932 research outputs found

    Deterministic single-atom excitation via adiabatic passage and Rydberg blockade

    Full text link
    We propose to use adiabatic rapid passage with a chirped laser pulse in the strong dipole blockade regime to deterministically excite only one Rydberg atom from randomly loaded optical dipole traps or optical lattices. The chirped laser excitation is shown to be insensitive to the random number \textit{N} of the atoms in the traps. Our method overcomes the problem of the N\sqrt {N} dependence of the collective Rabi frequency, which was the main obstacle for deterministic single-atom excitation in the ensembles with unknown \textit{N}, and can be applied for single-atom loading of dipole traps and optical lattices.Comment: 6 pages, 5 figures. Version 5 is expanded and submitted to PRA. Typo in Fig.4 corrected in Version 2. Version 3 and 4 are duplicates of V

    Topological dragging of solitons

    Full text link
    We put forward properties of solitons supported by optical lattices featuring topological dislocations, and show that solitons experience attractive and repulsive forces around the dislocations. Suitable arrangements of dislocations are even found to form soliton traps, and the properties of such solitons are shown to crucially depend on the trap topology. The uncovered phenomenon opens a new concept for soliton control and manipulation, e.g., in disk-shaped Bose-Einstein condensates.Comment: 15 pages, 5 figures, to appear in Physical Review Letter

    SPATIO-TEMPORAL PARAMETERS AND INSTANTANEOUS VELOCITY OF SPRINT RUNNING USING A WEARABLE INERTIAL MEASUREMENT UNIT

    Get PDF
    INTRODUCTION: Wearable inertial measurement units (IMU) provide movement-related data without any space limitation or cumbersome setup. They can be proficiently used to perform an in-field biomechanical analysis of sprint running providing information useful for performance optimisation and injury prevention. Mechanical key quantities characterizing sprint running performance are instantaneous velocity and displacement of the athlete (Cavagna et al., 1971). However, the process of determining velocity and position by numerical integration of acceleration is jeopardized by the noise characterizing the signal of micro-machined accelerometers (Thong et al., 2002). The aim of this study was to compensate these errors by reducing the integration interval, taking advantage of a priori known laws of motion, and by cyclically determining the initial conditions of the integration process, in order to yield reliable spatio-temporal parameters during sprint running. METHODS: A male subject (26 yrs, 73 kg, 1.73 m) performed 7 in-lab sprints, starting from a standing position. Due to limited lab volume (12*9*4 m) only the first 3 steps were considered. 3D linear acceleration and orientation of a wearable IMU positioned on the upper back trunk (MTx, Xsens; m=30g) were collected and the following parameters were estimated over each cycle: 1) stance time (ST); 2) centre of mass progression displacement (d); 3) variation of vertical and progression velocity (Δvv, Δvp). Reference data were obtained as follows: ST from a contact-sensitive mat (stance 1) and two force platforms (Bertec) (stance 2-3); Δv and d from stereophotogrammetry (Vicon MX, Plug-in-Gait protocol). The average of the absolute percentage difference (eabs%=|(reference-inertial)*100/reference|), referred to as error (e%), was calculated for each parameter. RESULTS: Reference and sensor estimates and percentage error are reported in Table 1. DISCUSSION AND CONCLUSION: The obtained Δv percentage errors are consistent with respect to the literature (Vetter et al., 2008). Even though these errors still increase at each stance phase, the methodology is sensitive to the variations of velocity determined by the reference measurement system. As regards ST and d, no similar previous study has been reported. However since the methodology relies on the identification of foot contact timings for reducing the integration interval, small errors in the determination of these parameters, are encouraging. Future developments concern in-field sprint running experimental sessions

    Spatial nonlocal pair correlations in a repulsive 1D Bose gas

    Get PDF
    We analytically calculate the spatial nonlocal pair correlation function for an interacting uniform 1D Bose gas at finite temperature and propose an experimental method to measure nonlocal correlations. Our results span six different physical realms, including the weakly and strongly interacting regimes. We show explicitly that the characteristic correlation lengths are given by one of four length scales: the thermal de Broglie wavelength, the mean interparticle separation, the healing length, or the phase coherence length. In all regimes, we identify the profound role of interactions and find that under certain conditions the pair correlation may develop a global maximum at a finite interparticle separation due to the competition between repulsive interactions and thermal effects.Comment: Final published version, modified titl

    THE TRUNK ORIENTATION DURING SPRINT START ESTIMATED USING A SINGLE INERTIAL SENSOR

    Get PDF
    Sprint start and block acceleration are two very important phases which could determine the result of a sprint. Tellez & Doolittle (1984) showed that these two phases account for 64% of the total result for a 100m sprint. Sprinters have to move from a crouch to a standing position, trying to reach their maximal velocity as fast as possible. Many authors have delved into the biomechanical factors concerning both phases (Fortier et al., 2005; Harland & Steele, 1997; Schot & Knutzen, 1992). Trunk orientation is considered by coaches one of the key elements in moving from the crouch to the upright position, however only a few studies focused specifically on this parameter (Čoh et al., 1998; Čoh et al., 2006; Natta et al., 2006). Moreover, the experimental setups used in the latter studies are quite cumbersome and limited in terms of acquisition volume (motion capture systems, high-speed cameras or optical contact time meters), therefore, they are hardly usable during everyday training sessions. Wearable inertial measurement units (IMU), that embed 3D linear acceleration and angular rate sensors (accelerometers and gyroscopes), can be effectively used to perform in-field biomechanical analysis of sprint running, providing information useful for performance optimisation and injury prevention. In particular, IMUs provide an estimate of body segment rotations relative to an inertia system of reference with one axis oriented as the gravitational field. The aim of this pilot study is to validate the use of a single IMU to estimate the trunk orientation angle in the progression plane during a sprint start from the blocks

