18 research outputs found
Severe Aortic Stenosis and Myocardial Function: Diagnostic and Prognostic Usefulness of Ultrasonic Integrated Backscatter Analysis
Background— The aim of this study was to assess the myocardial reflectivity pattern in severe aortic valve stenosis through the use of integrated backscatter (IBS) analysis. Patients with aortic stenosis (AS) were carefully selected in the Department of Cardiology.
Methods and Results— Thirty-five subjects (AS: valve orifice ≤1 cm2; 12 female; mean age, 71.8±6.2 years) and 25 healthy subjects were studied. All subjects of the study had conventional 2D-Doppler echocardiography and IBS. Backscatter signal was sampled at the septum and posterior wall levels. Patients with AS were divided into 2 groups: 16 patients with initial signs of congestive heart failure and a depressed left ventricular systolic function (DSF) (ejection fraction [EF] range, 35% to 50%) and 19 asymptomatic patients with normal left ventricular systolic function (NSF) (EF >50%). Myocardial echo intensity (pericardium related) was significantly higher at the septum and posterior wall levels in DSF than in NSF and in control subjects. IBS variation, as an expression of variation of the signal, appeared to be significantly lower in AS with DSF than in NSF and in control subjects, at both the septum and posterior wall levels. Patients with DSF underwent aortic valve replacement, and, during surgical intervention, a septal myocardial biopsy was made for evaluation of myocardium/fibrosis ratio. Abnormally increased echo intensity was detected in left ventricular pressure overload by severe aortic stenosis and correlated with increase of myocardial collagen content (operating biopsy).
Conclusions— One year after aortic valve replacement, we observed a significant reduction of left ventricular mass, and, only if pericardial indexed IBS value (reduction of interstitial fibrosis) decreased, it was possible to observe an improvement of EF and of IBS variation
Mitral valve annuloplasty for degenerative disease: assessment of four different techniques
mitral valve repair techniques and follow u
Dysfunction of a 21-mm aortic bioprosthesis treated with percutaneous implantation of a CoreValve prosthesis
Percutaneous aortic valve replacement is an emerging alternative for high surgical risk patients with native aortic valve stenosis. We describe for the first time a valve-in-valve procedure with a CoreValve prosthesis for the treatment of a severely stenotic degenerated aortic bioprosthesis. © 2013 Italian Federation of Cardiology
Valve-related complications in elderly patients with biological and mechanical aortic valves
BACKGROUND: Controversy still exists about the choice of aortic prosthesis in elderly patients. This study investigates valve- and anticoagulant-related morbidity and mortality in elderly patients after aortic valve replacement (AVR) with a biologic (BP) or mechanical prosthesis (MP). METHODS: Between 1981 and 1995, 355 consecutive patients aged 70 years or older (mean, 74+/-4 years; range, 70 to 87 years) underwent isolated AVR. There were 222 (63%) replacements with an MP and 133 (37%) with a BP. Mean follow-up was 3.7+/-2.8 years (range, 3 months to 15 years), with a total follow-up of 1,214 patient-years. RESULTS: Hospital mortality was 7.6% (27 of 355), decreasing to 4.6% in the last 3 years. There were 55 late deaths, 33 in patients with MP and 22 in those with BP. At 10 years there was no significant difference between MP and BP recipients in the actuarial estimates of survival (51%+/-8% versus 33%+/-13%), freedom from valve-related death (82%+/-7% versus 72%+/-12%), and freedom from thromboembolism (84%+/-7% versus 94%+/-3%). In contrast, 10-year freedom from anticoagulant-related hemorrhages was 74%+/-8% for MP and 99%+/-1% for BP (p = 0.02). Only 1 structural deterioration occurred, in a patient with BP. CONCLUSIONS: Satisfactory early results can be obtained in elderly patients after AVR with both MP and BP. The comparable low late survival in the two groups was predominantly influenced by non-valve-related deaths. A higher incidence of anticoagulant-related hemorrhages limits the use of MP in elderly patients. Thus, in this population, BP should be preferred not just on the basis of their expected longer durability, but mainly to avoid the risk of anticoagulant-related hemorrhages