22 research outputs found

    International Consensus Based Review and Recommendations for Minimum Reporting Standards in Research on Transcutaneous Vagus Nerve Stimulation (Version 2020).

    Get PDF
    Given its non-invasive nature, there is increasing interest in the use of transcutaneous vagus nerve stimulation (tVNS) across basic, translational and clinical research. Contemporaneously, tVNS can be achieved by stimulating either the auricular branch or the cervical bundle of the vagus nerve, referred to as transcutaneous auricular vagus nerve stimulation(VNS) and transcutaneous cervical VNS, respectively. In order to advance the field in a systematic manner, studies using these technologies need to adequately report sufficient methodological detail to enable comparison of results between studies, replication of studies, as well as enhancing study participant safety. We systematically reviewed the existing tVNS literature to evaluate current reporting practices. Based on this review, and consensus among participating authors, we propose a set of minimal reporting items to guide future tVNS studies. The suggested items address specific technical aspects of the device and stimulation parameters. We also cover general recommendations including inclusion and exclusion criteria for participants, outcome parameters and the detailed reporting of side effects. Furthermore, we review strategies used to identify the optimal stimulation parameters for a given research setting and summarize ongoing developments in animal research with potential implications for the application of tVNS in humans. Finally, we discuss the potential of tVNS in future research as well as the associated challenges across several disciplines in research and clinical practice

    How might acupuncture work? A systematic review of physiologic rationales from clinical trials

    Get PDF
    BACKGROUND: Scientific interest in acupuncture has led numerous investigators to conduct clinical trials to test the efficacy of acupuncture for various conditions, but the mechanisms underlying acupuncture are poorly understood. METHODS: The author conducted a PubMed search to obtain a fair sample of acupuncture clinical trials published in English in 2005. Each article was reviewed for a physiologic rationale, as well as study objectives and outcomes, experimental and control interventions, country of origin, funding sources and journal type. RESULTS: Seventy-nine acupuncture clinical trials were identified. Twenty-six studies (33%) offered no physiologic rationale. Fifty-three studies (67%) posited a physiologic basis for acupuncture: 33 (62% of 53) proposed neurochemical mechanisms, 2 (4%) segmental nervous system effects, 6 (11%) autonomic nervous system regulation, 3 (6%) local effects, 5 (9%) effects on brain function and 5 (9%) other effects. No rationale was proposed for stroke; otherwise having a rationale was not associated with objective, positive or negative findings, means of intervention, country of origin, funding source or journal type. The dominant explanation for how acupuncture might work involves neurochemical responses and is not reported to be dependent on treatment objective, specific points, means or method of stimulation. CONCLUSION: Many acupuncture trials fail to offer a meaningful rationale, but proposing a rationale can help investigators to develop and test a causal hypothesis, choose an appropriate control and rule out placebo effects. Acupuncture may stimulate self-regulatory processes independent of the treatment objective, points, means or methods used; this would account for acupuncture's reported benefits in so many disparate pathologic conditions

    On the question of optimization of mutual influence of channels for receiving of information and channels of antenna self-direction operating on the basic information signal

    No full text
    At use of mirror aerials mutual influence of channels of reception of the information and channels of self-direction can be shown through mutual communication of the irradiators, taking place in a near zone of each one, and through elements of microwave devices realizing total-differentiated processing, etc. In the work the optimization of the circuit is considered in view of minimization of mutual influence of channels of reception of the information and the channels of self-direction operating on the basic information signal

    On a problem of implementation of monopulse self-steering on an information signal

    No full text
    The most widespread ways of guidance of antenna system on a space vehicle (SV) provide for usage of additional equipment (radio beacon) onboard of space vehicle that reduces in additional expending of its power resources. In the paper it is offered to abandon GPS receiver and transmitter of a radio beacon at the expense of usage of improved antenna system, which ensures its self-steering on a signal of an information channel in a monopulse mode. It is offered to use for this aim a multimirror antenna system as large module antenna consisting of 4 not rotationally symmetric mirror antennas, which allow one to provide reliability of the useful information receiving with desired quality
    corecore