60 research outputs found

    Surface hydrogenation of oxygen terminated MXenes M2CO2 (M = Ti, V, Nb)

    Get PDF
    We have investigated reduction of MXenes M2CO2 (M = Ti, V, Nb) surface by hydrogen using density functional theory and statistical physics methods. We have approximated lateral interactions between adsorbed hydrogen with simple pairwise potential. We have confirmed model stability via cross-validation. Adsorption isotherms are calculated using Metropolis Monte Carlo method. We have built analytical Langmuir-like approximation of calculated isotherms. Ordered phases with 1/3 and 2/3 ML coverage are visually observed at low temperatures. At temperatures above 300 K no obvious plateau is observed, and intermediate phases does not exist. We compared adsorptive properties of MXenes at the same external conditions

    The influence of simulation equipment on the quality of learning hysteroscopy

    Get PDF
    Operative hysteroresectoscopy is encountered almost every day in the practice of obstetrician-gynecologists, however, there is a significant problem in the form of the impossibility of full-fledged training of this operation without potential harm to the patient. Modern simulation training equipment allows you to solve a wide range of data problems in the practical education of students and residents, making it possible to improve your level of skills within the framework of existing programs.Оперативная гистерорезектоскопия практически ежедневно встречается в практике акушер-гинекологов, однако, существует значительная проблема в виде невозможности полноценного обучения данной операции без наличия потенциального вреда пациенту. Современные симуляционное учебное оборудование позволяет решить широкий спектр данных задач в практическом образовании студентов и ординаторов, давая возможность в рамках существующих программ повышать свой уровень навыко

    Helically corrugated waveguide microwave pulse compression experiments

    Get PDF
    A high microwave pulse compressor based on a large diameter 5-fold helical waveguide structure was studied. The eigenwave dispersion was calculated using numerical and analytical techniques and compared with experimental measurements. The results of 5-fold helically corrugated waveguide microwave pulse compression experiments will be presented

    Разработка методики сравнительного анализа номенклатуры перечней лекарственных препаратов и ее применение для анализа перечней России, Англии и Италии

    Get PDF
    Objective: the development and approbation of the method for comparative analysis of the lists of medicines in different countries and systems of healthcare.Material and methods. Based on the open-access data on the lists of medicines published on official websites of the authorized regulators, the authors selected the national lists of medicines of Russia, England, and Italy for the development and approbation of the method. It was proposed to use three parameters: the absolute number of medicines by international nonproprietary name (INN); the structure of the lists based on anatomical therapeutic chemical (ATC) classification; and the coverage of the indications based on the International Classification of Diseases, 10th edition (ICD-10). The results of the analysis provided grounds for the review of the approaches to the formation of the lists of medicines required for medical help in Russia, England, and Italy and reimbursed from the state budget.Results. The number of medicines by INN in the national lists of England and Italy exceeds the total number of drugs included in the list of vital essential and desirable (VED) in Russia. All the analyzed lists were characterized by an uneven distribution of medicines within the lists by the ATC groups. The lists of medicines in England and Italy significantly exceed the list of VED by the number of the included medicines by all ATC groups excluding groups J and H in comparison with Italy, and groups J and V in comparison with England. At the same time, the list of VED significantly exceeds the list in England by the number of covered indications from the ATC L group. During the approbation, the method showed to be effective and can be used for further comparative studies of the national lists of medicines.Conclusion. Non-uniform lists of medicines by ATC-codes show that each country has priority areas in their healthcare systems. The list of VED can be shorter by the absolute number of the included medicines in England and Italy but it can exceed them by the coverage of indications due to peculiarities of the procedure of the list formation (reimbursement of medicines by all the registered indications). The results of the study with the proposed method can serve for the optimization of the VED list and the analysis of therapeutic areas that are undercovered.Цель: разработка и апробация методики сравнительного анализа перечней лекарственных препаратов (ЛП) различных стран и систем здравоохранения.Материал и методы. На основе открытой информации о составе перечней ЛП, размещенной в сети Интернет на официальных сайтах регуляторных органов, для разработки и апробации методики выбраны национальные перечни России, Англии и Италии. Предложено использовать три показателя: абсолютное число ЛП по международному непатентованному наименованию (МНН), структура перечней с точки зрения анатомо-терапевтическо-химической (АТХ) классификации и покрытие представленными ЛП показаний на основании кодов международной классификации болезней 10-го пересмотра. По результатам анализа проведен обзор подходов к формированию перечней ЛП для медицинского применения, необходимых для оказания медицинской помощи в России, и перечней ЛП Англии и Италии, возмещаемых за счет средств государственного бюджета.Результаты. Количество ЛП по МНН в перечнях Англии и Италии превышает общее число препаратов, включенных в перечень жизненно необходимых и важнейших лекарственных препаратов (ЖНВЛП) России. Для всех анализируемых перечней характерно неравномерное распределение ЛП по АТХ-группам. Перечни ЛП Англии и Италии значительно превосходят перечень ЖНВЛП по количеству включенных ЛП по всем классам АТХ за исключением классов J и H в сравнении с Италией и классов J и V в сравнении с Англией. При этом перечень ЖНВЛП значительно превосходит перечень Англии по количеству покрываемых показаний ЛП из класса L АТХ-классификации. В ходе апробации разработанная методика продемонстрировала свою эффективность и может быть использована для выполнения дальнейших сравнительных исследований перечней ЛП разных стран.Заключение. Неравномерность наполнения перечней по АТХ-кодам говорит о наличии в каждой стране приоритетных для системы здравоохранения направлений. Перечень ЖНВЛП, уступая по абсолютному количеству включенных ЛП перечням Англии и Италии, может превосходить их по количеству охватываемых показаний за счет особенности процедуры формирования перечней – возмещение ЛП по всем зарегистрированным показаниям. Результаты проведенного исследования с использованием разработанной методики могут служить для оптимизации перечня ЖНВЛП и анализа его на предмет терапевтических областей, которым не уделяется должного внимания

    Periodic GW level microwave pulses in X-band from a combination of a relativistic backward wave oscillator and a helical waveguide compressor

    Get PDF
    Backward Wave Oscillators (BWO's) utilizing moderately relativistic (550kV), high-current (10 kA) electron beams are capable of producing hundreds of MWs of pulsed radiation in the centimeter wavelength range. Such relativistic BWOs (RBWOs) allow for broadband, smooth, frequency-tuning via adjustment of the accelerating potential; making them an attractive source for use in frequency-swept pulse compression. This paper presents results of a 2.86m long 5-fold helically corrugated, dispersive pulse compressor where a maximum power compression ratio of 25 was achieved by compressing an input microwave pulse of 80 ns duration swept from 9.65 GHz to 9.05 GHz into a 1.6ns Gaussian-envelope pulse. For an average input power of 5.8 kW generated by a conventional traveling wave tube amplifier, a peak pulse output power of 145 kW was measured corresponding to an energy efficiency of 66%. An X-band relativistic BWO, designed to drive a 0.97m long 5-fold compressor, was built and tested using the accelerating potential generated by a SINUS-6 highcurrent accelerator. The experimental RBWO operated close to the predicted power of 700MW with its oscillation frequency varied from 10 to 9.6GHz via the falling edge of the voltage pulse. It was demonstrated that the 15ns duration frequency-swept part of the RBWO pulse was effectively compressed resulting in a 4.5-fold peak power increase with a maximum power of 3.2 GW generated. The potential for a 5-fold helical waveguide to compress longer duration pulses generated by a RBWO is discussed

    ELECTRIC MOTORS

    Get PDF
    corecore