    Characterization and Evaluation of the Artemis Camera for Fluorescence-Guided Cancer Surgery

    Get PDF
    Purpose: Near-infrared (NIR) fluorescence imaging can provide the surgeon with real-time visualization of, e.g., tumor margins and lymph nodes. We describe and evaluate the Artemis, a novel, handheld NIR fluorescence camera.Procedures: We evaluated minimal detectable cell numbers (FaDu-luc2, 7D12-IRDye 800CW), preclinical intraoperative detection of sentinel lymph nodes (SLN) using indocyanine green (ICG), and of orthotopic tongue tumors using 7D12-800CW. Results were compared with the Pearl imager. Clinically, three patients with liver metastases were imaged using ICG.Results: Minimum detectable cell counts for Artemis and Pearl were 2 × 105 and 4 × 104 cells, respectively. In vivo, seven SLNs were detected in four mice with both cameras. Orthotopic OSC-19-luc2-cGFP tongue tumors were clearly identifiable, and a minimum FaDu-luc2 tumor size of 1 mm3 could be identified. Six human malignant lesions were identified during three liver surgery procedures.Conclusions: Based on this study, the Artemis system has demonstrated its utility in fluorescence-guided cancer surgery

    Nanobody-targeted photodynamic therapy induces significant tumor regression of trastuzumab-resistant HER2-positive breast cancer, after a single treatment session

    Get PDF
    Rationale: A substantial number of breast cancer patients with an overexpression of the human epidermal growth factor receptor 2 (HER2) have residual disease after neoadjuvant therapy or become resistant to trastuzumab. Photodynamic therapy (PDT) using nanobodies targeted to HER2 is a promising treatment option for these patients. Here we investigate the in vitro and in vivo antitumor efficacy of HER2-targeted nanobody-photosensitizer (PS) conjugate PDT. Methods: Nanobodies targeting HER2 were obtained from phage display selections. Monovalent nanobodies were engineered into a biparatopic construct. The specificity of selected nanobodies was tested in immunofluorescence assays and their affinity was evaluated in binding studies, both performed in a panel of breast cancer cells varying in HER2 expression levels. The selected HER2-targeted nanobodies 1D5 and 1D5-18A12 were conjugated to the photosensitizer IRDye700DX and tested in in vitro PDT assays. Mice bearing orthotopic HCC1954 trastuzumab-resistant tumors with high HER2 expression or MCF-7 tumors with low HER2 expression were intravenously injected with nanobody-PS conjugates. Quantitative fluorescence spectroscopy was performed for the determination of the local pharmacokinetics of the fluorescence conjugates. After nanobody-PS administration, tumors were illuminated to a fluence of 100 J∙cm-2, with a fluence rate of 50 mW∙cm-2, and thereafter tumor growth was measured with a follow-up until 30 days. Results: The selected nanobodies remained functional after conjugation to the PS, binding specifically and with high affinity to HER2-positive cells. Both nanobody-PS conjugates potently and selectively induced cell death of HER2 overexpressing cells, either sensitive or resistant to trastuzumab, with low nanomolar LD50 values. In vivo, quantitative fluorescence spectroscopy showed specific accumulation of nanobody-PS conjugates in HCC1954 tumors and indicated 2 h post injection as the most suitable time point to apply light. Nanobody-targeted PDT with 1D5-PS and 1D5-18A12-PS induced significant tumor regression of trastuzumab-resistant high HER2 expressing tumors, whereas in low HER2 expressing tumors only a slight growth delay was observed. Conclusion: Nanobody-PS conjugates accumulated selectively in vivo and their fluorescence could be detected through optical imaging. Upon illumination, they selectively induced significant tumor regression of HER2 overexpressing tumors with a single treatment session. Nanobody-targeted PDT is therefore suggested as a new additional treatment for HER2-positive breast cancer, particularly of interest for trastuzumab-resistant HER2-positive breast cancer. Further studies are now needed to assess the value of this approach in c

    Efficacy and feasibility of stereotactic radiotherapy after folfirinox in patients with locally advanced pancreatic cancer (LAPC-1 trial)

    Get PDF
    Background: We conducted a multicentre phase II trial to investigate feasibility and antitumor activity of sequential FOLFIRINOX and Stereotactic Body Radiotherapy (SBRT) in patients with locally advanced pancreatic cancer (LAPC), (LAPC-1 trial). Methods: Patients with biopsy-proven LAPC treated in four hospitals in the Netherlands between December 2014 and June 2017. Patients received 8 cycles of FOLFIRINOX followed by SBRT (5 fractions/8 Gy) if no tumour progression after the FOLFIRINOX treatment was observed. Primary outcome was 1-year overall survival (OS). Secondary outcomes were median OS, 1-year progression-free survival (PFS), treatment-related toxicity, and resection rate. The study is registered with ClinicalTrials.gov, NCT02292745, and is completed. Findings: Fifty patients were included. Nineteen (38%) patients did not receive all 8 cycles of FOLFIRINOX, due to toxicity (n = 12), disease progression (n = 6), or patients’ preference (n = 1). Thirty-nine (78%) patients received the SBRT treatment. The 1-year OS and PFS were 64% (95% CI: 50%-76%) and 3

