23 research outputs found

    Formation of ITB in the vicinity of rational surfaces in the Uragan-3M torsatron

    No full text
    It was shown that there is the possibility of ITB formation in the vicinity of rational surfaces in a torsatron magnetic configuration. The formation of ITB is accompanied by fast change of plasma poloidal rotation velocity, radial electric field and its shear and the decrease of plasma density fluctuations. After the ITB formation the transition to the improved plasma confinement takes place. The transition stars when electron temperature in the region of rational surfaces is sufficient to satisfy the condition υTe/uei>>2πR0 (here υTe is electron thermal velocity and uei is the frequency of ion – electron collisions, and R0 is the major radius of the torus). Such a regime can be maintained during the whole duration of RF discharge without any disturbances.Показано, що існує можливість формування внутрішнього теплового бар’єру (ВТБ) в плазмі ВЧ розряду в околиці раціональних поверхонь в торсатронній магнітній конфігурації. Формування ВТБ супроводжується бистрими змінами швидкості полоідального обертання плазми, радіального електричного поля и його шира і зменшенням флуктуацій густини плазми поблизу раціональних поверхонь. Після формування ВТБ спостерігається перехід в режим поліпшеного утримання плазми. Час переходу зменшується із збільшенням ВЧ потужності нагріву.Показано, что имеется возможность формирования внутреннего теплового барьера (ВТБ) в плазме ВЧ разряда в окрестности рациональных поверхностей в торсатронной магнитной конфигурации. Формирование ВТБ сопровождается быстрыми изменениями скорости полоидального вращения плазмы, радиального электрического поля и его шира и уменьшением флуктуаций плотности плазмы вблизи рациональных поверхностей. После формирования ВТБ наблюдается переход в режим улучшенного удержания плазмы. Время перехода сокращается с увеличением ВЧ мощности нагрева

    МОДЕЛИРОВАНИЕ ФИКСАЦИИ КОСТНЫХ ФРАГМЕНТОВ АППАРАТОМ ВНЕШНЕЙ ФИКСАЦИИ ПРИ ДВУХСТОРОННИХ РОТАЦИОННО-НЕСТАБИЛЬНЫХ ПОВРЕЖДЕНИЯХ ТАЗА ТИПА В ПО КЛАССИФИКАЦИИ AO/ASIF

    Get PDF
    Objective: to determine the stability of bone fragments fixation with an external fixation device in the simulation of bilateral partly unstable pelvic injuries of B type according to AO/ASIF classification and to identify the role of different fixation elements in the stability of fixation. Material and methods: the study was performed on the finite element model of a system an external fixation device - pelvis developed for a software package MSCNastran. Formation of a fracture of pubic and ischial pelvic bones was accomplished by means of rupture in the finite element network and decrease of elasticity modulus in the ilio-sacral joint on both sides up to 35 mm at the site of a fracture. Loads were carried on top of the body of the first sacral vertebra with a force of 500H.The second area of application of the load was from the bottom-up on the acetabular roof with a force of 250H. In this study the effect of different elements of an external fixation device on the stiffness of bone fragments fixation was evaluated. Symmetrical elements were removed both separately and together. As a result, the stiffness of a system decreased and the displacement at the fracture site increased. Conclusion: in a model of partly stable pelvic injuries accompanied by general rotation instability in the horizontal and sagittal planes to 35 mm, an external fixation device provided high stability of bone fragments (to 3 mm) due to introduction of bone rods in the iliac wings with the obligatory introduction of the rod in the vertical branches of pubic bones and strengthening the anterior lower bar between the subsystems. What is more, installing the anterior upper bar or introduction of bone rods in the bodies of iliac bone are not necessary.Цель исследования: определение стабильности фиксации костных отломков аппаратом внешней фиксации при моделировании двусторонних частично стабильных повреждений таза типа В по классификации AO/ASIF с определением вклада отдельных элементов в стабильность фиксации. Материал и методы. Исследование проводилось на конечно-элементной модели системы аппарат внешней фиксации - таз, разработанной для программного комплекса MSC Nastran. Формирование перелома лонных и седалищных костей таза в модели осуществлялось путем разрыва в конечно-элементной сетке и уменьшением модуля упругости в подвздошно-крестцовом сочленении с обеих сторон до 35 мм на месте формирования перелома. Нагрузки на модель осуществлялись сверху на тело первого крестцового позвонка с силой 500 Н. Вторая область приложения нагрузки - снизу вверх на крышу вертлужной впадины с силой 250 Н. В ходе исследования оценивалось влияние отдельных элементов аппаратов внешней фиксации (АВФ) на жесткость фиксации костных отломков. Симметричные элементы удалялись как по отдельности, так и совместно. В результате происходило уменьшение жесткости АВФ и соответствующее увеличение смещения в месте перелома. Выводы. При моделировании частично стабильных повреждений таза, когда имеет место общая ротационная нестабильность в горизонтальной и сагиттальной плоскостях до 35 мм, АВФ обеспечивают высокую стабильность костных фрагментов (до 3 мм) за счет введения костных стержней в крылья подвздошных костей, с обязательным введением стержня в вертикальные ветви лонных костей и усилением передне-нижней штанги между подсистемами. При этом установка передне-верхней штанги и введение костных стержней в тела подвздошных костей не являются обязательными

    Production of antideuterons by 43 GeV, 52 GeV and 70 GeV protons

    No full text
    The production of antideuterons on aluminium nuclei by 43 GeV, 52 GeV and 70 GeV protons has been measured. © 1969.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore