23 research outputs found

    Fast nuclear staining of head hair roots as a screening method for successful STR analysis in forensics

    Get PDF
    The success rate of STR profiling of hairs found at a crime scene is quite low and negative results of hair analysis are frequently reported. To increase the success rate of DNA analysis of hairs in forensics, nuclei in hair roots can be counted after staining the hair root with DAPI. Two staining methods were tested: a longer method with two 1 h incubations in respectively a DAPI-and a wash-solution, and a fast, direct staining of the hair root on microscope slides. The two staining methods were not significantly different. The results of the STR analysis for both procedures showed that 20 nuclei are necessary to obtain at least partial STR profiles. When more than 50 nuclei were counted, full STR profiles were always obtained. In 96% of the cases where no nuclei were detected, no STR profile could be obtained. However, 4% of the DAPI-negative hair roots resulted in at least partial STR profiles. Therefore, each forensic case has to be evaluated separately in function of the importance of the evidential value of the found hair. The fast staining method was applied in 36 forensic cases on 279 hairs in total. A fast screening method using DAPI can be used to increase the success rate of hair analysis in forensics

    Automatic detection of spermatozoa for laser capture microdissection

    Get PDF
    In sexual assault crimes, differential extraction of spermatozoa from vaginal swab smears is often ineffective, especially when only a few spermatozoa are present in an overwhelming amount of epithelial cells. Laser capture microdissection (LCM) enables the precise separation of spermatozoa and epithelial cells. However, standard sperm-staining techniques are non-specific and rely on sperm morphology for identification. Moreover, manual screening of the microscope slides is time-consuming and labor-intensive. Here, we describe an automated screening method to detect spermatozoa stained with Sperm HY-LITER (TM). Different ratios of spermatozoa and epithelial cells were used to assess the automatic detection method. In addition, real postcoital samples were also screened. Detected spermatozoa were isolated using LCM and DNA analysis was performed. Robust DNA profiles without allelic dropout could be obtained from as little as 30 spermatozoa recovered from postcoital samples, showing that the staining had no significant influence on DNA recovery

    Sources of DNA contamination and decontamination procedures in the forensic laboratory

    Get PDF
    The sensitivity of forensic DNA typing techniques can cause problems when evidence samples are inadvertently contaminated with DNA from another source. Therefore, precautions need to be taken to minimize the risk of contamination. In this study, laboratory air and surfaces, tools and equipment were evaluated as potential sources of contaminating DNA. Subsequently, two decontamination procedures, i.e. the conventionally used sodium hypochlorite and the commercially available DNA decontamination solution DNA ZAPTM (Applied Biosystems), were compared for their use in removing potentially contaminating DNA from the laboratory working environment. From our results, it can be concluded that air is unlikely to be the source of observed DNA contamination in the laboratory whereas DNA accumulating on surfaces, tools and equipment within the laboratory environment may potentially be transferred to evidence samples. DNA ZAPTM outperformed the conventionally used sodium hypochlorite decontamination procedure. Stringent preventive measures and decontamination of equipment and laboratory surfaces is important to avoid secondary transfer of this contaminating DNA to evidence samples

    Mass spectrometry-based proteomics as a tool to identify biological matrices in forensic science

    Get PDF
    In forensic casework analysis, identification of the biological matrix and the species of a forensic trace, preferably without loss of DNA, is of major importance. The biological matrices that can be encountered in a forensic context are blood (human or non-human), saliva, semen, vaginal fluid, and to a lesser extent nasal secretions, feces, and urine. All these matrices were applied on swabs and digested with trypsin in order to obtain peptides. These peptides were injected on a mass spectrometer (ESI Q-TOF) resulting in the detection of several biomarkers that were used to build a decision tree for matrix identification. Saliva and blood were characterized by the presence of alpha-amylase 1 and hemoglobin, respectively. In vaginal fluid, cornulin, cornifin, and/or involucrin were found as biomarkers while semenogelin, prostate-specific antigen, and/or acid phosphatase were characteristic proteins for semen. Uromodulin or AMBP protein imply the presence of urine, while plunc protein is present in nasal secretions. Feces could be determined by the presence of immunoglobulins without hemoglobin. The biomarkers for the most frequently encountered biological matrices (saliva, blood, vaginal fluid, and semen) were validated in blind experiments and on real forensic samples. Additionally, by means of this proteomic approach, species identification was possible. This approach has the advantage that the analysis is performed on the first "washing" step of the chelex DNA extraction, a solution which is normally discarded, and that one single test is sufficient to determine the identity and the species of the biological matrix, while the conventional methods require cascade testing. This technique can be considered as a useful additional tool for biological matrix identification in forensic science and holds the promise of further automation

    Forensic massively parallel sequencing data analysis tool: implementation of MyFLq as a standalone web- and Illumina BaseSpace®-application

    Get PDF
    Routine use of massively parallel sequencing (MPS) for forensic genomics is on the horizon. The last few years, several algorithms and workflows have been developed to analyze forensic MPS data. However, none have yet been tailored to the needs of the forensic analyst who does not possess an extensive bioinformatics background. We developed our previously published forensic MPS data analysis framework MyFLq (My-Forensic-Loci-queries) into an open-source, user-friendly, web-based application. It can be installed as a standalone web application, or run directly from the Illumina BaseSpace environment. In the former, laboratories can keep their data on-site, while in the latter, data from forensic samples that are sequenced on an Illumina sequencer can be uploaded to Basespace during acquisition, and can subsequently be analyzed using the published MyFLq BaseSpace application. Additional features were implemented such as an interactive graphical report of the results, an interactive threshold selection bar, and an allele length-based analysis in addition to the sequenced-based analysis. Practical use of the application is demonstrated through the analysis of four 16-plex short tandem repeat (STR) samples, showing the complementarity between the sequence- and length-based analysis of the same MPS data

    Suspension fluorescence in situ hybridization (S-FISH) combined with automatic detection and laser microdissection for STR profiling of male cells in male/female mixtures

    Get PDF
    Laser microdissection is a valuable tool for isolating specific cells from mixtures, such as male cells in a mixture with female cells, e.g., in cases of sexual assault. These cells can be stained with Y-chromosome-specific probes. We developed an automatic screening method to detect male cells after fluorescence in situ hybridization in suspension (S-FISH). To simulate forensic casework, the method was tested on female saliva after cataglottis (a kiss involving tongue-to-tongue contact) and on licking traces (swabs of dried male saliva on female skin) even after drying. After isolation of the detected cells, short tandem repeat profiling was performed. Full DNA profiles could consistently be obtained from as little as ten buccal cells. Isolation of five cells resulted in a mean of 98% (SD of 3.4%) of the alleles detected, showing that the developed S-FISH staining had no significant negative influence on DNA recovery and can be used in forensic casework
    corecore