48 research outputs found
The spectral X-ray imaging data acquisition (SpeXIDAQ) framework
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of devices. A different class of PCD (Photon Counting Detector) devices has become generally available, where camera data output is no longer a matrix of photon counts but instead direct measurements of the deposited charge per pixel in every frame, which requires significant off-camera processing. This type of PCD, called a hyperspectral X-ray camera due to its fully spectroscopic output, yet again increases the demands put on the acquisition and processing backend. Not only are bandwidth requirements increased, but the need to do extensive data processing is also introduced with these hyperspectral PCD devices. To cope with these new developments the Spectral X-ray Imaging Data Acquisition framework (SpeXIDAQ) has been developed. All aspects of the imaging pipeline are handled by the SpeXIDAQ framework: from detector control and frame grabbing, to processing, storage and live visualisation during experiments
Implementation of a hyperspectral X-ray camera control and processing software chain
Hyperspectral X-ray detectors, which provide the full energy spectrum detected by each individual pixel, have become available for use in lab-based facilities. The addition of spectral information currently comes at the cost of low overall acceptable flux rates, and can introduce countrate nonlinearity at higher energies. Neither of these drawbacks are desirable for transmission imaging and tomography. In this paper a new data processing software chain is presented for the SLcam, a pnCCD-based hyperspectral camera prototype, allowing for more control over the conversion from raw frames to hyperspectral images. Complementary to the processing software, a set of live data visualisations was developed to aid in monitoring ongoing experiments and to allow for preliminary data processing on-the-fly. The combination of these software elements forms the first step towards general applicability of hyperspectral imaging at laboratory tomography setups
Full-field spectroscopic measurement of the X-ray beam from a multilayer monochromator using a hyperspectral X-ray camera
Multilayer monochromator devices are commonly used at (imaging) beamlines of synchrotron facilities to shape the X-ray beam to relatively small bandwidth and high intensity. However, stripe artefacts are often observed and can deteriorate the image quality. Although the intensity distribution of these artefacts has been described in the literature, their spectral distribution is currently unknown. To assess the spatio-spectral properties of the monochromated X-ray beam, the direct beam has been measured for the first time using a hyperspectral X-ray detector. The results show a large number of spectral features with different spatial distributions for a [Ru, B4C] strip monochromator, associated primarily with the higher-order harmonics of the undulator and monochromator. It is found that their relative contributions are sufficiently low to avoid an influence on the imaging data. The [V, B4C] strip suppresses these high-order harmonics even more than the former, yet at the cost of reduced efficiency
Spectroscopic imaging with single acquisition ptychography and a hyperspectral detector
We present a new method of single acquisition spectroscopic imaging with high spatial resolution. The technique is based on the combination of polychromatic synchrotron radiation and ptychographic imaging with a recently developed energy discriminating detector. We demonstrate the feasibility with a Ni-Cu test sample recorded at I13-1 of the Diamond Light Source, UK. The two elements can be clearly distinguished and the Ni absorption edge is identified. The results prove the feasibility of obtaining high-resolution structural and chemical images within a single acquisition using a polychromatic X-ray beam. The capability of resolving the absorption edge applies to a wide range of research areas, such as magnetic domains imaging and element specific investigations in biological, materials, and earth sciences. The method utilises the full available radiation spectrum and is therefore well suited for broadband radiation sources
X-Ray ptychography with a laboratory source
X-ray ptychography has revolutionized nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. An experiment was conducted with a liquid metal jet x-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 mu m to produce a ptychographic phase image of a Siemens star test pattern with a submicron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide
In-situ high resolution dynamic X-ray microtomographic imaging of olive oil removal in kitchen sponges by squeezing and rinsing
