellipsometry (SE), high-depth-resolution Rutherford backscattering (RBS) and channeling have been used to examine the surface damage formed by room temperature N and B implantation into silicon. For the analysis of the SE data we used the conventional method of assuming appropriate optical models and fitting the model parameters (layer thicknesses and volume fraction of the amorphous silicon component in the layers) by linear regression. The dependence of the thickness of the surface-damaged silicon layer (beneath the native oxide layer) on the implantation parameters was determined: the higher the dose, the thicker the disordered layer at the surface. The mechanism of the surface amorphization process is explained in relation to the ion beam induced layer-by-layer amorphization. The results demonstrate the applicability of Spectroscopic ellipsometry with a proper optical model. RBS, as an independent cross-checking method supported the constructed optical model
- …