    Tetrahydrofuran (co)polymers as potential materials for vascular prostheses

    Get PDF
    Polyethers were studied as potential materials for vascular prostheses. By crosslinking poly(tetramethylene oxide) (PTMO) with poly(ethylene oxide) (PEO), hydrophilic networks were obtained containing PTMO as well as PEO. Attempts were made to reduce the crystallinity and melting point of PTMO because of the required elastomeric behaviour at body temperature. Compared to non-crosslinked PTMO, crosslinking in the melt resulted in a decrease in the melting point from 43·7 to 38·7°C and a decrease of the crystallinity from 46 to 28%. By copolymerizing tetrahydrofuran with oxetane or dimethyloxetane, melting points below 38°C were obtained, together with crystallinities lower than 20%

    In vivo testing of crosslinked polyethers. II. Weight loss, IR analysis, and swelling behavior after implantation

    Get PDF
    As reported in Part I (In vivo testing of crosslinked polyethers. I. Tissue reactions and biodegradation, J. Biomed. Mater. Res., this issue, pp. 307-320), microscopical evaluation after implantation of crosslinked (co)polyethers in rats showed differences in the rate of biodegradation, depending on the presence of tertiary hydrogen atoms in the main chain and the hydrophilicity of the polyether system. In this article (Part II) the biostability will be discussed in terms of weight loss, the swelling behavior, and changes in the chemical structure of the crosslinked polyethers after implantation. The biostability increased in the order poly(POx) < poly(THF-co-OX) < poly(THF) for the relatively hydrophobic polyethers. This confirmed our hypothesis that the absence of tertiary hydrogen atoms would improve the biostability. On the other hand, signs of biodegradation were observed for all polyether system studied. Infrared surface analysis showed that biodegradation was triggered by oxidative attack on the polymeric chain, leading to the formation of carboxylic ester and acid groups. It also was found that in the THF-based (co)polyethers, α-methylene groups were more sensitive than β-methylene groups. For a hydrophilic poly(THF)/PEO blend, an increase in surface PEO content was found, which might be due to preferential degradation of the PEO domains

    In vivo testing of crosslinked polyethers. II:Weight loss, IR analysis and swelling behavior after implantation

    Get PDF
    As reported in Part I (In vivo testing of crosslinked polyethers. I. Tissue reactions and biodegradation, J. Biomed. Mater. Res., this issue, pp. 307-320), microscopical evaluation after implantation of crosslinked (co)polyethers in rats showed differences in the rate of biodegradation, depending on the presence of tertiary hydrogen atoms in the main chain and the hydrophilicity of the polyether system. In this article (Part II) the biostability will be discussed in terms of weight loss, the swelling behavior, and changes in the chemical structure of the crosslinked polyethers after implantation. The biostability increased in the order poly(POx) &lt; poly(THF-co-OX) &lt; poly(THF) for the relatively hydrophobic polyethers. This confirmed our hypothesis that the absence of tertiary hydrogen atoms would improve the biostability. On the other hand, signs of biodegradation were observed for all polyether system studied. Infrared surface analysis showed that biodegradation was triggered by oxidative attack on the polymeric chain, leading to the formation of carboxylic ester and acid groups. It also was found that in the THF-based (co)polyethers, α-methylene groups were more sensitive than β-methylene groups. For a hydrophilic poly(THF)/PEO blend, an increase in surface PEO content was found, which might be due to preferential degradation of the PEO domains

    Optical characterization and selective addressing of the resonant modes of a micropillar cavity with a white light beam

    Get PDF
    We have performed white-light reflectivity measurements on GaAs/AlAs micropillar cavities with diameters ranging from 1 {\mu}m up to 20 {\mu}m. We are able to resolve the spatial field distribution of each cavity mode in real space by scanning a small-sized beam across the top facet of each micropillar. We spectrally resolve distinct transverse optical cavity modes in reflectivity. Using this procedure we can selectively address a single mode in the multimode micropillar cavity. Calculations for the coupling efficiency of a small-diameter beam to each mode are in very good agreement with our reflectivity measurements.Comment: 7 pages, 8 figure

    In vivo testing of crosslinked polyethers. I:Tissue reactions and biodegradation

    Get PDF
    The in vivo biocompatibility and biodegradation of crosslinked (co)polyethers with and without tertiary hydrogen atoms in the main chain and differing in hydrophilicity were studied by means of subcutaneous implantation in rats. After 4 days, 1 month, and 3 months postimplantation, the tissue reactions and interactions were evaluated by light microscopy (LM) and transmission electron microscopy (TEM). Poly(tetrahydrofuran) (poly(THF)), poly(propylene oxide) (poly(POx)), and poly(tetrahydrofuran-co-oxetane) (poly-(THF-co-OX)) were tested as relatively hydrophobic polyethers, and poly(ethylene oxide) (PEO) and a poly(THF)/PEO blend were used as more hydrophilic materials. In general, all polyethers showed good biocompatibility with respect to tissue reactions and interactions, with low neutrophil and macrophage infiltration, a quiet giant cell reaction, and formation of a thin fibrous capsule. For the relatively hydrophobic polyethers studied, the biostability increased in the order poly(POx) &lt; poly(THF-co-OX) &lt; poly(THF), probably indicating that the absence of tertiary hydrogen atoms has a positive effect on the biostability. Concerning the more hydrophilic materials, crosslinked PEO showed the highest rate of degradation, probably due to the mechanical weakness of the hydrogel in combination with the highest presence of giant cells as a result of the high porosity. A frayed surface morphology was observed after implantation of the crosslinked poly(THF)/PEO blend, which might be due to preferential degradation of PEO domains
    • …