6 research outputs found

    Gnathostomiasis: A rare case of cutaneous creeping eruptions

    No full text
    A 21-year-old vegetarian lady presenting with migratory erythema and pain in her right hand subsequently developed a blister on the palm. A worm-like structure came out of the wound and was identified as Gnathostoma spp. adult male worm. It is a very rare cause of creeping eruptions and so far only one case of cutaneous gnathostomiasis caused by a larva has been reported from India. This is the first case of cutaneous gnathostomiasis due to an adult Gnathostoma spp. in India

    Device-Associated Infection Rates in 20 Cities of India, Data Summary for 2004–2013: Findings of the International Nosocomial Infection Control Consortium

    No full text
    To report the International Nosocomial Infection Control Consortium surveillance data from 40 hospitals (20 cities) in India 2004-2013. Surveillance using US National Healthcare Safety Network's criteria and definitions, and International Nosocomial Infection Control Consortium methodology. We collected data from 236,700 ICU patients for 970,713 bed-days Pooled device-associated healthcare-associated infection rates for adult and pediatric ICUs were 5.1 central line-associated bloodstream infections (CLABSIs)/1,000 central line-days, 9.4 cases of ventilator-associated pneumonia (VAPs)/1,000 mechanical ventilator-days, and 2.1 catheter-associated urinary tract infections/1,000 urinary catheter-days In neonatal ICUs (NICUs) pooled rates were 36.2 CLABSIs/1,000 central line-days and 1.9 VAPs/1,000 mechanical ventilator-days Extra length of stay in adult and pediatric ICUs was 9.5 for CLABSI, 9.1 for VAP, and 10.0 for catheter-associated urinary tract infections. Extra length of stay in NICUs was 14.7 for CLABSI and 38.7 for VAP Crude extra mortality was 16.3% for CLABSI, 22.7% for VAP, and 6.6% for catheter-associated urinary tract infections in adult and pediatric ICUs, and 1.2% for CLABSI and 8.3% for VAP in NICUs Pooled device use ratios were 0.21 for mechanical ventilator, 0.39 for central line, and 0.53 for urinary catheter in adult and pediatric ICUs; and 0.07 for mechanical ventilator and 0.06 for central line in NICUs. Despite a lower device use ratio in our ICUs, our device-associated healthcare-associated infection rates are higher than National Healthcare Safety Network, but lower than International Nosocomial Infection Control Consortium Report

    Six-year multicenter study on short-term peripheral venous catheters-related bloodstream infection rates in 204 intensive care units of 57 hospitals in 19 cities of India: International Nosocomial Infection Control Consortium (INICC) findings

    No full text

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN
    corecore