844 research outputs found

    Dosimetric characterization of a synthetic single crystal diamond detector in a clinical 62 MeV ocular therapy proton beam

    Get PDF
    A synthetic single crystal diamond based Schottky photodiode was tested at INFN-LNS on the proton beam line (62 MeV) dedicated to the radiation treatment of ocular disease. The diamond detector response was studied in terms of pre-irradiation dose, linearity with dose and dose rate, and angular dependence. Depth dose curves were measured for the 62 MeV pristine proton beam and for three unmodulated range-shifted proton beams; furthermore, the spread-out Bragg peak was measured for a modulated therapeutic proton beam. Beam parameters, recommended by the ICRU report 78, were evaluated to analyze depth-dose curves from diamond detector. Measured dose distributions were compared with the corresponding dose distributions acquired with reference plane-parallel ionization chambers. Field size dependence of the output factor (dose per monitor unit) in a therapeutic modulated proton beam was measured with the diamond detector over the range of ocular proton therapy collimator diameters (5-30 mm). Output factors measured with the diamond detector were compared to the ones by a Markus ionization chamber, a Scanditronix Hi-p Si stereotactic diode and a radiochromic EBT2 film. Signal stability within 0.5% was demonstrated for the diamond detector with no need of any pre-irradiation dose. Dose and dose rate dependence of the diamond response was measured: deviations from linearity resulted to be within ±0.5% over the investigated ranges of 0.5-40.0 Gy and 0.3-30.0 Gy/min respectively. Output factors from diamond detector measured with the smallest collimator (5 mm in diameter) showed a maximum deviation of about 3% with respect to the high resolution radiochromic EBT2 film. Depth-dose curves measured by diamond for unmodulated and modulated beams were in good agreement with those from the reference plane-parallel Markus chamber, with relative differences lower than ±1% in peak-to-plateau ratios, well within experimental uncertainties. A 2.5% variation in diamond detector response was observed in angular dependence measurements carried-out by varying the proton beam incidence angle in the polar direction. The dosimetric characterization of the tested synthetic single crystal diamond detector clearly indicates its suitability for relative dosimetry in ocular therapy proton beams, with no need of any correction factors accounting for dose rate and linear energy transfer dependence

    A diamond detector based dosimetric system for instantaneous dose rate measurements in FLASH electron beams

    Get PDF
    Objective. A reliable determination of the instantaneous dose rate (I-DR) delivered in FLASH radiotherapy treatments is believed to be crucial to assess the so-called FLASH effect in preclinical and biological studies. At present, no detectors nor real-time procedures are available to do that in ultra high dose rate (UH-DR) electron beams, typically consisting of ÎŒs pulses characterized by I-DRs of the order of MGy/s. A dosimetric system is proposed possibly overcoming the above reported limitation, based on the recently developed flashDiamond (fD) detector (model 60025, PTW-Freiburg, Germany). Approach. A dosimetric system is proposed, based on a flashDiamond detector prototype, properly modified and adapted for very fast signal transmission. It was used in combination with a fast transimpedance amplifier and a digital oscilloscope to record the temporal traces of the pulses delivered by an ElectronFlash linac (SIT S.p.A., Italy). The proposed dosimetric systems was investigated in terms of the temporal characteristics of its response and the capability to measure the absolute delivered dose and instantaneous dose rate (I-DR). A ‘standard’ flashDiamond was also investigated and its response compared with the one of the specifically designed prototype. Main results. Temporal traces recorded in several UH-DR irradiation conditions showed very good signal to noise ratios and rise and decay times of the order of a few tens ns, faster than the ones obtained by the current transformer embedded in the linac head. By analyzing such signals, a calibration coefficient was derived for the fD prototype and found to be in agreement within 1% with the one obtained under reference 60Co irradiation. I-DRs as high as about 2 MGy s−1 were detected without any undesired saturation effect. Absolute dose per pulse values extracted by integrating the I-DR signals were found to be linear up to at least 7.13 Gy and in very good agreement with the ones obtained by connecting the fD to a UNIDOS electrometer (PTW-Freiburg, Germany). A good short term reproducibility of the linac output was observed, characterized by a pulse-to-pulse variation coefficient of 0.9%. Negligible differences were observed when replacing the fD prototype with a standard one, with the only exception of a somewhat slower response time for the latter detector type. Significance. The proposed fD-based system was demonstrated to be a suitable tool for a thorough characterization of UH-DR beams, providing accurate and reliable time resolved I-DR measurements from which absolute dose values can be straightforwardly derived

    Resonant third harmonic generation of KrF laser in Ar gas

    Get PDF
    Investigations of emission of harmonics from argon gas jet irradiated by 700 fs, 5 mJ pulses from a KrF laser are presented. Harmonics conversion was optimized by varying the experimental geometry and the nozzle size. For the collection of the harmonic radiation silicon and solar-blind diamond semiconductor detectors equipped with charge preamplifiers were applied. The possibility of using a single-crystal CVD diamond detector for separate measurement of the 3rd harmonic in the presence of a strong pumping radiation was explored. Our experiments show that the earlier suggested 0.7% conversion efficiency can really be obtained, but only in the case when phase matching is optimized with an elongated gas target length corresponding to the length of coherence

    Accurate spectra for high energy ions by advanced time-of-flight diamond-detector schemes in experiments with high energy and intensity lasers

    Get PDF
    Time-Of-Flight (TOF) methods are very effective to detect particles accelerated in laser-plasma interactions, but they show significant limitations when used in experiments with high energy and intensity lasers, where both high-energy ions and remarkable levels of ElectroMagnetic Pulses (EMPs) in the radiofrequency-microwave range are generated. Here we describe a novel advanced diagnostic method for the characterization of protons accelerated by intense matter interactions with high-energy and high-intensity ultra-short laser pulses up to the femtosecond and even future attosecond range. The method employs a stacked diamond detector structure and the TOF technique, featuring high sensitivity, high resolution, high radiation hardness and high signal-to-noise ratio in environments heavily affected by remarkable EMP fields. A detailed study on the use, the optimization and the properties of a single module of the stack is here described for an experiment where a fast diamond detector is employed in an highly EMP-polluted environment. Accurate calibrated spectra of accelerated protons are presented from an experiment with the femtosecond Flame laser (beyond 100 TW power and ~ 1019 W/cm2 intensity) interacting with thin foil targets. The results can be readily applied to the case of complex stack configurations and to more general experimental conditions

    Accurate spectra for high energy ions by advanced time-of-flight diamond-detector schemes in experiments with high energy and intensity lasers

    Get PDF
    Time-Of-Flight (TOF) methods are very effective to detect particles accelerated in laser-plasma interactions, but they shows significant limitations when used in experiments with high energy and intensity lasers, where both high-energy ions and remarkable levels of ElectroMagnetic Pulses (EMPs) in the radiofrequency-microwave range are generated. Here we describe a novel advanced diagnostic method for the characterization of protons accelerated by intense matter interactions with high-energy and high-intensity ultra-short laser pulses up to the femtosecond and even future attosecond range. The method employs a stacked diamond detector structure and the TOF technique, featuring high sensitivity, high resolution, high radiation hardness and high signal-to-noise ratio in environments heavily affected by remarkable EMP fields. A detailed study on the use, the optimization and the properties of a single module of the stack is here also described for an experiment where a fast diamond detector is employed in an highly EMP-polluted environment. Accurate calibrated spectra of accelerated protons are presented from an experiment with the femtosecond Flame laser (beyond 100 TW power and ~101910^{19} W/cm2^2 intensity) interacting with thin foil targets. The results that can be readily applied to the case of complex stack configurations and to more general experimental conditions.Comment: 19 pages, 8 figure

    Harnessing difference: a capability-based framework for stakeholder engagement in environmental innovation

