155 research outputs found

    Lambda and Antilambda polarization from deep inelastic muon scattering

    Full text link
    We report results of the first measurements of Lambda and Antilambda polarization produced in deep inelastic polarized muon scattering on the nucleon. The results are consistent with an expected trend towards positive polarization with increasing x_F. The polarizations of Lambda and Antilambda appear to have opposite signs. A large negative polarization for Lambda at low positive x_F is observed and is not explained by existing models.A possible interpretation is presented.Comment: 9 pages, 2 figure

    Shadowing in Inelastic Scattering of Muons on Carbon, Calcium and Lead at Low XBj

    Full text link
    Nuclear shadowing is observed in the per-nucleon cross-sections of positive muons on carbon, calcium and lead as compared to deuterium. The data were taken by Fermilab experiment E665 using inelastically scattered muons of mean incident momentum 470 GeV/c. Cross-section ratios are presented in the kinematic region 0.0001 < XBj <0.56 and 0.1 < Q**2 < 80 GeVc. The data are consistent with no significant nu or Q**2 dependence at fixed XBj. As XBj decreases, the size of the shadowing effect, as well as its A dependence, are found to approach the corresponding measurements in photoproduction.Comment: 22 pages, incl. 6 figures, to be published in Z. Phys.

    Intra- A nd inter-observer reliability of anthropometric measurements and blood pressure in primary schoolchildren and adults: The Feel4Diabetes-study

    No full text
    Background: Feel4Diabetes was a large-scale, multicenter lifestyle intervention aiming to prevent type 2 diabetes among families from vulnerable population groups in six European countries (Belgium, Bulgaria, Finland, Greece, Hungary and Spain). The current study aimed to describe the process that was followed to harmonize and standardize the measurement of anthropometric (weight, height and waist circumference) and blood pressure (systolic and diastolic) indices, as well as to assess the intra- A nd inter-observer reliability of these measurements. Methods: A central training workshop was conducted prior to the baseline measurements of the Feel4Diabetes-intervention. One researcher from each intervention country, as well as 12 adults and 12 children (for the anthropometric measurements) and 21 adults (for the blood pressure measurements) participated in this workshop. Technical Error of Measurement (TEM) and reliability (%R) were calculated to assess the reliability of the indices which were assessed to evaluate the outcome of the Feel4Diabetes-intervention. The Feel4Diabetes-intervention is registered at http://clinicaltrials.gov/(NCT02393872). Results: Intra-observer reliability was found to be higher than 99.5% for all anthropometric measurements in both children and adults. Inter-observer reliability was found to be higher than 98% regarding the anthropometric measurements, while for blood pressure measurements %R was 76.62 and 91.38% for systolic and diastolic blood pressure measurements, respectively. Conclusion: The central training of the Fee4Diabetes-intervention ensured that the data collected for the outcome evaluation of the Feel4Diabetes-intervention in the six European countries at three different time points (baseline, follow-up 1 and follow-up 2) were valid and comparable. © 2020 The Author(s)

    Intra- A nd inter-observer reliability of anthropometric measurements and blood pressure in primary schoolchildren and adults: The Feel4Diabetes-study

    No full text
    Background: Feel4Diabetes was a large-scale, multicenter lifestyle intervention aiming to prevent type 2 diabetes among families from vulnerable population groups in six European countries (Belgium, Bulgaria, Finland, Greece, Hungary and Spain). The current study aimed to describe the process that was followed to harmonize and standardize the measurement of anthropometric (weight, height and waist circumference) and blood pressure (systolic and diastolic) indices, as well as to assess the intra- A nd inter-observer reliability of these measurements. Methods: A central training workshop was conducted prior to the baseline measurements of the Feel4Diabetes-intervention. One researcher from each intervention country, as well as 12 adults and 12 children (for the anthropometric measurements) and 21 adults (for the blood pressure measurements) participated in this workshop. Technical Error of Measurement (TEM) and reliability (%R) were calculated to assess the reliability of the indices which were assessed to evaluate the outcome of the Feel4Diabetes-intervention. The Feel4Diabetes-intervention is registered at http://clinicaltrials.gov/(NCT02393872). Results: Intra-observer reliability was found to be higher than 99.5% for all anthropometric measurements in both children and adults. Inter-observer reliability was found to be higher than 98% regarding the anthropometric measurements, while for blood pressure measurements %R was 76.62 and 91.38% for systolic and diastolic blood pressure measurements, respectively. Conclusion: The central training of the Fee4Diabetes-intervention ensured that the data collected for the outcome evaluation of the Feel4Diabetes-intervention in the six European countries at three different time points (baseline, follow-up 1 and follow-up 2) were valid and comparable. © 2020 The Author(s)

    Capsaicin — A Literature Survey

    No full text
    corecore