16 research outputs found

    Microbial Biosensors for Rapid Determination of Biochemical Oxygen Demand: Approaches, Tendencies and Development Prospects

    No full text
    One of the main indices of the quality of water is the biochemical oxygen demand (BOD). A little over 40 years have passed since the practical application of the first microbial sensor for the determination of BOD, presented by the Japanese professor Isao Karube. This time span has brought new knowledge to and practical developments in the use of a wide range of microbial cells based on BOD biosensors. At present, this field of biotechnology is becoming an independent discipline. The traditional BOD analysis (BOD5) has not changed over many years; it takes no less than 5 days to carry out. Microbial biosensors can be used as an alternative technique for assessing the BOD attract attention because they can reduce hundredfold the time required to measure it. The review examines the experience of the creation and practical application of BOD biosensors accumulated by the international community. Special attention is paid to the use of multiple cell immobilization methods, signal registration techniques, mediators and cell consortia contained in the bioreceptor. We consider the use of nanomaterials in the modification of analytical devices developed for BOD evaluation and discuss the prospects of developing new practically important biosensor models

    The Use of Diethoxydimethylsilane as the Basis of a Hybrid Organosilicon Material for the Production of Biosensitive Membranes for Sensory Devices

    No full text
    Biomembranes based on an organosilica sol–gel matrix were used to immobilize bacteria Paracoccus yeei VKM B-3302 as part of a biochemical oxygen demand (BOD) biosensor. Diethoxydimethylsilane (DEDMS) and tetraethoxysilane (TEOS) were used as precursors to create the matrix in a 1:1 volume ratio. The use of scanning electron microscopy (SEM) and the low-temperature nitrogen adsorption method (BET) showed that the sol–gel matrix forms a capsule around microorganisms that does not prevent the exchange of substrates and waste products of bacteria to the cells. The use of DEDMS as part of the matrix made it possible to increase the sensitivity coefficient of the biosensor for determining BOD by two orders of magnitude compared to a biosensor based on methyltriethoxysilane (MTES). Additionally, the long-term stability of the bioreceptor increased to 68 days. The use of such a matrix neutralized the effect of heavy metal ions on the microorganisms’ catalytic activity in the biosensor. The developed biosensor was used to analyze water samples from water sources in the Tula region (Russia)

    Preparation of Hybrid Sol-Gel Materials Based on Living Cells of Microorganisms and Their Application in Nanotechnology

    No full text
    Microorganism-cell-based biohybrid materials have attracted considerable attention over the last several decades. They are applied in a broad spectrum of areas, such as nanotechnologies, environmental biotechnology, biomedicine, synthetic chemistry, and bioelectronics. Sol-gel technology allows us to obtain a wide range of high-purity materials from nanopowders to thin-film coatings with high efficiency and low cost, which makes it one of the preferred techniques for creating organic-inorganic matrices for biocomponent immobilization. This review focuses on the synthesis and application of hybrid sol-gel materials obtained by encapsulation of microorganism cells in an inorganic matrix based on silicon, aluminum, and transition metals. The type of immobilized cells, precursors used, types of nanomaterials obtained, and their practical applications were analyzed in detail. In addition, techniques for increasing the microorganism effective time of functioning and the possibility of using sol-gel hybrid materials in catalysis are discussed

    Conductive Polymers and Their Nanocomposites: Application Features in Biosensors and Biofuel Cells

    No full text
    Conductive polymers and their composites are excellent materials for coupling biological materials and electrodes in bioelectrochemical systems. It is assumed that their relevance and introduction to the field of bioelectrochemical devices will only grow due to their tunable conductivity, easy modification, and biocompatibility. This review analyzes the main trends and trends in the development of the methodology for the application of conductive polymers and their use in biosensors and biofuel elements, as well as describes their future prospects. Approaches to the synthesis of such materials and the peculiarities of obtaining their nanocomposites are presented. Special emphasis is placed on the features of the interfaces of such materials with biological objects

    Journal of interferon & cytokine research

    No full text
    The methylotrophic Pichia angusta VKM Y-2559 and the oleaginous Cryptococcus curvatus VKM Y-3288 yeast cells were immobilized in a bimodal silica-organic sol-gel matrix comprised of tetraethoxysilane (TEOS), the hydrophobic additive methyltriethoxysilane (MTES) and the porogen polyethylene glycol (PEG). Under carefully optimized experimental conditions, employing basic catalysts, yeast cells have become the nucleation centers for a silica-organic capsule assembled around the cells. The dynamic process involved in the formation of the sol-gel matrix has been investigated using optical and scanning electron microscopic techniques. The results demonstrated the influence of the MTES composition on the nature of the encapsulation of the yeast cells, together with the architecture of the three-dimensional (3D) sol-gel biomatrix that forms during the encapsulation process. A silica capsule was found to form around each yeast cell when using 85. vol% MTES. This capsule was found to protect the microorganisms from the harmful effects that result from exposure to heavy metal ions and UV radiation. The encapsulated P. angusta BKM Y-2559 cells were then employed as a biosensing element for the detection of methanol. The P. angusta-based biosensor is characterized by high reproducibility (Sr, 1%) and operational stability, where the biosensor remains viable for up to 28 days

    A “2-in-1” Bioanalytical System Based on Nanocomposite Conductive Polymers for Early Detection of Surface Water Pollution

    No full text
    This work proposes an approach to the formation of receptor elements for the rapid diagnosis of the state of surface waters according to two indicators: the biochemical oxygen demand (BOD) index and toxicity. Associations among microorganisms based on the bacteria P. yeei and yeast S. cerevisiae, as well as associations of the yeasts O. polymorpha and B. adeninivorans, were formed to evaluate these indicators, respectively. The use of nanocomposite electrically conductive materials based on carbon nanotubes, biocompatible natural polymers—chitosan and bovine serum albumin cross-linked with ferrocenecarboxaldehyde, neutral red, safranin, and phenosafranin—has made it possible to expand the analytical capabilities of receptor systems. Redox polymers were studied by IR spectroscopy and Raman spectroscopy, the contents of electroactive components were determined by atomic absorption spectroscopy, and electrochemical properties were studied by electrochemical impedance and cyclic voltammetry methods. Based on the proposed kinetic approach to modeling individual stages of bioelectrochemical processes, the chitosan–neutral red/CNT composite was chosen to immobilize the yeast association between O. polymorpha (ks = 370 ± 20 L/g × s) and B. adeninivorans (320 ± 30 L/g × s), and a bovine serum albumin (BSA)–neutral composite was chosen to immobilize the association between the yeast S. cerevisiae (ks = 130 ± 10 L/g × s) and the bacteria P. yeei red/CNT (170 ± 30 L/g × s). After optimizing the composition of the receptor systems, it was shown that the use of nanocomposite materials together with associations among microorganisms makes it possible to determine BOD with high sensitivity (with a lower limit of 0.6 mg/dm3) and detect the presence of a wide range of toxicants of both organic and inorganic origin. Both receptor elements were tested on water samples, showing a high correlation between the results of biosensor analysis of BOD and toxicity and the results of standard analytical methods. The results obtained show broad prospects for creating sensitive and portable bioelectrochemical sensors for the early warning of environmentally hazardous situations based on associations among microorganisms and nanocomposite materials
    corecore