71 research outputs found

    Comparative analysis of pregnancy development and output after assisted reproductive technologies at different variants of hormonal support (preliminary results)

    Get PDF
    The duration of hormonal support after assisted reproductive technologies (ART) and different used medicines is steel questionable. The analysis of development and pregnancy output of patients with monofetal pregnancy after ART was performed 10 patients received monotherapy (didrogesterone) and 22 patients received several hormonal preparations. There were no significant differences between these two groups of patients in terms of pregnancy output and complications.Вопрос продолжительности гормональной поддержки после применения вспомогательных репродуктивных технологий (ВРТ) и спектра применяемых препаратов остается обсуждаемым в литературе. С целью оценки возможности использования монотерапии проведен анализ течения и исходов беременности 10 пациенток с одноплодной беременностью после ВРТ, получавших в качестве поддержки единственный препарат-дидрогестерон, составивших основную группу, и 22 пациенток, получавших несколько гормональных препаратов, составивших группу сравнения. В результате исследования не выявлено значимых различий между группами в развитии осложнений беременности и ее исходов

    ИССЛЕДОВАНИЕ ПЕРФУЗИИ ПРИ НАРУШЕНИЯХ ЦЕРЕБРАЛЬНОГО КРОВООБРАЩЕНИЯ. ЧАСТЬ II (ЧАСТНАЯ КТ- И МР-СЕМИОТИКА, ПАТТЕРНЫ ПАТОЛОГИЧЕСКИХ ИЗМЕНЕНИЙ). ОБЗОР

    Get PDF
    The second part of a review article devoted to a detailed consideration of the issues of diagnostic semiotics of acute disorders of cerebral circulation using CT and MR perfusion study techniques. We consider the physiological aspects of formation of the basic parameters of tissue perfusion: of cerebral blood Șow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time to peak (TTP) contrast, as well as patterns of pathological changes in these parameters (hypo-, hyper- and aperfusion), developing in various degrees of brain ischemic damage and penumbra areas. It is noted that the improvement of MRI using for tissue classi⠇cation of perfusion-diநusion (PWI/DWI) mismatch has a better chance of primary development due to the fact that it non-radiation exposure and is not connected with the need to introduce a large contrast volume, and with the introduction of non-contrast arterial spin labeled technique (ASL). Variants of events in the dynamics of perfusion as a result of reperfusion therapy. There were discussed the problems limiting the use of perfusion techniques in clinical practice.Вторая часть обзорной статьи посвящена детальному рассмотрению вопросов диагностической семиотики острых нарушений церебрального кровообращения с использованием КТ- и МР-методик перфузионного исследования. Рассмотрены физиологические аспекты формирования основных параметров тканевого кровотока: скорости (CBF), объема кровотока (CBV) и времени транзита (МТТ) и пика (TTP) контрастирования, а также паттерны патологических изменений этих параметров (гипо-, гипер- и аперфузия), развивающиеся в различных по степени ишемического повреждения зонах инфаркта и пенумбры. Отмечается, что совершенствование МРТ с применением для тканевой классификации комплекса перфузионно-диффузионного несоответствия (PWI/DWI mismatch) имеет большие шансы преимущественного развития вследствие того, что лишена лучевой нагрузки и не связана с необходимостью введения большого объема контраста, а с внедрением методики мечения спинов артериальной крови (ASL) – и вовсе без такового. Представлены варианты перфузионных событий в динамике и в результате реперфузионных мероприятий. Обсуждены проблемы, ограничивающие применение перфузионных методик в широкой клинической практике

    Сравнение режущих и коагуляционных свойств волоконных лазеров с длиной волны 1,56 и 1,94 мкм с полупроводниковым лазером 0,98 мкм

