8,064 research outputs found
Quantum complementarity of microcavity polaritons
We present an experiment that probes polariton quantum correlations by
exploiting quantum complementarity. Specifically, we find that polaritons in
two distinct idler-modes interfere if and only if they share the same
signal-mode so that "which-way" information cannot be gathered. The
experimental results prove the existence of polariton pair correlations that
store the "which-way" information. This interpretation is confirmed by a
theoretical analysis of the measured interference visibility in terms of
quantum Langevin equations
Two-loop Euler-Heisenberg effective actions from charged open strings
We present the multiloop partition function of open bosonic string theory in
the presence of a constant gauge field strength, and discuss its low-energy
limit. The result is written in terms of twisted determinants and differentials
on higher-genus Riemann surfaces, for which we provide an explicit
representation in the Schottky parametrization. In the field theory limit, we
recover from the string formula the two-loop Euler-Heisenberg effective action
for adjoint scalars minimally coupled to the background gauge field.Comment: 32 pages, 3 eps figures, plain LaTeX. References added, minor changes
to the text. Published version, affiliation correcte
An Ultraluminous Supersoft X-ray Source in M81: An Intermediate-Mass Black Hole?
Ultraluminous supersoft X-ray sources (ULSSS) exhibit supersoft spectra with
blackbody temperatures of 50-100 eV and bolometric luminosities above
erg s, and are possibly intermediate mass black holes (IMBHs) of
or massive white dwarfs that are progenitors of type Ia
supernovae. In this letter we report our optical studies of such a source in
M81, M81-ULS1, with HST archive observations. M81-ULS1 is identified with a
point-like object, the spectral energy distribution of which reveals a blue
component in addition to the companion of an AGB star. The blue component is
consistent with the power-law as expected from the geometrically-thin accretion
disk around an IMBH accretor, but inconsistent with the power-law as expected
from the X-ray irradiated flared accretion disk around a white dwarf accretor.
This result is strong evidence that M81-ULS1 is an IMBH instead of a white
dwarf.Comment: 12 pages, 1 table, 3 figure
Status of the EDELWEISS-II experiment
EDELWEISS is a direct dark matter search experiment situated in the low
radioactivity environment of the Modane Underground Laboratory. The experiment
uses Ge detectors at very low temperature in order to identify eventual rare
nuclear recoils induced by elastic scattering of WIMPs from our Galactic halo.
We present results of the commissioning of the second phase of the experiment,
involving more than 7 kg of Ge, that has been completed in 2007. We describe
two new types of detectors with active rejection of events due to surface
contamination. This active rejection is required in order to achieve the
physics goals of 10-8 pb cross-section measurement for the current phase
Emergence of entanglement from a noisy environment: The case of polaritons
We show theoretically that polariton pairs with a high degree of polarization
entanglement can be produced through parametric scattering. We demonstrate that
it can emerge in coincidence experiments, even at low excitation densities
where the dynamics is dominated by incoherent photoluminesce. Our analysis is
based on a microscopic quantum statistical approach that treats coherent and
incoherent processes on an equal footing, thus allowing for a quantitative
assessment of the amount of entanglement under realistic experimental
conditions. This result puts forward the robustness of pair correlations in
solid-state devices, even when noise dominates one-body correlations.Comment: revised version. new figure
MESENCHYMAL STEM CELLS IN PH-NEGATIVE MYELOPROLIFERATIVE NEOPLASMS: IDLE OBSERVERS OR PART OF THE DISEASE?
Intense terahertz pulses from SPARC-LAB coherent radiation source
The linac-based Terahertz source at the SPARC_LAB test facility is able to gene
rate highly intense Terahertz broadband
pulses
via
coherent transition radiation (CTR) from high brightness electron beams. The THz pulse duration is typically
down to 100 fs RMS and can be tuned through the electron bunch duration and shaping. The measured stored energy in a
single THz pulse has reached 40
μ
J, which corresponds to a peak
electric field of 1.6 MV/cm at the THz focus. Here we
present the main features, in particular spatial and sp
ectral distributions and energy
characterizations of the
SPARC_LAB THz source, which is very competitive for investigations in Condensed Matter, as well as a valid tool for
electron beam longitudinal diagnostics
Field quantization in inhomogeneous anisotropic dielectrics with spatio-temporal dispersion
A quantum damped-polariton model is constructed for an inhomogeneous
anisotropic linear dielectric with arbitrary dispersion in space and time. The
model Hamiltonian is completely diagonalized by determining the creation and
annihilation operators for the fundamental polariton modes as specific linear
combinations of the basic dynamical variables. Explicit expressions are derived
for the time-dependent operators describing the electromagnetic field, the
dielectric polarization and the noise term in the latter. It is shown how to
identify bath variables that generate the dissipative dynamics of the medium.Comment: 24 page
Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: optimization of oil extraction method and analytical characterization
A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio
samples that entry in the European register of the products with P.D.O. In the present study the SPE
procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision
of the full analytical procedure was satisfactory and the mean recoveries were 92.8 + 0.3 % and
96.6 + 0.1 % for 25 and 50 mg L-1 level of addition, respectively. Selected chromatographic
conditions allowed a very fast squalene determination; in fact it was well separated in ~ 0.54 min
with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels
ranged from 55.45 to 226.34 mg . kg-1. Comparing our results with those of other studies it emerges
that squalene contents in P.D.O. Sicilian pistachio samples, generally, were higher than those
measured for other samples of different geographic origins
- …
