348 research outputs found

    Anticoagulation therapy and proximal femoral fracture treatment: An update

    Get PDF
    Hip fractures in the elderly population have become a ‘disease’ with increasing incidence. Most of the geriatric patients are affected by a number of comorbidities. Coagulopathies continue to be a special point of interest for the orthopaedic trauma surgeon, with the management of this high-risk group of patients a hot topic of debate among the orthopaedic community. While a universal consensus on how to manage thromboprophylaxis for this special cohort of patients has not been reached, multiple attempts to define a widely accepted protocol have been published

    Do Nonsteroidal Anti-Inflammatory Drugs Affect Bone Healing? A Critical Analysis

    Get PDF
    Nonsteroidal anti-inflammatory drugs (NSAIDs) play an essential part in our approach to control pain in the posttraumatic setting. Over the last decades, several studies suggested that NSAIDs interfere with bone healing while others contradict these findings. Although their analgesic potency is well proven, clinicians remain puzzled over the potential safety issues. We have systematically reviewed the available literature, analyzing and presenting the available in vitro animal and clinical studies on this field. Our comprehensive review reveals the great diversity of the presented data in all groups of studies. Animal and in vitro studies present so conflicting data that even studies with identical parameters have opposing results. Basic science research defining the exact mechanism with which NSAIDs could interfere with bone cells and also the conduction of well-randomized prospective clinical trials are warranted. In the absence of robust clinical or scientific evidence, clinicians should treat NSAIDs as a risk factor for bone healing impairment, and their administration should be avoided in high-risk patients

    Analysis of the compatibility of dental implant systems in fibula free flap reconstruction

    Get PDF
    As a result of major ablative surgery, head and neck oncology patients can be left with significant defects in the orofacial region. The resultant defect raises the need for advanced reconstruction techniques. The reconstruction in this region is aimed at restoring function and facial contour. The use of vascularised free flaps has revolutionised the reconstruction in the head and neck. Advances in reconstruction techniques have resulted in continuous improvement of oral rehabilitation. For example, endosteal implants are being used to restore the masticatory function by the way of prosthetic replacement of the dentition. Implant rehabilitation usually leads to improved facial appearance, function, restoration of speech and mastication. Suitable dental implant placement’s site requires satisfactory width, height and quality of bone. Reconstruction of hard tissue defects therefore will need to be tailored to meet the needs for implant placement. The aim of this feasibility study was to assess the compatibility of five standard commercially available dental implant systems (Biomet 3i, Nobel Biocare, Astra tech, Straumann and Ankylos) for placement into vascularised fibula graft during the reconstruction of oromandibular region. Radiographs (2D) of the lower extremities from 142 patients in the archives of the Department of Radiology in University College London Hospitals (UCLH) were analysed in this study. These radiographs were from 61 females and 81 males. Additionally, 60 unsexed dry fibular bones, 30 right sided, acquired from the collection of the Department of Anatomy, University College London (UCL) were also measured to account for the 3D factor. In the right fibula (dry bone), 90% of the samples measured had a width of 13.1 mm. While in the left fibula (dry bone), 90% of the samples measured had a width of 13.3 mm. Fibulas measured on radiographs had a width of 14.3 mm in 90% of the samples. The length ranges of the dental implants used in this study were: 7-13 mm (Biomet 3i), 10-13 mm (Nobel biocare), 8-13 mm (Astra Tech), 8-12 mm (Straumann ) and 8-11 mm (Ankylos). This study reached a conclusion that the width of fibula is sufficient for placement of most frequently used dental implants for oral rehabilitation after mandibular reconstructive procedures

    Timing of major fracture care in polytrauma patients – an update on principles, parameters and strategies for 2020

