897 research outputs found

    Intrabeam Scattering Analysis of ATF Beam Measurements

    Get PDF
    At the Accelerator Test Facility (ATF) at KEK intrabeam scattering (IBS) is a strong effect for an electron machine. It is an effect that couples all dimensions of the beam, and in April 2000, over a short period of time, all dimensions were measured as functions of current. In this report we derive a simple relation for the growth rates of emittances due to IBS. We apply the theories of Bjorken-Mtingwa, Piwinski, and a formula due to Raubenheimer to the ATF parameters, and find that the results all agree (if in Piwinski's formalism we replace the dispersion squared over beta by the dispersion invariant). Finally, we compare theory, including the effect of potential well bunch lengthening, with the April 2000 measurements, and find reasonably good agreement in the energy spread and horizontal emittance dependence on current. The vertical emittance measurement, however, implies that either: there is error in the measurement (equivalent to an introduction of 0.6% x-y coupling error), or the effect of intrabeam scattering is stronger than predicted (35% stronger in growth rates).Comment: 4 pages, 3 figures, Presented at IEEE Particle Accelerator Conferenc

    Principal Component Analysis of Cavity Beam Position Monitor Signals

    Full text link
    Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied to digitised signals obtained from a cavity beam position monitor (CBPM) system on the example of a 3-cavity test system installed at the Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA based method can be used to extract beam position information, and matches conventional techniques in terms of performance, while requiring considerably less settings and data for calibration

    A new design of nanocrystalline silicon optical devices based on 3-dimensional photonic crystal structures

    No full text
    We propose a new design of nanocrystalline silicon optical devices which are based on control of electromagnetic fields, electronic states, as well as the phonon dispersion of size-controlled silicon quantum dots

    Complete genome sequence of microcystis aeruginosa FD4, isolated from a subtropical river in Southwest Florida

    Get PDF
    We report the first complete genome of Microcystis aeruginosa from North America. A harmful bloom that occurred in the Caloosahatchee River in 2018 led to a state of emergency declaration in Florida. Although strain FD4 was isolated from this toxic bloom, the genome did not have a microcystin biosynthetic gene cluster
    • …
    corecore