    Get PDF
    Aim of the study was to compare the cutting and coagulation properties of 1.56 and 1.94 μm fiber lasers with those of a 0.98 μm semiconductor laser.Materials and methods. A comparative study of the biological effects of 1.56 and 1.94 µm lasers and a 0.98 µm semiconductor laser used in a constant, continuous mode was carried out. The cutting properties of the lasers were evaluated on the chicken muscle tissue samples by the width and depth of the ablation zone formed via a linear laser incision at a speed of 2 mm/s, while the coagulation properties were assessed by the width of the lateral coagulation zone. The zones were measured using a surgical microscope and a calibration slide. For statistical analysis, power values of 3, 5, 7, 9, and 11 W were chosen for each laser wavelength.Results. Analysis of the findings confirmed that laser wavelength had a statistically significant effect on the linear dependence between incision parameters and laser power. It was found that the 1.56 μm fiber laser (water absorption) had a greater coagulation ability but a comparable cutting ability compared with the 0.98 μm laser (hemoglobin absorption). When used in the power mode of 7W or higher, the 1.94 µm laser provided superior cutting performance compared with the 0.98 µm semiconductor laser at the same exposure power. Elevating the power in any of the lasers primarily increased the width of the ablation zone, and to a lesser extent – the crater depth and the width of the lateral coagulation zone. Therefore, in comparison with the 0.98 μm semiconductor laser, higher radiation power in the 1.56 and 1.94 μm lasers mainly influences their cutting properties, expanding the width and depth of the ablation zone, and has a smaller effect on their coagulation ability.Conclusion. The findings of the study showed that the 1.56 and 1.94 μm fiber lasers have better coagulation properties in comparison with the 0.98 μm semiconductor laser. was statistically proven that all incision characteristics (width of the lateral coagulation zone, depth and width of the ablation zone) for the 1.56, 1.94, and 0.98 μm lasers depend on the power of laser radiation. The 1.94 µm laser is superior to the 0.98 µm laser in its cutting properties. Цель – провести сравнительную оценку режущих и коагуляционных свойств волоконных лазеров с длинами волн 1,56 и 1,94 мкм с полупроводниковым лазером 0,98 мкм.Материалы и методы. Проведено сравнительное исследование биологических свойств волоконных лазеров с длиной волны 1,56 и 1,94 мкм с полупроводниковым лазером 0,98 мкм в постоянном непрерывном режиме. Режущие свойства лазеров оценивались на мышечной ткани курицы по ширине и глубине зоны абляции, формируемой в ходе линейного лазерного разреза со скоростью 2 мм/с, коагуляционные – по ширине боковой зоны коагуляции. Измерение зон проводили в условиях микроскопии с помощью калибровочного предметного стекла. Для статистического анализа выбрали значения мощности 3, 5, 7, 9 и 11 Вт для каждой длины волны лазерного излучения.Результаты. Анализ полученных результатов измерений подтвердил статистически значимое влияние длины волны лазерного излучения на характер линейной зависимости параметров лазерного разреза от мощности воздействия. Установлено, что волоконный водопоглощаемый лазер с длиной волны 1,56 мкм обладает большей коагулирующей способностью, но сопоставимой способностью к резке тканей по сравнению с гемоглобинпоглощаемым лазером с длиной волны 0,98 мкм. Лазер с длиной волны 1,94 мкм на мощности 7 Вт и выше превосходит по своим режущим свойствам полупроводниковый лазер 0,98 мкм на той же мощности воздействия. Для всех лазеров прирост мощности излучения в большей степени увеличивает ширину зоны абляции, в меньшей степени – глубину кратера и ширину боковой зоны коагуляции. Таким образом, прирост мощности излучения для лазеров с длиной волны 1,56 и 1,94 мкм преимущественно влияет на режущие свойства, увеличивая ширину и глубину формируемой зоны абляции, в меньшей степени – на его коагуляционные способности в сравнении с полупроводниковым лазером с длиной волны 0,98 мкм.Заключение. По результатам экспериментального исследования обнаружено, что лазеры с длиной волны 1,56 и 1,94 мкм обладают лучшими коагулирующими свойствами в сравнении с полупроводниковым лазером 0,98 мкм. Статистически доказано, что все параметры лазерного разреза (ширины боковой зоны коагуляции, глубины и ширины зоны абляции) для лазеров с длиной волны 1,56; 1,94 и 0,98 мкм зависят от мощности лазерного излучения. Лазер с длиной волны 1,94 мкм превосходит лазер 0,98 мкм по своим режущим свойствам.

    КРИТЕРИИ ДИАГНОСТИКИ НЕГЕМОРРАГИЧЕСКОГО ВЕНОЗНОГО ИНСУЛЬТА МЕТОДАМИ РЕНТГЕНОВСКОЙ МУЛЬТИСПИРАЛЬНОЙ КОМПЬЮТЕРНОЙ (МСКТ) И МАГНИТНО-РЕЗОНАНСНОЙ (МРТ) ТОМОГРАФИИ

    Get PDF
     Purpose. The study was aimed at detecting the signs of focal and perifocal injury in venous strokes and their differences from those in arterial strokes by urgent CT and MRI. Materials and methods. The diagnosis of a venous stroke was verifi ed by neurovisualization (native MSCT, perfusion CT or CT angiography, conventional MRI and MR-angiography) and during autopsy (in case of a fatal outcome). Results. Patients with venous strokes had a hyperdense (by routine CT) stroke-related vessel, compensatory venous distention on the side of the occlusion, early haemorrhagic transformation, the changes localized in the region of the affected vein. Conclusions. The study allowed to detect CT and MRI signs, which can help to differentiate arterial and venous strokes.Цель. Определение признаков фокального и перифокального повреждения при венозном инсульте и их отличие от артериального инсульта по данным ургентной компьютерной и магнитно-резонансной томографий. Материалы и методы. Верификация диагноза венозного инсульта выполнялась методами нейровизуализации (нативная МСКТ, перфузионная КТ или КТ-ангиография, конвенциальная МРТ, МР-ангиография) и при патологоанатомическом исследовании (в случаях летального исхода). Результаты. У пациентов с венозным инсультом выявлялись гиперденсный (при рутинной КТ) симптомсвязанный сосуд, компенсаторное расширение вен на стороне окклюзии, ранняя геморрагическая трансформация, локализация изменений, соответствующая бассейну пораженного дренирующего сосуда. Выводы. Определены КТ и МРТ рентгенологические признаки, позволяющие дифференцировать артериальный и венозный инсульты.

    A model of the deformation of a thick-walled composite ring under the action of pressure

    No full text
    corecore