10 research outputs found

    Dopplerfluxometria das artérias renais: valores normais das velocidades sistólica e diastólica e do índice resistivo nas artérias renais principais Renal arteries Dopplerfluxometry: normal systolic and diastolic flow velocities and resistive index values in the main renal arteries

    No full text
    Dopplerfluxometry of renal arteries has been used to estimate renal perfusion in humans. The aim of this study was to use Dopplerfluxometry technique to calculate the resistive index of main renal arteries in dogs, measuring their systolic and diastolic blood flow velocities. Twenty (10 males, 10 females), adult mongrel dogs, were used in this study. The dogs were submitted to Doppler sonographic evaluation of left and right main renal arteries. The systolic and diastolic blood flow velocities, expressed (in centimeters per second) as mean and standard deviation were 79.96± 8.82 and 28.86± 5.11 in the right main renal artery and 80.22± 6.99 and 29.62± 4.14 in the left main renal artery. The value of resistive index expressed as mean ± standard deviation was 0.64± 0.04 for the right main renal artery and 0.63± 0.028 in the left main renal artery

    Avaliação e comparação entre métodos de mensuração de pressão arterial sistólica em gatos hígidos anestesiados

    No full text
    Foram avaliados e comparados, para fins de validação, dois diferentes métodos de mensuração de pressão arterial sistólica (PAS), não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro), em 12 gatos hígidos anestesiados de idade variando entre sete meses e dois anos. Em cada animal, procedeu-se à mensuração simultânea da pressão não invasiva e da invasiva. O método oscilométrico foi comparado, por meio de sete medidas consecutivas, com intervalo de 30 segundos entre elas, com o método invasivo, e, logo em seguida, o método Doppler foi comparado ao método invasivo da mesma maneira. Concluiu-se que o método oscilométrico é estatisticamente igual ao método invasivo, enquanto o Doppler difere de ambos. Entretanto, pela forte correlação positiva entre os métodos Doppler e invasivo, foi possível criar um fator de correção (equação de regressão linear) para se determinar o valor da pressão invasiva, a partir do valor obtido pelo método Doppler. Para obtenção de valores mais fidedignos, recomenda-se a utilização desse fator de correção quando o método Doppler for utilizado para mensuração de PAS em gatos anestesiados

    Avaliação e comparação entre métodos de mensuração de pressão arterial sistólica em gatos hígidos conscientes

    No full text
    RESUMO Após validação de dois diferentes métodos de mensuração de pressão arterial sistólica (PAS) não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro) em 12 gatos hígidos anestesiados de mesma faixa etária, os métodos não invasivos foram avaliados e comparados em 24 gatos hígidos e conscientes, divididos em quatro grupos de idade. Em cada animal, procedeu-se à mensuração da pressão pelos métodos Doppler e oscilométrico. O método oscilométrico foi o primeiro a ser realizado, e, logo em seguida, o método Doppler. Os valores considerados foram obtidos das médias de sete medidas consecutivas para cada método, com intervalo de 30 segundos entre elas. A primeira medida e as medidas discrepantes (variação ˃ 20% PAS), obtidas com sinais óbvios de estresse e/ou com movimentação do animal, foram descartadas. Os métodos de mensuração oscilométrico e Doppler, embora tenham apresentado médias estatisticamente diferentes em todos os grupos, quando comparados em cada grupo, apresentaram uma correlação significativa, alta e positiva. Ou seja, sempre que for obtido um valor elevado por um método, o mesmo fato ocorrerá com o outro método e vice-versa. Clinicamente, a diferença observada não é relevante, uma vez que a diferença média dos valores obtida pelos dois métodos, em cada grupo, foi menor que 1,1%

    Ureter ectópico extramural em um cão Labrador Retriever: relato de caso

    No full text
    RESUMO A ectopia ureteral é uma enfermidade congênita que se caracteriza quando um ou ambos os ureteres apresentam-se inseridos fora do seu local anatômico, com a inserção ocorrendo no útero, no colo da bexiga, na uretra ou na vagina, devido a uma diferenciação anormal dos ductos mesonéfricos e metanéfricos. Nos machos, a inserção pode ocorrer também nos ductos deferentes e na próstata. A incontinência urinária é o sinal clínico mais comumente associado ao ureter ectópico. O presente relato descreve um caso de ureter ectópico extramural unilateral, em um cão da raça Labrador Retriever de sete anos de idade, corrigido cirurgicamente, e mostra a importância dos exames radiográfico contrastado e ultrassonografia

    Uso de cetoanálogo na terapia da insuficiência renal canina Use of keto analogues in therapy of the renal failure in dogs

    No full text
    <abstract language="eng">The efficacy of keto acids and essential amino acids on a two-year-old female dog, Labrador, suffering from Leishmaniasis and acute renal failure was evaluated by clinical and laboratorial analyses based on urea and creatinine dosages. An improving in the animal general condition and an increasing in the appetite, activity and weight gain, were observed and favorably contributed to the treatment of the primary disease. Ketoanalogueswere oraly administered during 76 days and the levels of urea and creatinine remained within acceptable limits, even after this period of time. Ketoanaloguescontributed positively for the treatment of acute renal failure and appears to be an important alternative for the leishmaniasis treatment

    Acesso vascular para hemodiálise com cateter temporário de duplo lúmen em cães com insuficiência renal aguda Hemodialysis vascular access with temporary double-lumen catheter in dogs with acute renal failure

    No full text
    A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA), enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD), com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%), devido à obstrução do lúmen do cateter em seis sessões (5,8%) ou por saída acidental do mesmo em uma sessão (1,0%). Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.<br>Hemodialysis is a therapeutic procedure that can sustain the patient's life in acute renal failure (ARF), during the renal function recover. To perform hemodialysis (HD), an extracorporeal circulation is established to blood filtration, imposing the need of a viable and efficient vascular access. The aim of this study was to evaluate the effectiveness and complications of the HD vascular access with temporary double-lumen catheter inserted into the external jugular vein. Ten mongrel dogs with ARF, induced by gentamicin administration, were submitted to daily hemodialysis for one hour, until renal function recover or death. A total of 104 HD sessions were performed. Catheter replacement was accomplished in seven sessions (6.7%), due to catheter lumen mechanical obstruction in six sessions (5.8%) or accidental catheter output in one session (1.0%). No catheter migration, infection, bleeding or haematoma around the catheter insertion site was found. Effective blood flow rates were observed in 90.4% HD sessions. In conclusion, the vascular access in jugular external vein with temporary double-lumen catheter was valuable, with few complications, and should be indicated to vascular access in extracorporeal circulation to HD in ARF dogs
    corecore