    Selection of optimal molecular targets for tumor-specific imaging in pancreatic ductal adenocarcinoma

    Get PDF
    Discrimination of pancreatic ductal adenocarcinoma (PDAC) from chronic pancreatitis (CP) or peritumoral inflammation is challenging, both at preoperative imaging and during surgery, but it is crucial for proper therapy selection. Tumor-specific molecular imaging aims to enhance this discrimination and to help select and stratify patients for resection. We evaluated various biomarkers for the specific identification of PDAC and associated lymph node metastases. Using immunohistochemistry (IHC), expression levels and patterns were investigated of integrin avβ6, carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5), Cathepsin E (Cath E), epidermal growth factor receptor (EGFR), hepatocyte growth factor receptor (c-MET), thymocyte differentiation antigen 1 (Thy1), and urokinase-type plasminogen activator receptor (uPAR). In a first cohort, multiple types of pancreatic tissue were evaluated (n=62); normal pancreatic tissue (n=8), CP (n=7), PDAC (n=9), tumor associated lymph nodes (n=32), and PDAC after neoadjuvant radiochemotherapy (n=6). In a second cohort, tissues were investigated (n=55) with IHC and immunofluorescence (IF) for concordance of biomarker expression in all tissue types, obtained from an individual patient. Integrin avβ6 and CEACAM5 showed significantly higher expression levels in PDAC versus normal pancreatic tissue (P=0.001 and P < 0.001, respectively) and CP (P=0.003 and P < 0.001, respectively). Avβ6 and CEACAM5 expression identified tumor-positive lymph nodes correctly in 84% and 68%, respectively, and in 100% of tumor-negative nodes for both biomarkers. In conclusion, avβ6 and CEACAM5 are excellent biomarkers to differentiate PDAC from surrounding tissue and to identify lymph node metastases. Individually or combined, these biomarkers are promising targets for tumor-specific molecular imaging of PDAC

    Near-infrared fluorescence imaging compared to standard sentinel lymph node detection with blue dye in patients with vulvar cancer – a randomized controlled trial

    Get PDF
    Objective. The aim of this study was to assess the superiority of ICG-99mTc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients compared to standard SLN detection using 99mTc-nanocolloid with blue dye. Methods. In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99mTc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications. Results. Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99mTc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041). Conclusions. Intraoperative visual detection of SLNs in patients with VSCC using ICG-99mTc-nanocolloid was superior compared to 99mTc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualizatio

    Optical image-guided cancer surgery: Challenges and limitations

    No full text
    Optical image-guided cancer surgery is a promising technique to adequately determine tumor margins by tumor-specific targeting, potentially resulting in complete resection of tumor tissue with improved survival. However, identification of the photons coming from the fluorescent contrast agent is complicated by autofluorescence, optical tissue properties, and accurate fluorescent targeting agents and imaging systems. All these factors have an important influence on the image that is presented to the surgeon. Considering the clinical consequences at stake, it is a prerequisite to answer the questions that are essential for the surgeon. What is optical image-guided surgery and how can it improve patient care? What should the oncologic surgeon know about the fundamental principles of optical imaging to understand which conclusions can be drawn from the images? And how do the limitations influence clinical decision making? This article discusses these questions and provides a clear overview of the basic principles and practical applications. Although there are limitations to the intrinsic capacity of the technique, when practical and technical surgical possibilities are considered, optical imaging can be a very powerful intraoperative tool in guiding the future oncologic surgeon toward radical resection and optimal clinical results

    Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance

    No full text
    Background: Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver. Methods: Patients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard of care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered 1 day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard. Results: Twenty-two patients suspected of having hepatocellular carcinoma (n = 4), cholangiocarcinoma (n = 2) or liver metastases from colorectal carcinoma (n = 12), uveal melanoma (n = 2), and breast cancer (n = 2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80 % (CT), 84 % (MRI), 62 % (inspection), 86 % (LUS), and 92 % (FI), respectively. Three metastases (12 %) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100 % sensitivity). Conclusion: This study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance

    Successful translation of fluorescence navigation during oncologic surgery: A consensus report

    No full text
    Navigation with fluorescence guidance has emerged in the last decade as a promising strategy to improve the efficacy of oncologic surgery. To achieve routine clinical use, the onus is on the surgical community to objectively assess the value of this technique. This assessment may facilitate both Food and Drug Administration approval of new optical imaging agents and reimbursement for the imaging procedures. It is critical to characterize fluorescence-guided procedural benefits over existing practices and to elucidate both the costs and the safety risks. This report is the result of a meeting of the International Society of Image Guided Surgery (www.isigs.org) on February 6, 2015, in Miami, Florida, and reflects a consensus of the participants' opinions. Our objective was to critically evaluate the imaging platform technology and optical imaging agents and to make recommendations for successful clinical trial development of this highly promising approach in oncologic surgery