    Full text link
    Objectives Sustained changes in resuscitation and transfusion management have been observed since the turn of the millennium, along with an ongoing discussion of surgical management strategies. The aims of this study are threefold: a) to evaluate the objective changes in resuscitation and mass transfusion protocols undertaken in major level I trauma centers; b) to summarize the improvements in diagnostic options for early risk profiling in multiply injured patients and c) to assess the improvements in surgical treatment for acute major fractures in the multiply injured patient. Methods I. A systematic review of the literature (comprehensive search of the MEDLINE, Embase, PubMed, and Cochrane Central Register of Controlled Trials databases) and a concomitant data base (from a single Level I center) analysis were performed. Two authors independently extracted data using a pre-designed form. A pooled analysis was performed to determine the changes in the management of polytraumatized patients after the change of the millennium. II. A data base from a level I trauma center was utilized to test any effects of treatment changes on outcome. Inclusion criteria: adult patients, ISS > 16, admission < less than 24 h post trauma. Exclusion: Oncological diseases, genetic disorders that affect the musculoskeletal system. Parameters evaluated were mortality, ICU stay, ICU complications (Sepsis, Pneumonia, Multiple organ failure). Results I. From the electronic databases, 5141 articles were deemed to be relevant. 169 articles met the inclusion criteria and a manual review of reference lists of key articles identified an additional 22 articles. II. Out of 3668 patients, 2694 (73.4%) were male, the mean ISS was 28.2 (SD 15.1), mean NISS was 37.2 points (SD 17.4 points) and the average length of stay was 17.0 days (SD 18.7 days) with a mean length of ICU stay of 8.2 days (SD 10.5 days), and a mean ventilation time of 5.1 days (SD 8.1 days). Both surgical management and nonsurgical strategies have changed over time. Damage control resuscitation, dynamic analyses of coagulopathy and lactate clearance proved to sharpen the view of the worsening trauma patient and facilitated the prevention of further complications. The subsequent surgical care has become safer and more balanced, avoiding overzealous initial surgeries, while performing early fixation, when patients are physiologically stable or rapidly improving. Severe chest trauma and soft tissue injuries require further evaluation. Conclusions Multiple changes in management (resuscitation, transfusion protocols and balanced surgical care) have taken place. Moreover, improvement in mortality rates and complications associated with several factors were also observed. These findings support the view that the management of polytrauma patients has been substantially improved over the past 3 decades

    Does increased acetabular depth affect safe infra-acetabular screw placement in acetabular fracture fixation?

    Get PDF
    BACKGROUND Infra-acetabular screws enhance the fixation strength in acetabular fractures with separation of both columns. Placement without iatrogenic femoral head violation is challenging. PURPOSE To assess the impact of the acetabular configuration, the patients' age and gender on safe infra-acetabulum screw insertion. METHODS In 112 patients (69 females; mean age: 34 years, range 17-88; n = 200 hips), the lateral center-edge angle (LCE) was measured on radiographs. Using corresponding axial CT scans the residual distance from (the lateral border) of the screw to (the medial border of) the femoral head ("Screw-to-Femoral Head distance"; "RD_SFH") was determined. Statistical analysis was carried out using linear regression, multiple linear regression and normal distribution estimation. RESULTS The mean (range) LCE angle was 30° (7°-51°) and the mean (range) "RD_SFH" was 5 mm (1-14 mm). The linear regression model shows a significant linear relation between LCE and "RD_SFH" with a slope parameter of - 0.15 (p value < 0.0001), the Pearson correlation between LCE and "RD_SFH" is - 0.56 (CI [- 0.71, [- 0.40]). Age did not have a significant impact on the relation between LCE and "RD_SFH" (p value 0.85). Compared to male patients, in females, the intercept is 4.62 mm (p value 0.0005) less, the slope parameter is 0.09 (p value 0.029) larger. CONCLUSION The virtual possibility to place an infra-acetabular screw was given in all patients. An increasing depth of the acetabulum correlated with a decrease in residual distances. As hip joint cartilage thickness was not considered in measurements, intraoperative rule-out of screw mispositioning especially in deep acetabular sockets and females is still of utmost importance
    corecore