    Get PDF
    Innovation for environmental sustainability requires firms to engage with external stakeholders to access expertise, solve complex problems, and gain social legitimacy. In this open innovation context, stakeholder engagement is construed as a dynamic capability that can harness differences between external stakeholders to augment their respective resource bases. An integrative systematic review of evidence from 88 scientific articles finds that engaging stakeholders in environmental innovation requires three distinct levels of capability: specific operational capabilities; first-order dynamic capabilities to manage the engagement (engagement management capabilities); and second-order dynamic capabilities to make use of contrasting ways of seeing the world to reframe problems, combine competencies in new ways, and co-create innovative solutions (value framing), and to learn from stakeholder engagement activities (systematized learning). These findings enhance understanding of how firms can effectively incorporate stakeholder perspectives for environmental innovation, and provide an organizing framework for further research into open innovation and co-creation more broadly. Wider contributions to the dynamic capabilities literature are to (i) offer a departure point for further research into the relationship between first-order and second-order dynamic capabilities, (ii) suggest that institutional theory can help explain the dynamic capability of value framing, (iii) build on evidence that inter-institutional learning is contingent on not only the similarity but also the differences between organizational value frames, and (iv) suggest that operating capabilities impact the effectiveness of dynamic capabilities, rather than only the other way around, as is usually assumed. A methodological contribution is made through the application of quality assessment criteria scores and intercoder reliability statistics to the selection of articles included in the systematic review

    Harnessing difference: a capability-based framework for stakeholder engagement in environmental innovation

    Get PDF
    Innovation for environmental sustainability requires firms to engage with external stakeholders to access expertise, solve complex problems, and gain social legitimacy. In this open innovation context, stakeholder engagement is construed as a dynamic capability that can harness differences between external stakeholders to augment their respective resource bases. An integrative systematic review of evidence from 88 scientific articles finds that engaging stakeholders in environmental innovation requires three distinct levels of capability: specific operational capabilities; first-order dynamic capabilities to manage the engagement (engagement management capabilities); and second-order dynamic capabilities to make use of contrasting ways of seeing the world to reframe problems, combine competencies in new ways, and co-create innovative solutions (value framing), and to learn from stakeholder engagement activities (systematized learning). These findings enhance understanding of how firms can effectively incorporate stakeholder perspectives for environmental innovation, and provide an organizing framework for further research into open innovation and co-creation more broadly. Wider contributions to the dynamic capabilities literature are to (i) offer a departure point for further research into the relationship between first-order and second-order dynamic capabilities, (ii) suggest that institutional theory can help explain the dynamic capability of value framing, (iii) build on evidence that inter-institutional learning is contingent on not only the similarity but also the differences between organizational value frames, and (iv) suggest that operating capabilities impact the effectiveness of dynamic capabilities, rather than only the other way around, as is usually assumed. A methodological contribution is made through the application of quality assessment criteria scores and intercoder reliability statistics to the selection of articles included in the systematic review

    Time-of-flight methodologies with large-area diamond detectors for ion characterization in laser-driven experiments

    Get PDF
    The time-of-flight technique coupled with semiconductor detectors is a powerful instrument to provide real-time characterization of ions accelerated because of laser-matter interactions. Nevertheless, the presence of strong electromagnetic pulses (EMPs) generated during the interactions can severely hinder its employment. For this reason, the diagnostic system must be designed to have high EMP shielding. Here we present a new advanced prototype of detector, developed at ENEA-Centro Ricerche Frascati (Italy), with a large-area (15 mm × 15 mm) polycrystalline diamond sensor having 150 ÎŒm thickness. The tailored detector design and testing ensure high sensitivity and, thanks to the fast temporal response, high-energy resolution of the reconstructed ion spectrum. The detector was offline calibrated and then successfully tested during an experimental campaign carried out at the PHELIX laser facility (100 J, fs, W/cm2) at GSI (Germany). The high rejection to EMP fields was demonstrated and suitable calibrated spectra of the accelerated protons were obtained
    • 

    corecore