899 research outputs found
Intrabeam Scattering Analysis of ATF Beam Measurements
At the Accelerator Test Facility (ATF) at KEK intrabeam scattering (IBS) is a
strong effect for an electron machine. It is an effect that couples all
dimensions of the beam, and in April 2000, over a short period of time, all
dimensions were measured as functions of current. In this report we derive a
simple relation for the growth rates of emittances due to IBS. We apply the
theories of Bjorken-Mtingwa, Piwinski, and a formula due to Raubenheimer to the
ATF parameters, and find that the results all agree (if in Piwinski's formalism
we replace the dispersion squared over beta by the dispersion invariant).
Finally, we compare theory, including the effect of potential well bunch
lengthening, with the April 2000 measurements, and find reasonably good
agreement in the energy spread and horizontal emittance dependence on current.
The vertical emittance measurement, however, implies that either: there is
error in the measurement (equivalent to an introduction of 0.6% x-y coupling
error), or the effect of intrabeam scattering is stronger than predicted (35%
stronger in growth rates).Comment: 4 pages, 3 figures, Presented at IEEE Particle Accelerator Conferenc
Yang-Mills fields on CR manifolds
We study pseudo Yang-Mills fields on a compact strictly pseudoconvex CR
manifold.Comment: 52 page
Principal Component Analysis of Cavity Beam Position Monitor Signals
Model-independent analysis (MIA) methods are generally useful for analysing
complex systems in which relationships between the observables are non-trivial
and noise is present. Principle Component Analysis (PCA) is one of MIA methods
allowing to isolate components in the input data graded to their contribution
to the variability of the data. In this publication we show how the PCA can be
applied to digitised signals obtained from a cavity beam position monitor
(CBPM) system on the example of a 3-cavity test system installed at the
Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA
based method can be used to extract beam position information, and matches
conventional techniques in terms of performance, while requiring considerably
less settings and data for calibration
A new design of nanocrystalline silicon optical devices based on 3-dimensional photonic crystal structures
We propose a new design of nanocrystalline silicon optical devices which are based on control of electromagnetic fields, electronic states, as well as the phonon dispersion of size-controlled silicon quantum dots
Complete genome sequence of microcystis aeruginosa FD4, isolated from a subtropical river in Southwest Florida
We report the first complete genome of Microcystis aeruginosa from North America. A harmful bloom that occurred in the Caloosahatchee River in 2018 led to a state of emergency declaration in Florida. Although strain FD4 was isolated from this toxic bloom, the genome did not have a microcystin biosynthetic gene cluster
- …