    Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam

    Get PDF
    This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15¿mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in scanning mode is challenging. A transmission chamber was attached to the lower part of the collimators and used for percentage depth dose (PDD) and profile measurements in scanning mode with a stereotactic diode. Tissue-maximum ratios (TMR) and output factors (OF) for all collimators were measured with a stereotactic diode (IBA). TMR and the OF for the largest collimator were also acquired on a polystyrene phantom with a microionization chamber of 0.016¿cm3 volume (PTW Freiburg PinPoint 3D). Measured TMR with diode and PinPoint microionization chamber agreed very well with differences smaller than 1% for depths below 20¿cm, except for the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. OF measured with diode and chamber showed a difference of 3.5%. The use of a transmission chamber allowed the measurement of the small-field dosimetric properties with a simple setup. The commissioning of radiosurgery cones in FFF beams has been performed with essentially the same procedures and recommended ..

    Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam

    No full text
    This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15¿mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in scanning mode is challenging. A transmission chamber was attached to the lower part of the collimators and used for percentage depth dose (PDD) and profile measurements in scanning mode with a stereotactic diode. Tissue-maximum ratios (TMR) and output factors (OF) for all collimators were measured with a stereotactic diode (IBA). TMR and the OF for the largest collimator were also acquired on a polystyrene phantom with a microionization chamber of 0.016¿cm3 volume (PTW Freiburg PinPoint 3D). Measured TMR with diode and PinPoint microionization chamber agreed very well with differences smaller than 1% for depths below 20¿cm, except for the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. OF measured with diode and chamber showed a difference of 3.5%. The use of a transmission chamber allowed the measurement of the small-field dosimetric properties with a simple setup. The commissioning of radiosurgery cones in FFF beams has been performed with essentially the same procedures and recommended ..

    Automated whole slide image analysis for a translational quantification of liver fibrosis.

    No full text
    Current literature highlights the need for precise histological quantitative assessment of fibrosis which cannot be achieved by conventional scoring systems, inherent to their discontinuous values and reader-dependent variability. Here we used an automated image analysis software to measure fibrosis deposition in two relevant preclinical models of liver fibrosis, and established correlation with other quantitative fibrosis descriptors. Longitudinal quantification of liver fibrosis was carried out during progression of post-necrotic (CCl-induced) and metabolic (HF-CDAA feeding) models of chronic liver disease in mice. Whole slide images of picrosirius red-stained liver sections were analyzed using a fully automated, unsupervised software. Fibrosis was characterized by a significant increase of collagen proportionate area (CPA) at weeks 3 (CCl) and 8 (HF-CDAA) with a progressive increase up to week 18 and 24, respectively. CPA was compared to collagen content assessed biochemically by hydroxyproline assay (HYP) and by standard histological staging systems. CPA showed a high correlation with HYP content for CCl (r = 0.8268) and HF-CDAA (r = 0.6799) models. High correlations were also found with Ishak score or its modified version (r = 0.9705) for CCl and HF-CDAA (r = 0.9062) as well as with NASH CRN for HF-CDAA (r = 0.7937). Such correlations support the use of automated digital analysis as a reliable tool to evaluate the dynamics of liver fibrosis and efficacy of antifibrotic drug candidates in preclinical models
    corecore