Recent advances in high resolution X-ray tomography (mu CT) technology have enabled in-situ dynamic mu CT imaging (4D-mu CT) of time-dependent processes inside 3D structures, non-destructively and non-invasively. This paper illustrates the application of 4D-mu CT for visualizing the removal of fatty liquids from kitchen sponges made of polyurethane after rinsing (absorption), squeezing (desorption) and cleaning (adding detergents). For the first time, time-dependent imaging of this type of system was established with sufficiently large contrast gradient between water (with/without detergent) and olive oil (model fat) by the application of suitable fat-sensitive X-ray contrast agents. Thus, contrasted olive oil filled sponges were rinsed and squeezed in a unique laboratory loading device with a fluid flow channel designed to fit inside a rotating gantry-based X-ray mu CT system. Results suggest the use of brominated vegetable oil as a preferred contrast agent over magnetite powder for enhancing the attenuation coefficient of olive oil in a multi fluid filled kitchen sponge. The contrast agent (brominated vegetable oil) and olive oil were mixed and subsequently added on to the sponge. There was no disintegration seen in the mixture of contrast agent and olive oil during the cleaning process by detergents. The application of contrast agents also helped in accurately tracking the movement and volume changes of soils in compressed open cell structures. With the in house-built cleaning device, it was quantified that almost 99% of cleaning was possible for contrasted olive oil (brominated vegetable oil with olive oil) dispersed in the sponge. This novel approach allowed for realistic mimicking of the cleaning process and provided closer evaluation of the effectiveness of cleaning by detergents to minimize bacterial growth
3D Correlative Imaging of Lithium Ion Concentration in a Vertically Oriented Electrode Microstructure with a Density Gradient
The performance of Li+ ion batteries (LIBs) is hindered by steep Li+ ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li+ ion concentration gradient problem is exacerbated. Most understanding of Li+ ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li. There are few experimental methods to visualize Li+ ion concentration distribution of the electrode within a battery of typical configurations, for example, coin cells with stainless steel casing. Here, for the first time, an interrupted in situ correlative imaging technique is developed, combining novel, full-field X-ray Compton scattering imaging with X-ray computed tomography that allows 3D pixel-by-pixel mapping of both Li+ stoichiometry and electrode microstructure of a LiNi0.8 Mn0.1 Co0.1 O2 cathode to correlate the chemical and physical properties of the electrode inside a working coin cell battery. An electrode microstructure containing vertically oriented pore arrays and a density gradient is fabricated. It is shown how the designed electrode microstructure improves Li+ ion diffusivity, homogenizes Li+ ion concentration through the ultra-thick electrode (1 mm), and improves utilization of electrode active materials
Efficacy and safety of upadacitinib in a randomized trial of patients with Crohn’s disease
Background & Aims: We evaluated the efficacy and safety of upadacitinib, an oral selective Janus kinase 1 inhibitor, in a randomized trial of patients with Crohn's disease (CD). Methods: We performed a double-blind, phase 2 trial in adults with moderate to severe CD and inadequate response or intolerance to immunosuppressants or tumor necrosis factor antagonists. Patients were randomly assigned (1:1:1:1:1:1) to groups given placebo; or 3 mg, 6 mg, 12 mg, or 24 mg upadacitinib twice daily; or 24 mg upadacitinib once daily and were evaluated by ileocolonoscopy at weeks 12 or 16 of the induction period. Patients who completed week 16 were re-randomized to a 36-week period of maintenance therapy with upadacitinib. The primary endpoints were clinical remission at week 16 and endoscopic remission at week 12 or 16 using the multiple comparison procedure and modeling and the Cochran-Mantel-Haenszel test, with a 2-sided level of 10%. Results: Among the 220 patients in the study, clinical remission was achieved by 13% of patients receiving 3 mg upadacitinib, 27% of patients receiving 6 mg upadacitinib (P < .1 vs placebo), 11% of patients receiving 12 mg upadacitinib, and 22% of patients receiving 24 mg upadacitinib twice daily, and by 14% of patients receiving 24 mg upadacitinib once daily, vs 11% of patients receiving placebo. Endoscopic remission was achieved by 10% (P < .1 vs placebo), 8%, 8% (P < .1 vs placebo), 22% (P < .01 vs placebo), and 14% (P < .05 vs placebo) of patients receiving upadacitinib, respectively, vs none of the patients receiving placebo. Endoscopic but not clinical remission increased with dose during the induction period. Efficacy was maintained for most endpoints through week 52. During the induction period, patients in the upadacitinib groups had higher incidences of infections and serious infections vs placebo. Patients in the twice-daily 12 mg and 24 mg upadacitinib groups had significant increases in total, high-density lipoprotein, and low-density lipoprotein cholesterol levels compared with patients in the placebo group. Conclusions: In a phase 2 trial of patients with CD, upadacitinib induced endoscopic remission in a significant proportion of patients compared with placebo. Upadacitinib's benefit/risk profile supports further development for treatment of CD. (Clinicaltrials.gov, Number: NCT02365649