8,064 research outputs found

    Quantum complementarity of microcavity polaritons

    Get PDF
    We present an experiment that probes polariton quantum correlations by exploiting quantum complementarity. Specifically, we find that polaritons in two distinct idler-modes interfere if and only if they share the same signal-mode so that "which-way" information cannot be gathered. The experimental results prove the existence of polariton pair correlations that store the "which-way" information. This interpretation is confirmed by a theoretical analysis of the measured interference visibility in terms of quantum Langevin equations

    Two-loop Euler-Heisenberg effective actions from charged open strings

    Full text link
    We present the multiloop partition function of open bosonic string theory in the presence of a constant gauge field strength, and discuss its low-energy limit. The result is written in terms of twisted determinants and differentials on higher-genus Riemann surfaces, for which we provide an explicit representation in the Schottky parametrization. In the field theory limit, we recover from the string formula the two-loop Euler-Heisenberg effective action for adjoint scalars minimally coupled to the background gauge field.Comment: 32 pages, 3 eps figures, plain LaTeX. References added, minor changes to the text. Published version, affiliation correcte

    An Ultraluminous Supersoft X-ray Source in M81: An Intermediate-Mass Black Hole?

    Full text link
    Ultraluminous supersoft X-ray sources (ULSSS) exhibit supersoft spectra with blackbody temperatures of 50-100 eV and bolometric luminosities above 103910^{39} erg s1^{-1}, and are possibly intermediate mass black holes (IMBHs) of 103M\ge10^3 M_\odot or massive white dwarfs that are progenitors of type Ia supernovae. In this letter we report our optical studies of such a source in M81, M81-ULS1, with HST archive observations. M81-ULS1 is identified with a point-like object, the spectral energy distribution of which reveals a blue component in addition to the companion of an AGB star. The blue component is consistent with the power-law as expected from the geometrically-thin accretion disk around an IMBH accretor, but inconsistent with the power-law as expected from the X-ray irradiated flared accretion disk around a white dwarf accretor. This result is strong evidence that M81-ULS1 is an IMBH instead of a white dwarf.Comment: 12 pages, 1 table, 3 figure

    Status of the EDELWEISS-II experiment

    Full text link
    EDELWEISS is a direct dark matter search experiment situated in the low radioactivity environment of the Modane Underground Laboratory. The experiment uses Ge detectors at very low temperature in order to identify eventual rare nuclear recoils induced by elastic scattering of WIMPs from our Galactic halo. We present results of the commissioning of the second phase of the experiment, involving more than 7 kg of Ge, that has been completed in 2007. We describe two new types of detectors with active rejection of events due to surface contamination. This active rejection is required in order to achieve the physics goals of 10-8 pb cross-section measurement for the current phase

    Emergence of entanglement from a noisy environment: The case of polaritons

    Get PDF
    We show theoretically that polariton pairs with a high degree of polarization entanglement can be produced through parametric scattering. We demonstrate that it can emerge in coincidence experiments, even at low excitation densities where the dynamics is dominated by incoherent photoluminesce. Our analysis is based on a microscopic quantum statistical approach that treats coherent and incoherent processes on an equal footing, thus allowing for a quantitative assessment of the amount of entanglement under realistic experimental conditions. This result puts forward the robustness of pair correlations in solid-state devices, even when noise dominates one-body correlations.Comment: revised version. new figure

    Intense terahertz pulses from SPARC-LAB coherent radiation source

    Get PDF
    The linac-based Terahertz source at the SPARC_LAB test facility is able to gene rate highly intense Terahertz broadband pulses via coherent transition radiation (CTR) from high brightness electron beams. The THz pulse duration is typically down to 100 fs RMS and can be tuned through the electron bunch duration and shaping. The measured stored energy in a single THz pulse has reached 40 μ J, which corresponds to a peak electric field of 1.6 MV/cm at the THz focus. Here we present the main features, in particular spatial and sp ectral distributions and energy characterizations of the SPARC_LAB THz source, which is very competitive for investigations in Condensed Matter, as well as a valid tool for electron beam longitudinal diagnostics

    Field quantization in inhomogeneous anisotropic dielectrics with spatio-temporal dispersion

    Get PDF
    A quantum damped-polariton model is constructed for an inhomogeneous anisotropic linear dielectric with arbitrary dispersion in space and time. The model Hamiltonian is completely diagonalized by determining the creation and annihilation operators for the fundamental polariton modes as specific linear combinations of the basic dynamical variables. Explicit expressions are derived for the time-dependent operators describing the electromagnetic field, the dielectric polarization and the noise term in the latter. It is shown how to identify bath variables that generate the dissipative dynamics of the medium.Comment: 24 page

    Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: optimization of oil extraction method and analytical characterization

    Get PDF
    A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio samples that entry in the European register of the products with P.D.O. In the present study the SPE procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision of the full analytical procedure was satisfactory and the mean recoveries were 92.8 + 0.3 % and 96.6 + 0.1 % for 25 and 50 mg L-1 level of addition, respectively. Selected chromatographic conditions allowed a very fast squalene determination; in fact it was well separated in ~ 0.54 min with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels ranged from 55.45 to 226.34 mg . kg-1. Comparing our results with those of other studies it emerges that squalene contents in P.D.O. Sicilian pistachio samples, generally, were higher than those measured for other samples of different geographic origins
    corecore