    ROUNDHOUSE KICK WITH AND WITHOUT IMPACT IN KARATEKA OF DIFFERENT TECHNICAL LEVEL

    Get PDF
    The purpose of this study was to compare two different Karate roundhouse kicks performed by athletes of different technical level. The combination of high movement velocities and a high technical difficulty, qualify these actions as a good model to quantify the ability of a Karateka to execute complex movements. The first kick, directed to the face, entails a strong braking action to avoid the impact (NI), the other, directed to the chest, is concluded by an impact (IM). Technical aspects and the role of muscular co-activation as joint protector were investigated in six top level Karateka (KA) and six practicing karate amateurs (CO), by estimating joint kinematics and neuromuscular activity patterns. KA presented a faster execution for both tasks, prevalently due to a faster knee extension, supported by a low co-activation of the antagonist Biceps Femoris. This behaviour confirms that elite KA tend to lower the co-activation of antagonist muscles during fast movements, partially in contrast with the antagonists possible role in maintaining knee stability. The NI task, requiring higher technical competence and entailing a high target, is performed by KA athletes using a peculiar technique, based on a wide hip flexion-extension range, with a peak hip ab-adduction occurring earlier than in CO. A lower co-activation presented by CO during knee flexion is presumably due to their difficulty in mastering this complex kick

    Vacuum Solutions of Einstein's Equations in Parabolic Coordinates

    Full text link
    We present a simple method to obtain vacuum solutions of Einstein's equations in parabolic coordinates starting from ones with cylindrical symmetries. Furthermore, a generalization of the method to a more general situation is given together with a discussion of the possible relations between our method and the Belinsky-Zakharov soliton-generating solutions.Comment: 15 pages, version published in Class. Quantum Gra

    Vestibular rehabilitation training in patients with subacute stroke: a preliminary randomized controlled trial

    Get PDF
    Background: Vestibular rehabilitation (VR) consists in a customized exercise program patient-centred that includes a combination of different exercise components with the aim to promote gaze stability, improve balance and gait, and facilitate somatosensory integration. OBJECTIVE: The aim of this study was to investigate the effect of customized vestibular rehabilitation training on gait stability of patients with subacute stroke. METHODS: Twenty-five inpatients (12 M, age: 64.1±12.1 years) with diagnosis of subacute stroke were enrolled and randomized in two groups. All patients were evaluated before and after 4 weeks of training sessions. An instrumented 10-Meter Walk Test together with traditional clinical scales were used to assess VR effects. To investigate if any fall event occurred after patients' dismissal, they were followed-up at three and twelve months after dismissal. RESULTS: Higher values of walking speed and stride length were observed in the VR group. Conversely, no significant difference was found in terms of trunk stability. The results of between-group comparison highlight significant differences between the two groups for different clinical scale scores. CONCLUSION: VR could be included into a rehabilitation program for patients with stroke for improving their gait and dynamic balance acting on their vestibular system as facilitator of recovery

    Matter-wave soliton control in optical lattices with topological dislocations

    Get PDF
    We address the concept of guiding and transporting matter-wave solitons along the channels of optical lattices made by interference patterns of beams containing topological wavefront dislocations. The local lattice distortions that occur around the dislocations cause solitons to move along reconfigurable paths, a phenomenon that may be used for controlled all-optical manipulation of Bose-Einstein condensates. Multiple dislocations form traps that can capture and hold moving solitons.Comment: 15 pages, 4 figures, to appear in Physical Review

    Evaluation of the severity of chronic hepatitis C with 3-T 1H-MR spectroscopy

    Get PDF
    OBJECTIVE. The purpose of this study was to compare the spectral characteristics of lipids, choline-containing compounds, and glutamine-glutamate complex assessed with H-1-MR spectroscopy with the histologic findings in patients with chronic hepatitis C. SUBJECTS AND METHODS. Nine healthy controls and 30 patients with biopsy-proven hepatitis C virus-related liver disease participated in this prospective study. Degree of fibrosis and histologic activity were scored according to the METAVIR classification. The percentage of involved hepatocytes was used to grade steatosis. Hepatic spectra were obtained with a 3-T spectroscopic system. Tenfold cross-validated stepwise discriminant analysis was performed to classify disease severity on the basis of the spectroscopic findings. RESULTS. There was a strong correlation between H-1-MR spectroscopically measured lipid concentration and the degree of steatosis at histologic examination (r=0.9236, p < 0.0001). This finding enabled clear separation of groups according to degree of histologically determined steatosis. Variation in lipid concentration was consistent with the degree of steatosis (r=0.7265, p < 0.0001) and stage of fibrosis (r=0.8156, p < 0.0001). In univariate analysis, concentrations of both choline-containing compounds and glutamine-glutamate complex had a direct correlation with histologic grade ( p < 0.0001) and degree of steatosis ( p < 0.0001) but not with stage of fibrosis ( p > 0.05). In multivariate analysis, the only factor independently associated with concentrations of choline-containing compounds and glutamine-glutamate complex was histologic grade. In cross-validated discriminant analysis based on choline-containing compound, glutamine-glutamate complex, and lipid resonance, 70% ( 21 of 30) of the histologic grade groups and 73% (22 of 30) of the steatosis groups were correctly classified. CONCLUSION. Hydrogen-1 MR spectroscopy can be an alternative to liver biopsy in the evaluation of steatosis and necroinflammatory activity in liver disease but is not useful for complete evaluation of hepatic fibrosis
    • …
    corecore